NTIS 바로가기한국지반환경공학회논문집 = Journal of the Korean Geoenvironmental Society, v.18 no.10, 2017년, pp.23 - 34
이동수 (School of Civil, Environmental and Architectural Engineering, Korea University) , 홍영호 (School of Civil, Environmental and Architectural Engineering, Korea University) , 홍원택 (School of Civil, Environmental and Architectural Engineering, Korea University) , 채광석 (Infra & Offshore Research Team, GS E&C) , 이종섭 (School of Civil, Environmental and Architectural Engineering, Korea University)
As the electrical property of fully saturated soils is dependent on the pore water, it has been commonly used for the detection of the contamination into the ground. The objective of this study is to investigate the electrical characteristics according to the salinity and the lead concentration in f...
핵심어 | 질문 | 논문에서 추출한 답변 |
---|---|---|
지반오염조사의 대표적인 방법은? | 일반적으로 지반오염조사는 흙이나 지하수를 샘플링하여 분석하는 방법이 대표적이지만, 운반 도중 샘플이 오염될 가능성이 존재하고 많은 비용과 시간이 필요하다는 문제가 있으며(Shang et al., 2004) 정확한 오염위치나 유출량 또한 산정이 어렵다는 단점이 있다. | |
육상 매립시설의 특징은? | 그러나 국내 여건상 신규 매립부지 확보는 어려운 실정이며, 이에 따른 대안인 폐기물 해상 처분장의 개발이 화두로 떠오르고 있다. 육상 매립시설에서 침출수는 매립시설 자체의 안정성에도 영향을 주며, 외부 환경에의 유해성이 존재하기 때문에 다수의 연구가 수행되어 왔다(Lee & Jones-Lee, 1996). 일반적으로 최상의 조건에서 설계된 이 중 라이너 매립시설의 경우도 1차 라이너를 통해 206L/hectare/day의 침출수가 발생할 수 있다(Bonaparte& Gross, 1990). | |
현장에서 라이너 매립시설의 장기간 모니터링을 수행해야 하는 이유는? | 육상 매립시설에서 침출수는 매립시설 자체의 안정성에도 영향을 주며, 외부 환경에의 유해성이 존재하기 때문에 다수의 연구가 수행되어 왔다(Lee & Jones-Lee, 1996). 일반적으로 최상의 조건에서 설계된 이 중 라이너 매립시설의 경우도 1차 라이너를 통해 206L/hectare/day의 침출수가 발생할 수 있다(Bonaparte& Gross, 1990). 이와 같은 이유로 침출수는 매립지에서 지속적인 문제로 작용하며, 이를 해결하기 위해서는 현장에서 장기간 모니터링을 수행해야 한다(Clément et al. |
Abu-Hassanein, Z. S., Benson, C. H. and Blotz, L. R. (1996), Electrical resistivity of compacted clays, Journal of Geotechnical Engineering, Vol. 122, No. 5, pp. 397-406.
Archie, G. E. (1942), The electrical resistivity log as an aid in determining some reservoir characteristics, Transactions of the AIME, Vol. 146, No. 1, pp. 54-62.
Benson, C. H. and Bosscher, P. (1999), Time-domain reflectometry in geotechnics: A review, nondestructive and automated testing for soil and rock properties, STP 1350, ASTM, W. Marr and C. Fairhurst, Eds., pp. 113-136.
Bonaparte, R. and Gross, B. A. (1990), Field behavior of double-liner systems, Waste containment systems: Construction, regulation, and performance, ASCE Geotechnical Special Publication No. 26, pp. 52-83.
Clement, R., Descloitres, M., Gunther, T., Oxarango, L., Morra, C., Laurent, J. P. and Gourc, J. P. (2010), Improvement of electrical resistivity tomography for leachate injection monitoring, Waste Management, Vol. 30, No. 3, pp. 452-464.
Isaac Eneji Evinemi., Adekunle Abraham Adepelumi. and Olasupo Adebayo. (2016), Canal structure subsidence investigation using ground penetrating radar and geotechnical techniques, International Journal of Geo-Engineering, Vol. 7, No. 9, DOI 10.1186/s40703-016-0023-x.
Fellner-Feldegg, H. (1969), Measurement of dielectrics in the time domain, The Journal of Physical Chemistry, Vol. 73, No. 3, pp. 616-623.
Fujiyasu, Y., Pierce, C. E., Fan, L. and Wong, C. P. (2004), High dielectric insulation coating for time domain reflectometry soil moisture sensor, Water resources research, Vol. 40, W04602, doi:10.1029/2003WR002460.
Giese, K. and Tiemann, R. (1975), Determination of the complex permittivity from thin-sample time domain reflectometry improved analysis of the step response waveform, Advances in Molecular Relaxation Processes, Vol. 7, No. 1, pp. 45-59.
