박희정 (Biomedical Engineering, Konkuk University) , 이영재 (Biomedical Engineering, Konkuk University) , 이재호 (Biomedical Engineering, Konkuk University) , 임민규 (Biomedical Engineering, Konkuk University) , 김경남 (Biomedical Engineering, Konkuk University) , 강승진 (Biomedical Engineering, Konkuk University) , 이정환 (Dept. of Biomedical Engineering, Konkuk University)
A robust new algorithm for R wave detection named for Multiscale-based Peak Detection(MSPD) is assessed in this paper using MIT/BIH Arrhythmia Database. MSPD algorithm is based on a matrix composed of local maximum and find R peaks using result of standard deviation in the matrix. Furthermore, By re...
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
핵심어 | 질문 | 논문에서 추출한 답변 |
---|---|---|
다중스케일 기반 피크검출 알고리즘은 무엇인가? | 본 논문에서 제안하는 다중스케일 기반 피크검출 알고리즘은 Felix Scholkmann[1] 등에 의하여 처음으로 제안된 방법으로, 대상 신호에서 국지적 최대값 스칼로그램(scalogram)을 계산하여 피크 성분이 있는 곳의 위치를 확률적으로 파악한 뒤, 최종적으로 피크의 위치는 스칼로그램의 표준편차가 최소가 된다는 점을 이용해 피크를 검출하는 알고리즘이다. | |
일반적으로 사용되고 있는 피크 검출 방법로는 어떤 것들이 있는가? | 생체신호처리 분야에서 신호의 피크를 검출하는 과정은 오프라인에서 후처리를 위해서도 매우 중요하므로 여러 가지 새로운 방법들이 끊임없이 개발되고 있다. 일반적으로 사용되고 있는 피크 검출 방법에는 대표적으로 역치값 설정 기술(Adaptive threshold)[3], 미분(Differentiation)[8], 웨이블렛 변환(Wavelet transform)[2], 힐버트 변환(Hilbert transform)[11] 등을 바탕으로 하는 알고리즘들이 있다. 하지만 이 알고리즘들은 신호를 분석하기 전에 상황에 따라서 많은 변수들(역치값[3] 또는 윈도우 길이[4])을 상황에 맞게 수정해야 하는 문제점을 가지고 있다. | |
심전도의 한 주기를 구성하는 P, Q, R, S, T파는 각각 어떤 작용에 의해 발생하는가? | 심전도의 한 주기(Cycle)는 각각 P, Q, R, S, T파(wave)로 구성되어 있다. P파는 심방의 탈분극, QRS파는 좌, 우심실의 탈분극, T파는 심실의 재분극에 의해 각각 발생한다. 일반적으로 심전도 신호는 호흡 및 전원 장치로 인하여 신호에 왜곡 현상이 나타난다. |
Felix Scholkmann, "An Efficient Algorithm for Automatic Peak Detection in Noisy Periodic and Quasi-Periodic Signals", MDPI, 5, pp. 588-603, 2012
Li C, Zheng C, Tai C, "Detection of ECG characteristic points using wavelet transforms", IEEE, 42, pp. 21-28, 1995
Jacobsen, A.L., "Auto-Threshold peak detection in physiological signals", IEEE, 3, pp. 2094-2195, 2001
G. Palshikar, "Simple algorithms for peak detection in time-series." Proc. 1st Int. Conf. Advanced Data Analysis, Business Analytics and Intelligence, 2009
Miri Ha, Hyuk Lee and Byonghyo Shim, "R peak detection based on weighted biorthogonal spline wavelet transform in ECG signal." Conference on Information and Control Systems, pp. 91-92, 2009
THAKOR, N. V., WEBSTER, J. G., TOMPKINS, W. J., "Optimal QRS detector", Medical and Biological Engineering, 21, pp. 343-350, 1983
CHEN, H. C., CHEN, S. W., "A moving average based filtering system with its application to real-time QRS detection", Computers in Cadiology, pp. 585-588, 2003
PAN, J. & TOMPKINS, W. J., "A Real-Time QRS Detection Algorithm", Biomedical Engineering, IEEE Transactions on, BME, 32, pp. 230-236, 1985
CUIWEI, L., CHONGZUN, Z., CHANGFENG, T., "Detection of ECG characteristic points using wavelet transforms", Biomedical Engineering, IEEE Transactions on, 42, pp. 21-28, 1995
J.S. Sahambi, S.N. Tandon, and R.K.P. Bhatt, "Using wavelet transforms for ECG characterization", An on-line digital signal processing system. Engineering in Medicine and Biology Magazine, IEEE, 16, pp. 77-83, 1997
D. S. Benitez, "A new QRS detection algorithm based on the Hilbert transform", Computers in Cardiology, 27, pp. 379-382, 2000
J. Moraes, M. Freitas, F. Vilani, and E. Costa, "A QRS complex detection algorithm using electrocardiogram leads", Computers in Cardiology, 29, pp. 205-208, 2002
MAHMOODABADI, S. Z., AHMADIAN, A., ABOLHASANI, M. D., "ECG Feature Extraction Using Daubechies Wavelets", In : Proceedings of the Fifth IASTED International Conference Visualization, Imaging, and Image Processing, pp. 343-348, 2005
DS BENITEZ, PA GAYDECKI, A ZAIDI, AP FITZPATRICK, "A New QRS Detection Algorithm Based on the Hilbert Transform", IEEE Computers in Cardiology, 27, pp. 379-382, 2000
Etienne Aliot, Remi Nitzsche, Alain Ripart, "Arrhythmia detection by dual-chamber implantable cardioverter defibrillators", Europace, 6, 4, pp.273-286, 2004
PATRICK S. HAMILTON and WILLIS J. TOMPKINS, "Quantitative Investigation of QRS Detection Rules Using the MIT/BIH Arrhythmia Database", IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, vol. BME-33, no. 12, 1986
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
※ AI-Helper는 부적절한 답변을 할 수 있습니다.