최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기전기학회논문지 = The Transactions of the Korean Institute of Electrical Engineers, v.64 no.5, 2015년, pp.792 - 798
오한별 (Dept. of Biomedical Engineering, BK21 Plus Research Institute of Biomedical Engineering, College of Biomedical and Health Science, Konkuk University) , 김지선 (Dept. of Biomedical Engineering, BK21 Plus Research Institute of Biomedical Engineering, College of Biomedical and Health Science, Konkuk University) , 김아희 (Dept. of Biomedical Engineering, BK21 Plus Research Institute of Biomedical Engineering, College of Biomedical and Health Science, Konkuk University) , 고봉준 (Dept. of Biomedical Engineering, BK21 Plus Research Institute of Biomedical Engineering, College of Biomedical and Health Science, Konkuk University) , 김준식 (Dept. of Biomedical Engineering, BK21 Plus Research Institute of Biomedical Engineering, College of Biomedical and Health Science, Konkuk University) , 이은숙 (Dept. of Biomedical Engineering, BK21 Plus Research Institute of Biomedical Engineering, College of Biomedical and Health Science, Konkuk University) , 최주현 (Dept. of Biomedical Engineering, BK21 Plus Research Institute of Biomedical Engineering, Colle) , 전재훈
Joint angle generally can be measured to check the recovery process in rehabilitation field. This paper suggests to measure joint angle with Infrared sensor based on triangulation principle. We performed various experiments to find the optimal condition of the sensor’s attached distance, heig...
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
K. J. O’Donovan, R. Kamnik, D. T. O’Keeffe, and G. M.m Lyons, “An inertial and magnetic sensor based technique for joint angle measurement,” Journal of biomechanics, vol. 40, no. 12, pp. 2604-2611, 2007.
B. G. Steele, B. Belza, K. Cain, C. Warms, J. Coppersmith, J. Howard, “Bodies in motion: Monitoring daily activity and exercise with motion sensors in people with chronic pulmonary disease,” Journal of Rehabilitation Research and Development, vol. 40, no. 5, pp. 45-58, 2003.
C. Mancuso, G. De Toma, and R. Paradiso, “Wearable Electrogoniometer for Knee Joint Parameters Capture,” In Converging Clinical and Engineering Research on Neurorehabilitation, vol. 1, pp. 1055-1059, 2013.
A. A. Mohamed, J. Beyea, J. Landry, C. A. McGibbon, A. Sexton, and J. Baba, “Comparison of Strain-Gage and Fiber-Optic Goniometry for Measuring Knee Kinematics During Activities of Daily Living and Exercise,” Journal of biomechanical engineering, vol. 134, no. 8, 2012.
J. Cruse, "Constraints for Joint Angle Control of the Human Arm," Biological Cybernetics, vol. 54, no. 2, pp. 125-132, 1986.
S. E. Gu, W. J. Lee, and S. J. Lee, “An analysis of the anaerobic power and joint angle of the lower limbs in relation to seat height and pedal cleat location on a bicycle,” The Korea Journal of Sports Science, vol. 22, no. 2, pp. 1349-1359, 2013.
C. A. Yucesoy, F. Ates, U. Akgun, and M. Karahan, “Measurement of human gracilis muscle isometric forces as a function of knee angle, intraoperatively,” Journal of Biomechanics, vol. 43, no. 14, pp. 2665-2671, 2010.
V. Debur, T. Arkhipova, G. Beskin, M. Pakhomov, V. Plokhotnichenko, M. Smirnova, and A. Solinc, "Position-sensitive detector for the 6-m optical telescope," Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol. 513, no. 1-2, pp. 127-131, Nov. 2003.
G. I. Jung, J. S. Kim, T. H. Lee, J. H. Choi, H. B. Oh, A. H. Kim, G. M. Eom, J. H. Lee, S. C. Chung, J. R. Park, Y. J. Lee, H. J. Park, and J. H. Jun, “Development of an Optical Fiber Sensor for Angular Displacement Measurements,” Bio-Medical Materials and Engineering, vol. 24, no. 1, pp.771-780, 2014.
American Academy of Orthopaedic Surgeons, “Joint motion: Method of measuring and recording,” Edinburgh : Churchill Livingstone., 2011.
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
※ AI-Helper는 부적절한 답변을 할 수 있습니다.