Objectives: Exposure to airborne bacteria is associated with adverse health effects such as respiratory and infectious diseases. This study evaluated airborne bacterial concentrations in the living rooms, kitchens, and toilets of 30 homes. Methods: Bacteria were sampled with an MAS100 impactor in th...
Objectives: Exposure to airborne bacteria is associated with adverse health effects such as respiratory and infectious diseases. This study evaluated airborne bacterial concentrations in the living rooms, kitchens, and toilets of 30 homes. Methods: Bacteria were sampled with an MAS100 impactor in three spaces in the subject homes between April 2014 and February 2015. Bacteria were grown on TSA plates for 48 hours at $35^{\circ}C$. The bacterial strains were isolated and amplified by polymerase chain reaction. Results: The most culturable bacteria were found in toilets ($624.0CFU/m^3$, GM: $417.3CFU/m^3$), followed by in the kitchen ($503.8CFU/m^3$, GM: $324.9CFU/m^3$). The dominant genera identified were: Staphylococcus sp.(19%), Micrococcus sp.(16%), and Bacillus sp.(11%) in the indoor air and Bacillus sp. (30%) in the outdoor air. Gram-positive bacteria comprised more than half of all colonies. Conclusion: In this study, culturable bacteria concentrations were higher than those reported in other spaces. Therefore, it is important to control relative humidity and remove moisture to prevent bacteria from multiplying. Additionally, the dominant species in indoor air were Staphylococcus sp. and Micrococcus sp. These are found on the human skin, mucous membranes, and hair, so human activity can affect bacterial distribution. Therefore, cleaning and controlling moisture are important for reducing indoor bacterial concentrations.
Objectives: Exposure to airborne bacteria is associated with adverse health effects such as respiratory and infectious diseases. This study evaluated airborne bacterial concentrations in the living rooms, kitchens, and toilets of 30 homes. Methods: Bacteria were sampled with an MAS100 impactor in three spaces in the subject homes between April 2014 and February 2015. Bacteria were grown on TSA plates for 48 hours at $35^{\circ}C$. The bacterial strains were isolated and amplified by polymerase chain reaction. Results: The most culturable bacteria were found in toilets ($624.0CFU/m^3$, GM: $417.3CFU/m^3$), followed by in the kitchen ($503.8CFU/m^3$, GM: $324.9CFU/m^3$). The dominant genera identified were: Staphylococcus sp.(19%), Micrococcus sp.(16%), and Bacillus sp.(11%) in the indoor air and Bacillus sp. (30%) in the outdoor air. Gram-positive bacteria comprised more than half of all colonies. Conclusion: In this study, culturable bacteria concentrations were higher than those reported in other spaces. Therefore, it is important to control relative humidity and remove moisture to prevent bacteria from multiplying. Additionally, the dominant species in indoor air were Staphylococcus sp. and Micrococcus sp. These are found on the human skin, mucous membranes, and hair, so human activity can affect bacterial distribution. Therefore, cleaning and controlling moisture are important for reducing indoor bacterial concentrations.
부유세균은 주택내 주요 공간인 거실, 주방, 화장실과 실외에서 실내공기질 공정시험기준에 따라 충돌법을 이용하여 MAS100 (Merck, Germany)으로 채취하였다. 외부 공기를 차단하기 위해 창문을 닫고 바닥에서 1.
성능/효과
계절변화에 따른 부유세균 농도는 모든 주거공간에서 봄과 여름에 농도가 높았으며, 여름에는 화장실의 습도가 69% 이상이었으며, 부유세균 기하평균 농도는 588.9 CFU/m3로 나타났다.
01). 그러므로 실외보다 실내의 부유세균 농도가 높은 것을 알 수 있었으며, 특히 화장실의 부유세균 농도가 높았다. 또한, 거실과 화장실은 통계적으로 유의하게 농도 차이가 났다.
3배로 측정되었으며, 사후분석 결과에서도 화장실과 거실의 부유세균 농도는 유의한 차이를 보이고 있었다. 또한 실내공기질 관리법의 부유세균 유지기준800 CFU/m3를 초과한 비율도 화장실이 27%로 다른 공간보다 높은 것으로 나타났다. 이러한 결과는 화장실의 높은 습기로 인한 것으로 판단되어지며, 실생활에서 환풍기 사용 등으로 습기제거, 주기적인 수분 제거 등으로 관리해야할 것으로 보인다.
3 CFU/m3으로 측정되었다. 또한 외기의 기하평균 농도는 66.8 CFU/m3으로 측정되었으며, 사후분석을 실시한 결과, 주거공간의 부유세균 농도는 외기와 유의한 차이를 나타내었다(p<0.01). 그러므로 실외보다 실내의 부유세균 농도가 높은 것을 알 수 있었으며, 특히 화장실의 부유세균 농도가 높았다.
