이강휘 (Dept. of Biomedical Engineering, KonKuk University) , 이성수 (Dept. of Biomedical Engineering, KonKuk University) , 김상민 (Dept. of Biomedical Engineering, KonKuk University) , 이혁재 (Dept. of Biomedical Engineering, KonKuk University) , 민경진 (Dept. of Biomedical Engineering, KonKuk University) , 강현규 (Dept. of Biomedical Engineering, KonKuk University) , 이주현 (Dept. of Clothing and Textiles, Yonsei University) , 곽휘권 (Hanwha Systems Co.,Ltd) , 고윤수 (Hanwha Systems Co.,Ltd) , 이정환 (Dept. of Biomedical Engineering, KonKuk University)
Recent advances in ICT technology have transformed many of our daily lives and attracted a lot of attention to personal health. Heart beat measurement that reflects cardiac activities has been used in various fields such as exercise evaluation and psychological state evaluation for a long time, but ...
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
핵심어 | 질문 | 논문에서 추출한 답변 |
---|---|---|
심전도는 어떻게 얻을 수 있는가? | 심전도는 탈분극과 재분극 과정을 거치면서 각각의 시간에 심장의 전기적 활동을 해석하여 얻을 수 있으며 심장 박동 수, 심장의 크기와 위치, 심장의 손상 여부 등의 생체 정보를 포함하고 있기 때문에 임상에서 많이 사용되고 있는 생체 신호이다. | |
심장의 전기활동을 정확하게 측정하기 위해서 전극의 위치를 어떻게 배치해야 하는가? | 이에 본 연구에서는 체표면에서 표준 심전도 전극의 구성을 따르지 않은 경우의 측정신호에 대하여, 측정전극 거리 변화와 위치에 따른 측정신호의 변화실험을 진행하였으며, 심장의 전기 쌍극자 모델에 근거하여, 임상표준보다 짧은 거리의 전극 구성으로 측정된 다수의 표면전위를 합성하여 임상 심전도와의 유사성을 확인할 수 있었다.심장의 전기활동을 정확하게 측정하기 위해서는 전극간의 거리가 가능한 멀리 배치해야 한다는 점이다. 임상 사지리드 유도법은 인체에서 가장 멀리 떨어진 왼팔과 오른팔의 손목 부위에 전극을 위치시키는 것은 바로 이런 이유에서이다. | |
병원에서 웨어러블 시계를 임상적인 심박측정기기로 사용하지 않는 이유는 무엇인가? | 그러나 아직도 병원에서 임상적으로 활용방안을 찾아가지 못하고 있으며, 단순한 운동 보조장치로 인식되고 있다. 이런 이유에는 다양한 원인이 있을 것으로 사료되나, 가장 큰 이유는 임상적으로 심장의 전기적 활동을 측정하는 심전도(Electrocardiography)와의 연관성(correlation)이 다르고, 임상의들이 해석하는 심전도의 기전에 대한 의미가 서로 다르기 때문일 것이다. 특히, 심장의 전기 활동을 기록한 심전도의 경우, 심장의 해부학적 근육의 움직임에 의한 생체전기 현상의 기전이 명확하여 유관 질환과의 연계성이 학문적으로 밝혀져 있으나[4], 시장에서 구입 가능한 다양한 웨어러블 형태의 심박 측정 장치들은 측정하는 부위, 환경 등 다양한 환경변수들에 의하여 측정된 파형의 유의미를 정확히 임상에서 질환으로 연결할 수 없기 때문에, 단순한 심장의 활동, 즉 심박만을 측정하는 목적으로 활용될 수밖에 없다[5]. |
E. Fung et al., "Electrocardiographic patch devices and contemporary wireless cardiac monitoring", Frontiers in Physiology, vol. 6, May 2015.
J. A. Walsh, E. J. Topol, and S. R. Steinhubl, "Novel Wireless Devices for Cardiac Monitoring", Circulation, vol. 130, no. 7, pp. 573-581, Aug. 2014.
A. M. Chan, N. Selvaraj, N. Ferdosi, and R. Narasimhan, "Wireless patch sensor for remote monitoring of heart rate, respiration, activity, and falls", Engineering in Medicine and Biology Society (EMBC), 2013 35th Annual International Conference of the IEEE, pp. 6115-6118, 2013.
S. Meek and F. Morris, "ABC of clinical electrocardiography: Introduction. I-leads, rate, rhythm, and cardiac axis", British Medical Journal, vol. 324, no. 7334, pp. 415-418, 2002.
M. Altini et al., "An ECG patch combining a customized ultra-low-power ECG SoC with Bluetooth low energy for long term ambulatory monitoring", Proceedings of the 2nd Conference on Wireless Health, p. 15, 2011.
L. Kang-Hwi et al., "Implementation of Wearable Heart Activity Monitoring System having Modified Bipolar Electrode and Correlation Analysis with Clinical Electrocardiograph (ECG)", The Transactions of The Korean Institute of Electrical Engineers, vol. 57, no. 6, p. 1102-1108, Jun. 2008.
E. Frank, "General Theory of Heart-Vector Projection", Circ Res, vol. 2, no. 3, pp. 258-270, May 1954.
D. B. Geselowitz, "Dipole theory in electrocardiography", The American Journal of Cardiology, vol. 14, no. 3, pp. 301-306, Sep. 1964.
W. H. Hayt, and J.A. Buck , Engineering Electromagnetics, 8th ed. New York: McGraw-Hill, 2012.
J. E. Madias, "Manual-based versus automation-based measurements of the amplitude of QRS complexes and T waves in patients with changing edematous states: clinical implications", Journal of Electrocardiology, vol. 41, no. 1, pp. 15-18, Jan. 2008.
J. E. Madias, "aVR, An Index of all ECG Limb Leads, with Clinical Utility for Monitoring of Patients with Edematous States, Including Heart Failure", Pacing and Clinical Electrophysiology, vol. 32, no. 12, pp. 1567-1576, Nov. 2009.