NTIS 바로가기한국농공학회논문집 = Journal of the Korean Society of Agricultural Engineers, v.60 no.4, 2018년, pp.105 - 111
임성윤 (National Institute of Agricultural Sciences, Rural Development Administration) , 김명환 (Geo Mechanics Technology Group) , 김유용 (National Institute of Agricultural Sciences, Rural Development Administration) , 유석철 (National Institute of Agricultural Sciences, Rural Development Administration) , 김석진 (National Institute of Agricultural Sciences, Rural Development Administration) , 임재삼 (National Institute of Agricultural Sciences, Rural Development Administration)
Institutional inertia anti-disaster standard was presented mainly on the upper surface, it is necessary to improve to the soil type standard and uplift the resistance standard greenhouse that are vulnerable to strong winds. In this study, we carried out a field test using the load control method in ...
핵심어 | 질문 | 논문에서 추출한 답변 |
---|---|---|
호우와 강풍이 하우스 구조에 영향을 줄 경우 피해가 더 큰 이유는? | 그렇지만 호우와 강풍이 함께 농업시설에 영향을 줄 경우에는 피해가 크게 발생한다. 호우에 의해 지반이 침수된 상태에서는 하우스구조를 지지하는 토양이 무른 상태가 되어 기초가 강풍에 쉽게 인발되거나 전도되어 피해가 발생하기 쉽다(RDA, 2007). | |
하우스 구조에 피해를 주는 기상요인은? | 이처럼 하우스 구조에 피해를 주는 기상요인은 강풍과 폭설 이다. 호우에 의한 피해는 하우스 구조에 영향을 주기보다는 시설내부에서 자라고 있는 작물에 크게 영향을 준다. | |
국내 단동 하우스의 일반적인 시공 방법은? | 국내 단동 하우스의 경우, 서까래 파이프를 지표면에서 30∼ 40cm 정도의 깊이로 지반에 삽입하여 시공하는 것이 일반적이다. 따라서 내재해형 단동플라스틱 필름 하우스는 서까래 파이프의 인발저항력이나 침하저항을 개선할 목적으로 서까래 파이프의 지중 매립 부분(40∼50cm)의 중간정도(25cm전 후)의 지점에 도리 파이프를 연결한 형태의 파이프 줄기초를 설치하도록 설계되어 있다. |
Japanese Society of Soil Mechanics and Foundation Engineering (JSSMFE), 1992. Uplift load testing method of piles (JSF 1821-1989), Japan.
Kim, M. K., S. W. Nam, J. E. Son, and N. K. Yun, 1994. Analyses of actual state and structural safety of regionally characterized greenhouse in Korean. Protected Horticulture and Plant Factory 3(2): 128-135 (in Korean).
Kim, M. K., and S. W. Nam, 1995. Experimental studies on the structural safety of pipe-houses. Protected Horticulture and Plant Factory 4(1): 17-24 (in Korean).
Kim, M. K., and S. W. Nam, W. M. Suh, Y. C. Yoon, S. G. Lee, and H. W. Lee, 2000. Agricultural facility engineering. 1st Ed. Hyangmoonsa, Seoul, Korea, 79-80.
Ministry for Food, Agriculture, Forestry and Fisheries (MIFAFF), Rural Development Administration (RDA), 2014. Designated notice of standards to endure disaster for horticultural and special facilities. eds. MIFAFF & RDA, Gwacheon and Suwon, Korea.
Ogawa, H., I. Tsuge, Y. Sato, S. Hoshiba, and S. Yamashita, 1990. Experimental analysis on strength of pipe-house with Ground anchoring (II). The Journal the Society of Agricultural Structures 20: 262-269.
Rural Development Administration (RDA), 2007. Symposium for reducing of meteorological disasters of agricultural facilities, 160-161, eds, RDA, Suwon, Korea.
RDA, NAAS, Department of agricultural engineering, 2007. Guide book for reduction of meteorological disaster of agricultural facilities (in Korean).
Yoon, Y. C., W. M. Suh, and J. H. Cho, 2001. The uplift capacity of plane and corrugated piles for pipe frame greenhouse. Protected Horticulture Plant Factory 10(3): 148-154 (in Korean).
Yun, S. W., M. K. Choi, S. Y. Lee, and Y. C. Yoon, 2015. Uplift capacity of meteorological disaster. Journal of Agriculture & Life Science 49(5): 303-310.