Ryu, Jae-ho (Department of Interdisciplinary Program in Biomedical Engineering, Pusan National University) , Huh, Jung-Bo (Department of Prosthodontics, School of Dentistry, Dental Research Institute, Pusan National University Dental Hospital, Pusan National University) , Ro, Jung-Hoon (Department of Interdisciplinary Program in Biomedical Engineering, Pusan National University) , Yun, Mi-Jung (Department of Prosthodontics, School of Dentistry, Dental Research Institute, Pusan National University Dental Hospital, Pusan National University) , Jeong, Chang-Mo (Department of Prosthodontics, School of Dentistry, Dental Research Institute, Pusan National University Dental Hospital, Pusan National University)
PURPOSE: The aim of this study was to evaluate the influence of the oxide layer removal process in the Co-Cr-Mo (CCM) abutment after casting procedure on the prosthesis settlement and screw stability. MATERIALS AND METHODS: CCM abutments of four different interface conditions (CCM-M; machined, CCM-O...
Adell R, Eriksson B, Lekholm U, Br?nemark P, Jemt T. A long-term follow-up study of osseointegrated implants in the treatment of totally edentulous jaws. Int J Oral Maxillofac Implants 1990;5:347-59.
Adell R, Lekholm U, Rockler B, Br?nemark P. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg 1981;10:387-416.
Henry PJ, Laney WR, Jmet T, Harris D, Krogh PHJ, Polizzi G, Zarb GA, Hewwmann I. Osseointegrated implants for single-tooth replacement: A prospective 5-year multicenter styudy. Int J Oral Maxillofac Implants 1996;11:450-55.
Lekholm U, Grondahl K, Jmet T. Outcome of oral implant treatment in partially edentulous jaws followed 20 years in clinical function. Clin Oral Implants Res 2006;8:178-86.
Jomeus L, Jmet T, Carlsson L. Loads and designs of screw joints for single crowns supported by osseointegrated implants. Int J Oral Maxillofac Implants 1992;7:353-59.
Kim KS, Lim YJ, Kim MJ, Kwon HB, Yang JH, Lee JB, Yim SH. Variation in the total lengths of abutment/implant assemblies generated with a function of applied tightening torque in external and internal implant-abutment connection. Clin Oral Implants Res 2011;22:834-39.
Michalakis KX, Hirayama H, Garefis PD. Cement-retained versus screw-retained implant restorations: A critical review. Int J Oral Maxillofac Implants 2003;18:719-28.
Lewis S, Beumer J, Moy P. The "UCLA" abutment. Int J Oral Maxillofac Implants 1988;3:183-89.
Barbosa G, Simamoto Junior P, Fernandes neto A, Mattos M, Neves F. Prosthetic laboratory influence on the vertical misfit at the implant/UCLA abutment interface. Braz Dent J 2007;18(2): 139-43.
Binon P, Mchuge M. The effect of elinimating implant/abutment rotational misfit on screw joint stability. Int J Prosthodont 1996;9:511-19.
Duncan A, Labeed H, Abel L, Kamali A, Watts F. Effects of thermal treatments on protein adsorption of Co-Cr-Mo ASTM- F75 alloys. J Master Sci;Master Med 2011;22:1455-464.
Caicedo S, Desai R, McAllister K, Reddy A, Jacobs J, Hallab J. Soluble and particulate Co-Cr-Mo alloy implant metals activate the inflammasome danger signaling pathway in human macrophages: A novel mechanism for implant debris reactivity. J Orthop Res 2009;27:847-54.
Proussaefs P, Lozada J. Evaluation of two Vitallium blade- form implants retrieved after 13 to 21 years of function: A clinical report. J Prosthet Dent 2002;87:412-17.
Teigen K, Jokstad A. Dental implant suprastructures using cobalt-chromium alloy compared with gold alloy framework veneered with ceramic or acrylic resin : a retrospective cohort study up to 18 years. Clin Oral Implant Res 2012;23:853-60.
Kenneth J. Philllips' science of dental materials. 11th ed. Charm yun. Co., 2003, korean Ver., p. 336-7, p. 575-6.
Stuker RA, Teixeira ER, Beck JC, da Costa NP. Preload and torque removal evaluation of three different abutment screw for single standing implant restoration. J Appl Oral Sci 2008;16(1): 55-8.
Shin HM, Jung CM, Jeon YC, Yun MJ, Yoon JH. Influence of tightening torque on implant-abutment screw joint stability. J Korean Acad Prosthodont 2008;46:396-408.
해당 논문의 주제분야에서 활용도가 높은 상위 5개 콘텐츠를 보여줍니다.
더보기 버튼을 클릭하시면 더 많은 관련자료를 살펴볼 수 있습니다.
※ AI-Helper는 부적절한 답변을 할 수 있습니다.