최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기한국정밀공학회지 = Journal of the Korean Society for Precision Engineering, v.34 no.6, 2017년, pp.411 - 415
이길재 (한국동서발전 기술정보처) , 김재훈 (충남대학교 기계공학부)
This paper aims to verify the reliability of the creep-life assessment regarding the STS304H-Type tube for which the hardness method of H. Tanaka is used. For this purpose, the creep-rupture test and the hardness test were conducted with a new tube and used tubes that were exposed to 96,000 hr under...
Doosan Heavy Industries, “Study on the Creep Strengthening Mechanism and Data Base Established to Predict Mechanical Properties in Heat Resistant Steels,” Korea Atomic Research Institute, p. 13, 2002.
Tanaka, H, Murata, M, Abe, F, Irie, H. Microstructural evolution and change in hardness in type 304H stainless steel during long-term creep. Materials science & engineering. properties, microstructure and processing. A, Structural materials, vol.319, 788-791.
ASME, “Boiler & Pressure Vessel Code, Section II Part A,” https://www.asme.org/shop/standards (Accessed 22 MAY 2017)
SHINYA, Norio, KYONO, Junro, TANAKA, Hideo, MURATA, Masaharu, YOKOI, Shin. Creep Rupture Properties and Creep Fracture Mechanism Maps for Type 304 Stainless Steel. 鐵と鋼 = Journal of the Iron and Steel Institute of Japan = Tetsu to hagane, vol.69, no.14, 1668-1675.
TANAKA, Hideo, MURATA, Masaharu, KAISE, Masatsugu, SHINYA, Norio. Creep-induced Grain Boundary Damage and Creep Properties of SUS 304. 鐵と鋼 = Journal of the Iron and Steel Institute of Japan = Tetsu to hagane, vol.74, no.10, 2009-2016.
ASTM International, “Standard Test Methods for Tension Testing of Metallic Materials,” https://www.astm.org/Standards/E8.htm (Accessed 22 MAY 2017)
National Research Institute for Metals, “National Research Institute for Metals Creep Data Sheet,” http://smds.nims.go.jp/index_en.html (Accessed 22 MAY 2017)
EPRI Technical, “Remaining Life Assessment of Austenitic Stainless Steel Superheater and Reheater Tubes,” https://www.epri.com/#/pages/product/1004517/ (Accessed 22 MAY 2017)