NTIS 바로가기비파괴검사학회지 = Journal of the Korean Society for Nondestructive Testing, v.30 no.4 = no.120, 2010년, pp.380 - 385
The integrity of components and piping of operating nuclear power plants has been identified by in-service inspection(ISI) requirements and activities commensurate with standards and codes such as KEPIC MI or ASME Code Section XI. However, the other various degradation mechanisms not considered duri...
P. L. Andersen et al. : Expert Panel Report on Proactive Materials Degradation Assessment, NUREG/CR-6923, Brookhaven National Laboratory (2007)
NEI 97-06 : Steam Generator Program Guidelines, Nuclear Energy Institute (2005)
S. Swilley : Steam Generator Management Program: Pressurized Water Reactor Steam Generator Examination Guidelines (Rev. 7), EPRI Report-1013706 (2007)
USNRC Generic Letter 2006-01 : Steam Generator Tube Integrity and Associated Technical Specification, NRC Website, www.nrc.gov (2006)
USNRC Information Notice 2005-09 : Indications on Thermally Treated Alloy 600 Steam Generator Tubes and Tubeto-Tubesheet Welds, NRC Website, www.nrc.gov (2005)
USNRC Information Notice 2004-17 : Loose Part Detection and Computerized Eddy Current Data Analysis in Steam Generator, NRC Website, www.nrc.gov (2004)
특정기술 주제보고서: 증기발생기 관리프로그램 통합지침 (Rev. 1), 한국수력원자력(주), (2008)
USNRC Fact Sheet : Improvement Resulting from Davis-Besse Incident, NRC Website, www.nrc.gov (2009)