NTIS 바로가기설비공학논문집 = Korean journal of air-conditioning and refrigeration engineering, v.23 no.1, 2011년, pp.1 - 7
차동안 (한국생산기술연구원 에너지설비센터) , 권오경 (한국생산기술연구원 에너지설비센터) , 윤재호 (한국생산기술연구원 에너지설비센터)
The performance of louver-finned flat-tube and fin and tube radiators for computer CPU liquid cooling was experimentally investigated. In this study, 7 samples of radiators with different shape and pass number (1, 2, 10) were tested in a wind tunnel. The experiments were conducted under the differen...
Hanamann, R. J., 1981, Microelectronic device thermal resistance: A format for standardardization, Heat Transfer in Electronic Equipment (ASME HTD-20), pp. 39-48.
Kwon, O. K., Choi, M. J., Cha, D. A., and Yun, J H., 2008, A study on thermal performance of micro channel water block for computer CPU cooling, Transaction of the KSME, Vol. 32, No. 10, pp. 776-783.
Schmidt, R., 2000, Low temperature electronic cooling, Electronics Cooling, Vol. 6, No.3, pp. 1-7.
Cho, J P., Oh, W. K., Kim, N. H., and Youn, B., 2002, Air-side performance of louver-finned flat aluminum heat exchangers at a low velocity region, Transactions of the KSME, Vol. 26, No. 12, pp. 1681-1691.
Kim, M. H. and Bullard, C. W., 2002, Air-side thermal hydraulic performance of multi-louvered fin aluminum heat exchangers, International Journal of Refrigeration, Vol. 25, pp. 390-400.
Tang, L. H., Zeng, M., Xie, G. N., and Wang, Q. W., 2009, Fin pattern effects on air side heat transfer and friction characteristics of fin-and-tube heat exchangers with large number of large-diameter tube rows, Heat Transfer Engineering, Vol. 30, pp. 171-180.
Holman, J. P., 2000, Experimental Method for Engineer, 7th ed., McGraw-Hill, pp. 51-60.
Mills, A. F., 1995, Basic Heat and Mass Transfer, Irwin, Chicago, pp. 233-243.
Shah, R. K., 1985, Compact heat exchangers in handbook of heat transfer applications, Rohsenow, W. M., Hartnett, J. P., Ganic, E. N. eds., pp. 181-200.