NTIS 바로가기비파괴검사학회지 = Journal of the Korean Society for Nondestructive Testing, v.28 no.1 = no.105, 2008년, pp.16 - 24
김현 (서강대학교 물리학과 바이오융합 연구단) , 김송희 (서강대학교 물리학과 바이오융합 연구단) , 김주영 (서강대학교 물리학과 바이오융합 연구단) , 이기진 (서강대학교 물리학과 바이오융합 연구단)
Near-field scanning microwave microscope (NSMM) has been used to characterize the electromagnetic properties of samples based on a cavity perturbation technique. We used a NSMM using a waveguide cavity to couple a metallic probe tip as a point like evanescent field emitter. We explained the quality ...
R. S. Aga, S. Yan, Y. Xie, S. Han and J. Z. Wu, 'Microwave surface resistance of $HgBa_2CaCu_2O_{6+\delta}$ thin films,' Appl. Phys. Lett. Vol. 76, No. 12, pp. 1606-1608, (2000)
M. M. Mola, J. T. King, C. P. McRaven and S. Hill, 'Josephson plasma resonance in $k-(BEDT-TTF)_2Cu(NCS)_2$ ,' Phys. Rev. B., Vol. 62, No. 9, pp. 5965-5970, (2000)
H. Kitano, R. Matsuo, K. Miwa, A. Maeda, T. Takenobu, Y. Iwasa and T. Mitani, 'Evidence for insulating behavior in the electric conduction of $(NH_3)K_3C_{60}$ systems,' Phys. Rev. Lett., Vol. 88, No. 9, pp. 096401-096404, (2002)
J. D. Kokales, P. Fouriner, L. V. Mercaldo, V. V. Talanov, R. L. Greene and S. M. Anlage, 'Microwave electrodynamics of electron-doped cuprate superconductors,' Phys. Rev. Lett., Vol. 85, No. 17, pp. 3696-3699, (2000)
E. A. Ash and G. Nicholls, 'Super-resolution aperture scanning microscope,' Nature, Vol. 237, pp. 510-512, (1972)
T. P. Budka, S. D. Waclawik and G. M. Rebeiz, 'A coaxial 0.5-18GHz near electric field measurement system for planar microwave circuits using integrated probes,' IEEE Trans. Microwave Theory & Tech., Vol. 44, No. 12(1), pp. 2174-2184, (1996)
S. Hong, J. Kim, W. Park and K. Lee, 'Improved surface imaging with a near-field scanning microwave microscope using a tunable resonator,' Appl. Phys. Lett., Vol. 80, No. 3, pp. 524-526, (2002)
M. Tabib-Azar, D. Akinwande, G. Ponchak and S. R. Clair, 'Novel physical sensors using evanescent microwave probes,' Rev. Sci. Instrum., Vol. 70, No. 8, pp. 3381-3386, (1999)
W. Park, J. Kim and K. Lee, 'Millimeter-wave scanning near-field microscope using a resonant waveguide probe,' Appl. Phys. Lett., Vol. 79, No. 16, pp. 2642-2644, (2001)
Grant R. Fowles, Introduction to Modern Optics, Dover, NY, (1975)
David. K. Cheng, Field and Wave Electromagnetics, Prentice Hall, NY, (1989)
D. M. Pozar, Microwave Engineering, Wiley, NY, (1990)
J. D. Jackson, Classical Electrodynamics, John Wiley & Sons, NY, (1998)
J. S. Hyde, R. R. Mett and J. R. Anderson, 'Cavities with axially uniform fields for use in electron paramagnetic resonance. III. re-entrant geometries,' Rev. Sci. Instrum., Vol. 73, No. 11, pp. 4003-4009, (2002)
M. Ohtsu, 'Near-field nano/atom optics and technology,' Springer-Verlag, Tokyo, (1998)
A. F. Lann, M. Abu-teir, M. Golosovsky amd D. Davidov, 'A cryogenic microwave scanning near-field probe: application to study of high-Tc superconductors,' Rev. Sci. Instrum., Vol. 70, No. 11, pp. 4348-4355 (1999)
S. Kim, H. Yoo, A. Babajanyan, J. Kim and K. Lee, 'A study for a near-field microwave microscope using a tuning fork distance control system in liquid environment,' Journal of the Korean Society for Nondestructive Testing, Vol. 27, No. 4, pp. 339-347, (2007)