Table 5는 계절에 따른 부유세균 농도와 실내공기의 오염여부를 확인하기 위한 실내/외 농도비 결과이다. 모든 주거공간에서 봄과 여름에 농도가 높았으며 사후분석을 실시한 결과를 살펴보면, 대부분 다른 계절과 겨울의 두 그룹으로 구분되고 통계적으로 유의한 차이를 나타내었다. 특히 여름에 화장실의 습도는 평균 69% 이상으로 증가하고 부유세균 기하평균 농도는 588.
본 연구결과를 통하여 습도가 높고 수분이 많은 화장실에서 부유세균이 높게 측정되어 부유세균 농도는 습도의 영향을 받음을 알 수 있다. 다중이용시설에서 측정한 부유세균과 습도의 회귀분석 결과를 살펴보면, 습도가 1% 오를 때마다 부유세균 농도가6.
본 연구에서는 그람양성균은 Micrococcus 속, Staphylococcus 속, Bacillus 속이 우점종으로 검출되었다. 그람양성균이 실내에 주로 검출된다는 연구 결과는 많이 이루어지고 있다.
부유세균 종을 동정한 결과, 그람양성균이 50% 이상을 차지하여, 그람음성균보다 저항성과 생존력이 강하여 검출율이 높게 나타났다. 우점종은 Staphylococcus 속, Micrococcus 속으로 주로 사람의 피부와 관련이 있는 종이 검출되었다.
실내/외 농도비를 살펴보면, 계절과 주거공간에 상관없이 농도비가 1이상으로 측정되었으며, 여름철에 화장실의 실내/외 농도비는 9.62로 가장 높게 측정되어 실내오염도가 높음을 알 수 있다. 실내의 부유세균이 실외보다 농도가 높다는 연구결과는 많이 보고되어지고 있으며20,21), 폴란드의 주택 실내 부유세균 기하평균 농도는 1021 CFU/m3로 실외 농도인 671 CFU/m3와 비교하여 높은 농도를 나타내었다.
5 CFU/m3으로 측정되었다. 아파트에서도 화장실의 부유세균 농도가 높았으며, 사후분석 결과, 거실과 화장실의 농도 차이가 유의하게 나타났다. 이러한 결과는 습하고 공간이 구분되는 공간인 화장실과 건조하고 환기가 용이한 거실의 공간 특성에 따른 것으로 판단되어진다.
아파트와 단독/다세대주택의 부유세균 농도를 비교해보면, 주거공간에 관계없이 단독/다세대주택의 부유세균 농도가 높았다. 2011년도에 국립환경과학원의 연구결과에서 아파트의 부유세균 농도는 1301.
아파트와 단독주택, 다세대주택의 주거공간별 부유세균 농도도 역시 주거형태와 상관없이 화장실 농도가 거실, 주방과 비교하여 약 1.1~1.6배 높은 것으로 나타났다. 또한 추가적으로 아파트보다 단독·다세대주택의 부유세균 농도가 모든 공간에서 높게 측정되었다.
아파트의 평균 부유세균 농도는 Table 3과 같으며, 거실의 기하평균 농도는 230.8 CFU/m3, 주방은 255.1 CFU/m3, 화장실은 367.5 CFU/m3으로 측정되었다. 아파트에서도 화장실의 부유세균 농도가 높았으며, 사후분석 결과, 거실과 화장실의 농도 차이가 유의하게 나타났다.
주거공간에 따른 부유세균 농도를 살펴보면 화장실의 기하평균 농도는 거실보다 1.5배, 주방보다 1.3배로 측정되었으며, 사후분석 결과에서도 화장실과 거실의 부유세균 농도는 유의한 차이를 보이고 있었다. 또한 실내공기질 관리법의 부유세균 유지기준800 CFU/m3를 초과한 비율도 화장실이 27%로 다른 공간보다 높은 것으로 나타났다.
모든 주거공간에서 봄과 여름에 농도가 높았으며 사후분석을 실시한 결과를 살펴보면, 대부분 다른 계절과 겨울의 두 그룹으로 구분되고 통계적으로 유의한 차이를 나타내었다. 특히 여름에 화장실의 습도는 평균 69% 이상으로 증가하고 부유세균 기하평균 농도는 588.9 CFU/m3로 높게 측정되었다.
후속연구
그러므로 본 연구에서는 주택내 주거공간의 특성에 따라 거실, 주방과 화장실을 구분하여 부유세균 농도를 알아보고자 하였다. 또한 실내·외 세균 종 분포를 조사하여 부유세균 관리의 기초자료로 활용하고자 한다.
