최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기대한방사선종양학회지 = The Journal of the Korean soceity for therapeutic radiology and oncology, v.29 no.2, 2011년, pp.99 - 106
김성진 (을지대학교 의과대학 을지대학교병원 방사선종양학교실) , 이미조 (을지대학교 의과대학 을지대학교병원 방사선종양학교실) , 윤선민 (을지대학교 의과대학 을지대학교병원 방사선종양학교실)
Purpose: To analyze our quality assurance (QA) data for intensity modulated radiation therapy (IMRT) according to treatment site and to possibly improve QA for IMRT in Hospital. Materials and Methods: We performed QA on 50 patients (head and neck, 28 patients; Breast, 14 patients; Pelvis, 8 patients...
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
Xing L, Chen GT. Iterative methods for inverse treatment planning. Phys Med Biol 1996;41:2107-2123
Bortfeld T, Boyer AL, Schlegel W, Kahler DL, Waldron TJ. Realization and verification of three-dimensional conformal radiotherapy with modulated fields. Int J Radiat Oncol Biol Phys 1994;30:899-908
Chui CS, LoSasso T, Spirou S. Dose calculation for photon beams with intensity modulation generated by dynamic jaw or multileaf collimations. Med Phys 1994;21:1237-1244
Bortfeld T. IMRT: a review and preview. Phys Med Biol 2006;51:R363-R379
Shin KH, Park SY, Park DH, et al. Patient specific quality assurance of IMRT: quantitative approach using film dosimetry and optimization. J Korean Soc Ther Radiol Oncol 2005;23:176-185
Yoon SM, Yi BY, Choi EK, Kim JH, Ahn SD, Lee SW. Quality assurance of patients for intensity modulated radiation therapy. J Korean Soc Ther Radiol Oncol 2002;20:81-90
Cho BC, Park SW, Oh DH, Bae H. Quality assurance for intensity modulated radiation therapy. J Korean Soc Ther Radiol Oncol 2001;19:275-286
Vieira SC, Kaatee RS, Dirkx ML, Heijmen BJ. Two-dimensional measurement of photon beam attenuation by the treatment couch and immobilization devices using an electronic portal imaging device. Med Phys 2003;30:2981-2987
Low DA, Harms WB, Mutic S, Purdy JA. A technique for the quantitative evaluation of dose distributions. Med Phys 1998;25:656-661
Low DA, Mutic S, Dempsey JF, et al. Quantitative dosimetric verification of an IMRT planning and delivery system. Radiother Oncol 1998;49:305-316
Low DA, Dempsey JF. Evaluation of the gamma dose distribution comparison method. Med Phys 2003;30:2455-2464
Depuydt T, Van Esch A, Huyskens DP. A quantitative evaluation of IMRT dose distributions: refinement and clinical assessment of the gamma evaluation. Radiother Oncol 2002;62:309-319
Park DH, Shin D, Park SY, et al. Optimized matching of film dosimetry with calculated doses for IMRT quality assurance. Phys Med 2007;23:49-57
Ezzell GA, Burmeister JW, Dogan N, et al. IMRT commissioning: multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119. Med Phys 2009;36:5359-5373
Kaurin DG, Maryanski MJ, Duggan DM, Morton KC, Coffey CW. Use of MRI based polymer gel dosimetry, pelvic phantom, and cirtyal simulation to verify set-up and calculated three-dimensional dose distribution for a prostate treatment. In: Proceedings of the 1st International Workshop on Radiation Therapy Gel Dosimetry; Lexington, KY, USA; 1999. 184-186
Mayer R, Williams A, Frankel T, et al. Two-dimensional film dosimetry application in heterogeneous materials exposed to megavoltage photon beams. Med Phys 1997;24:455-460
Que W, Kung J, Dai J. 'Tongue-and-groove' effect in intensity modulated radiotherapy with static multileaf collimator fields. Phys Med Biol 2004;49:399-405
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
출판사/학술단체 등이 한시적으로 특별한 프로모션 또는 일정기간 경과 후 접근을 허용하여, 출판사/학술단체 등의 사이트에서 이용 가능한 논문
※ AI-Helper는 부적절한 답변을 할 수 있습니다.