Gondouin, M., Tixier, M. P. and Simard, G. L. (1957), An experimental study on the influence of the chemical composition of electrolytes on the SP curve, Petroleum Transactions, American Institute of Mining Engineers, Vol. 210, pp. 58-72.
Hong, W. T., Jung, Y. S., Lee, J. S. and Byun, Y. H. (2015), Development and application of TDR penetrometer for evaluation of soil water content of subsoil, Journal of the Korean Geotechnical Society, Vol. 31, No. 2, pp. 39-46 (in Korean).
Jones, S. B., Wraith, J. M. and Or, D. (2002), Time domain reflectometry measurement principles and applications, Hydrological processes, Vol. 16, No. 1, pp. 141-153.
Jung, S. H., Yoon, H. K. and Lee, J. S. (2011), Temperaturecompensated resistivity probe - development and application, Journal of the Korean Geo-Environmental Society, Vol. 12, No. 1, pp. 51-60 (in Korean).
Kaya, A. and Fang, H. Y. (1997), Identification of contaminated soils by dielectric constant and electrical conductivity, Journal of Environmental Engineering, Vol. 123, No. 2, pp. 169-177.
Kim, D. J., Baek, D. S. and Park, M. S. (1999), Predicting migration of a heavy metal in a sandy soil using time domain reflectometry, Journal of the Korean Society of Soil and Groundwater Environment, Vol. 4, No. 1, pp. 109-118 (in Korean).
Kim, J. H., Yoon, H. K., Jung, S. H. and Lee, J. S. (2009), Development and verification of 4-electrode resistivity probe, Journal of the Korean Society of Civil Engineers, Vol. 29, No. 3, pp. 127-136 (in Korean).
Klein, K. and Santamarina, J. C. (1997), Methods for broadband dielectric permittivity measurements (soil-water mixtures, 5 Hz to 1.3 GHz), Geotechnical Testing Journal, GTJODJ, Vol. 20, No. 2, June 1997, pp. 168-178.
Lee, G. F. and Jones-Lee, A. (1996), Detection of the failure of landfill liner systems, Report of G. Fred Lee & Associates, El Macero, CA, 13p.
Noborio, K. (2001), Measurement of soil water content and electrical conductivity by time domain reflectometry: a review, Computers and Electronics in Agriculture, Vol. 31, No. 3, pp. 213-237.
O'Connor, K. M. and Dowding, C. H. (1999), GeoMeasurements by pulsing TDR cables and probes, CRC Press, 402p.
Oh, M. H., Park, J. B., Kim, Y. J., Hong, S. W. and Lee, Y. H. (2001), Development of contaminant leakage detection system using electrical resistance measurement: I. variation of electrical properties of subsurface due to contaminants, Journal of the Korean Geotechnical Society, Vol. 17, No. 6, pp. 215-224 (in Korean).
Park, J. B., Bang, S. Y. and Oh, M. H. (2003), Complex dielectric constant of unsaturated sand contaminated by heavy metals, Proceedings of 2003 Spring Conference on the Korean Society of Environmental Engineers, Deajeon, pp. 1420-1427 (in Korean).
Salako, A. O. and Adepelumi, A. A. (2016), Evaluation of hydraulic conductivity of subsoil using electrical resistivity and ground penetrating radar data: example from Southwestern Nigeria, International Journal of Geo-Engineering, Vol. 7, No. 5, DOI 10.1186/s40703-016-0018-7.
Santamarina, J. C., Klein, K. A. and Fam, M. A. (2001), Soils and waves-particulate materials behavior, Characterization and Process Monitoring, John Wiley and Sons, NY, 448p.
Sawyer, C. N., McCarth, P. L. and Parkin, G. F. (1994), Chemistry for environmental engineering, 4th Ed McGRAW-Hill, 768p.
Shang, J. Q., Ding, W., Rowe, R. K. and Josic, L. (2004), Detecting heavy metal contamination in soil using complex permittivity and artificial neural networks, Canadian Geotechnical Journal, Vol. 41, No. 6, pp. 1054-1067.
Smith, S. S. and Arulanandan, K. (1981), Relationship of electrical dispersion to soil properties, Journal of Geotechnical and Geoenvironmental Engineering, ASCE Vol. 107, No. 5, pp. 591-604.
Topp, G. C., Davis, J. C. and Annan, A. P. (1980), Electromanetic determination of soil water content : Measurements in coaxial transmission lines, Water Resources Research, Vol. 16, No. 3, pp. 574-582.
Thitimakorn, Thanop., Kampananon, Natamon., Jongjaiwanichkit, Napassapong. and Kupongsak, Sasikan. (2016), Subsurface void detection under the road surface using ground penetrating radar (GPR), a case study in the Bangkok metropolitan area, Thailand, International Journal of Geo-Engineering, Vol. 7, No. 2, DOI 10.1186/s40703-016-0017-8.