질의응답
핵심어
질문
논문에서 추출한 답변
바이오에어로졸의 구성 성분은 무엇인가?
하며, 세균, 곰팡이 포자, 바이러스 등의 살아있거나 죽은 생물체로부터 기인한 입자상물질, 독소로 구성되어 있다. 이러한 바이오에어로졸은 수분, 토양, 먼지 등에 흡착되어 이동하면서 실내공기질에 영향을 준다.
실내공기가 미생물이 번식할 수 있는 좋은 조건인 이유는 무엇인가?
이러한 바이오에어로졸은 수분, 토양, 먼지 등에 흡착되어 이동하면서 실내공기질에 영향을 준다.1,2) 특히, 실내공기는 사람이 생활하기 적합한 온도와 산소농도가 유지되고 있기 때문에 미생물이 번식할 수 있는 좋은 조건이다.3) 또한, 인플루엔자 등 급성 호흡기질환을 포함한 감염성질환의 매개체 역할을 한다.
부유세균과 같은 주택 내 미생물 군집에 영향을 주는 요인에는 무엇이 있는가?
다양한 바이오에어로졸 중에서 부유세균은 천식 등의 알레르기성 질환과 연관성이 있으며, 재채기, 대화 등 거주자의 활동은 실내 표면의 오염물질을 부유시켜 부유세균 농도에 영향을 준다.9-12) 또한, 실내 온도, 습도, 주택의 크기, 환기 횟수, 거주자의 수 등은 주택 내 미생물 군집에 영향을 주는 요인들이다.
참고문헌 (37)
Balasubramanian R, Nainar P, Rajasekar A. Airborne bacteria, fungi, and endotoxin levels in residential microenvironments : a case study. Aerobiologia. 2012; 28(3): 375-390.
Moon KW, Huh EH, Jeong HC. Seasonal evaluation of bioaerosols from indoor air of residential apartments within the metropolitan area in South Korea. Environ Monit Assess. 2014; 186(4): 2111-2120.
Kim MK. Determinations of total culturable bacteria in the university spaces. Korea Society of Environmental Administration. 2014; 20(2): 43-48.
Li Y, Leung M, Tang JW, Yang X, Chao CYH, Lin JZ, et al. Role of ventilation in airborne transmission of infectious agents in the built environment - a multidisciplinary systematic review. Indoor Air. 2007; 17(1): 2-18.
Seitz TA. NIOSH indoor air quality investigations : Proceedings of the Indoor Air Quality International Symposium, Cincinnati, OH, NIOSH, 1989.
Malgorzata GS, Gorny RL. Bacterial and fungal aerosols in air-conditioned office buildings in warsaw, poland-the winter season. Int J Occup Saf Ergon. 2010; 16(4): 465-476.
Pastuszka JS, Kyaw Tha Paw U, Lis DO, Wlaslo A, Ulfig K. Bacterial and fungal aerosol in indoor environment in Upper Silesia, Poland. Atmos Environ. 2000; 34(22): 3833-384.
Kim YS, Roh YM, Lee CM, Kim KY, Kim JC, Jeon HJ, et al. A study of excess ratio for guideline of indoor air pollutants in classroom of kindergartens. J Korean Soc Indoor Environ. 2007; 4(1): 14-22.
Ferro AR, Kopperud RJ, Hildemann LM. Source strengths for indoor human activities that resuspend particulate matter. Environ Sci Technol. 2004; 38: 1759-1764.
Koistinen KJ, Edwards RD, Mathys P, Ruuskanen J, Kunzli N, et al. Sources of fine particulate matter in personal exposures and residential indoor, residential outdoor and workplace microenvironments in the Helsinki phase of the EXPOLIS study. Scand J Work Env Hea. 2004; 30: 36-46.
Koperrud RJ, Ferro AR, Hildemann LM. Outdoor versus indoor contributions to indoor particulate matter (PM) determined by mass balance methods. J Air Waste Manage Assoc. 2004; 54: 1188-1196.
ACGIH. Bioaerosols Assessment and Control ACGIH, 1999
Moschandreas DJ, Pagilla KR, Storino LV. Time and space unifomity of indoor bacteria concentrations in Chicago area residences. Aerosol Sci Tech. 2003; 37(11): 899-906.
Moon HJ, An KA, Choi MS. The status and causes of indoor airborne microorganisms activities in residential buildings. J Korean Soc Living Environ Sys. 2012; 19(6): 669-675.
Sibel M, Munevver A, Abbas, YR, Gulen, G. Bacterial and fungi levels in various indoor and outdoor environments in Ankara, Turkey. Soil Air Water. 2009; 37(6). 487-493.
