NTIS 바로가기핵의학 분자영상 = Nuclear medicine and molecular imaging, v.42 no.2, 2008년, pp.137 - 144
이병일 (전남대학교병원 핵의학과)
Positron emission tomography-computed tomography (PET/CT) provides both functional and anatomical images of high quality non-invasively with better precision in localization than PET alone. Increase in the use of PET/CT, coupled with increasing concerns about the quality of medical services accrued ...
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
International Electrotechnical Comission. International standard (IEC 61675-1). Radionuclide imaging devices characteristics and test conditions. Part 1: Positron emission tomographs. International Electrotechnical Comission. 1998
American College of Radiology. ACR technical standard for medical nuclear physics performance monitoring of PET imaging equipment. ACR technical standard(PET equiment):847-9, 2001
AAPM publication. AAPM report no.39. Specification and acceptance testing of computed tomography scanners. 1993
American College of Radiology. ACR technical standard for medical nuclear physics performance monitoring of computed tompgraphy (CT) equipment. ACR technical standard(PET equiment):831-33, 2002
International Electrotechnical Comission. International standard (IEC 1223-2-6). Evaluation and routine testing in medical imaging department - Part 2-6: Constancy test - X-ray equipment for computed tompgraphy International Electrotechnical Comission. 1994
International Electrotechnical Comission. International standard (IEC 1223-3-5). Evaluation and routine testing in medical imaging department - Part 3-5: Acceptance tests - Imaging performance of computed tompgraphy X-ray equipment International Electrotechnical Comission. 2004
International Electrotechnical Comission. International standard (IEC 1223-3-5). Evaluation and routine testing in medical imaging department - Part 3-6: Acceptance tests - Imaging performance of computed tompgraphy X-ray equipment International Electrotechnical Comission. 2004
National Electrical Manufacturers Association. NEMA Standard Publication NU 2-1994. Performance measurements of positron emission tomographs. National Electrical Manufacturers Association, 1994
National Electrical Manufacturers Association. NEMA Standard Publication NU 2-2001. Performance measurements of positron emission tomographs. National Electrical Manufacturers Association, 2001
Choi Y, Chung J-K, Report of research service project (Development of standard of evaluation of PET). 식품의약품안정청. 2003
Choi JG, Choi CW, Lee BI, Report of research service project (Research for actual conditions of quality assurance of imaging system in nuclear medicine). 식품의약청안정청. 2007
Karp J.S., Daube-Witherspoon M.E., Hoffman E.J. et al, Performance standards in positron emission tomography. J Nucl Med 1991;32: 2342-50
Daube-Witherspoon M.E., Karp J.S, Casey M.E., et al. PET performance measurements using the NEMA NU 2-2001 standard. J Nucl Med 2002;43:1398-409
Spinks T, Jones T, Heather J, et al. Quality control procedures in positron tomography. Eur J Nucl Med 1989;15:736-40
Buchert R, Bohuslavizki KH, Mester J, et al. Quality assurance in PET: Evaluation of the clinical relevance of detector defects, J Nucl Med 1999;10:1657-65
Mawlawi O., Podoloff D.A., Kohlmyer S., et al. Performance characteristics of a newly developed PET/CT scanner using NEMA standards in 2D and 3D modes. J Nucl Med 2004;45:1734-42
Siemens Medical Solutions. Operator's guide biograph 6 Hi-Rez, Hofmann Estates. Siemens Medical Solutions., 2004
Siemens Medical Solutions. Installation manual biograph 6 Hi-Rez, Hofmann Estates. Siemens Medical Solutions., 2004
GE Medical Systems. Technical publication: AdvanceTM PET imaging system description and specification. Milwaukee, GE Medical Systems, 1994
GE Medical Systems. Technical publication: Discovery LS PET CT combined PET and CT scanner operator's guide. Milwaukee, GE Medical Systems, 1994
GE Medical Systems. DST PET-CT NEMA Test procedures. Applicable to Discovery ST. Milwaukee, GE Medical Systems, 2005
Philips Medical System. Gemini GXL performance test technical manual, Cleveland, Philips Medical Systems, 2005
Philips Medical System. Gemini calibration technical manual for dual, 16 power, and GSL, Cleveland, Philips Medical Systems, 2006
Kim JS, Lee JS, Lee DS, Chung J-K, Lee MC. Performance evaluation of Siemens CTI ECAT EXACT 47 scanner using NEMA NU2-2001. Korean J Nucl Med 2004;38:259-67
Lee JR, Choi Y, Choe YS, Lee KH, Kim SE, Shin SA, Kim BT. Performance measurements of positron emission tomography: An Investigation using general electric advanceTM. Korean J Nucl Med 1996;30:548-59
Jeong HK, Kim HJ, Son HK, Bong JK, Jung HA, Jeon TJ, Kim JS, Lee JD, Yoo HS. Standard performance measurements of GE advance positron emission tomography. Korean J Nucl Med 2001;35: 100-12
Kim JS, Lee JS, Lee BI, Lee DS, Chung J-K, Lee MC. Performance characteristics of 3D GSO PET/CT scanner(Philips GEMINI PET/CT). Korean J Nucl Med 2004;38:318-24
MacFarlane CR. ACR Accreditation of Nuclear Medicine and PET Imaging Departments. J Nucl Med Technol 2006;34:18-24
Wackers FJ 3rd. Intersocietal commission for the accreditation of nuclear medicine laboratories. Blueprint of the accreditation program of the intersocietal commission for the accreditation of nuclear medicine laboratories. J Nucl Cardiol 1999;6:372-4
Katanick SL. Fundamentals of ICANL Accreditation. J Nucl Med Technol 2005;33:19-23
※ AI-Helper는 부적절한 답변을 할 수 있습니다.