Lee SH, Jeong SK, Lee KS, Min KW, Kim HS, Kim DS, et al. A study on characteristics of indoor air pollutants using regression analysis in public facillities. J Korean Soc for Environ Anal. 2013; 16(2): 123-132.
Lee JH, Jo WK. Characteristics of indoor and outdoor bioaerosols at Korean high-rise apartment buidlings. Environ Res. 2006; 101(1): 11-17.
Kim KY, Cho MS, Kim YS, Lee CM. Study on outdoor distribution characteristics of airborne bacteria in Korea, Korean Soc Atmos Environ. 2009; 5: 115-117.
Lee JH, Jo WK. Characteristics of indoor and outdoor bioaerosols at Korean high-rise apartment buildings. Environ Res. 2006; 101(1): 11-17.
Scheff PA, Paulius VK, Curtis L, Conroy LM. Indoor air quality in a middle school, Part II: development of emission factors for particulate matter and bioaerosols. Appl Occup Environ Hyg. 2000; 15(11): 835-842.
Lou X, Fang Z, Si G. Assessment of culturable airborne bacteria in university campus in Hangzhou. Southeast of China. Afr J Microbio Res. 2012; 6(3): 665-673.
Kim NY, Kim YR, Kim MK, Cho DW, Kim JS. Isolation and charcterization of airborne bacteria and fungi in indoor environment of elementary schools. Kor J Microbio. 2007; 43(3): 193-200.
Asan A, Sen B, S, Sarica. Airborne fungi in urban air of Edirne City (Turkey). Biologia. 2002; 57(1): 59-68.
Ekhaise FO, Ighosewe, OU, Ajakpovi OD. Hospital indoor airborne microflora in private and mary card. Infect Control Hosp Epidemiol. 2008; 22: 493-498.
Robertson CE, Baumgartner LK, Harris JK, Peterson KL, Stevenss MJ, Frank DN, et al. Cultureindependent analysis of aerosol microbiology in a metropolitan subway system. Appl environ microbiol. 2013; 79(11): 3485-3493.
Mandal J, Brandl H. Bioaerosols in indoor environment - A review with special reference to residential and occupational locations. Open Environ Biol Monit J. 2011; 4: 83-96.
Jeon BH, Hwang IY. Concentrations of total culturable microorganisms and its identification in public facilities, J Korea Acad Industr Coop Soc. 2015; 16(1): 868-876.
Kim JB, Kim JC. Antibioti resistance of food-borne pathogens isolated an indoor environment of a lunchroom in child center. Korean J Environ Health. 2012; 38(5): 415-423.
Bonetta S, Bonetta S, Mosso S, Sampo S, Carraro E. Assessment of microbiological indoor air quality in an Italian office building equipped with an HVAC system. Environ Monit Assess. 2010; 161(1): 473-483.
David W, Marcus, HY, Leung, Lee PKH. Indoor air bacteria communities in Hong Kong households assemble independently of occupant skin microbiomes. Environ Microbiol. 2015; 18(6): 1754-1763.
Aydogdu H, Asan A, Otkun MT. Indoor and outdoor airborne bacteria in child day-care centers in Edirine City(Turkey), seasonal distribution and influence of meteorological factors. Environ Monit Assess. 2010; 164(1): 53-66.
Dutkiewicz J, Krysinska-Traczyk E, Skorska C, Cholewa G, Sitkowska J. Exposure to airborne microorganisms and endotoxin in a potato processing plant. Ann Agri Environ Med. 2002; 9(2): 225-235.
Leila S, Mohammad R, Mohammad-Zadeh M, Saadat M. Comparison of CHROMagar acinetobacter and conventional methods for isolation Acinetobacter baumanni from tracheal aspirates patients with ventilator-associated pneumonia(VAP). Annals of Biol Res. 2013; 4: 46-52.
Sohn JR, Kim JM, Oh HJ, Nam IS, Yang JH, Lee DH, et al. Assement of particles and bioaerosol concentrations at daycard centers in Seoul. J Odor Indoor environ. 13(1), 40-48.
Mondogin EF, Shapir N, Daugherty SC, DeBoy RT, Emerson JB, Shvartzbeyn, A, et al. Secrets of soil survival revealed by the genome sequence of Arthrobacter aurescens TC1, PLoS genet. 2006; 2(12): 2094-2106.
Fang Z, Ouyang Z, Zheng H, Wang X, Hu L. Culturable airborne bacteria in outdoor Environments in Beijing. China. Microb Ecol. 2007; 54(3): 487-496.
※ AI-Helper는 부적절한 답변을 할 수 있습니다.