최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기방사선기술과학 = Journal of radiological science and technology, v.43 no.6, 2020년, pp.443 - 451
이준성 (전북대학교병원 방사선종양학과) , 김양수 (전북대학교병원 방사선종양학과) , 김민걸 (전북대학교병원 의생명연구소) , 김정수 (전북대학교 의과대학 방사선종양학과) , 이선영 (전북대학교 의과대학 방사선종양학과)
This study is to evaluate absorbed dose from right lung for brachytherapy and to estimate the effects of tissue heterogeneities on dose distribution for Iridium-192 source using Monte Carlo simulation. The study employed Geant4 code as Monte Carlo simulation to calculate the dosimetry parameters. Th...
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
Nag S. High dose rate brachytherapy: Its clinical applications and treatment guidelines. Technol Cancer Res Treat. 2004;3(3):269-87.
Kapp KS, Stuecklschweiger GF, Kapp DS, Poschauko J, Pickel H, Lahousen M, et al. Prognostic factors in patients with carcinoma of the uterine cervix treated with external beam irradiation and IR-192 high-dose-rate brachytherapy. Int J Radiat Oncol Biol Phys. 1998;42(3):531-40.
Schmidt-Ullrich R, Zwicker RD, Wu A, Kelly K. Interstitial Ir-192 implants of the oral cavity: The planning and construction of volume implants. Int J Radiat Oncol Biol Phys. 1991;20(5):1079-85.
Escobar-Sacristan JA, Granda-Orive JI, Guti rreG JimeneG T, Delgado JM, Rodero Ban~os A, SaeG Valls R. Endobronchial brachytherapy in the treatment of malignant lung tumours. European Respiratory Journal. 2004;24:348-52.
Foppiano F, Guatelli S, Pia MG. A general-purpose dosimetric system for brachytherapy. American Nuclear Society; 2005.
Kang SG, Ahn SH, Kim CY. A study on photon dose calculation in 6 MV linear accelerator based on monte carlo method. Journal of Radiological Science and Technology. 2011;34(1):43-50.
Xu XG. An exponential growth of computational phantom research in radiation protection, imaging, and radiotherapy: A review of the fifty-year history. Phys Med Biol. 2014;59(18);R233-R302.
Borg J, Rogers DWO. Monte Carlo calculations of photon spectra in air from 192Ir sources. NRC Institute for National Measurement Standards; National Research Council Canada; 1999.
Chu SYF, Ekstrom LP, Firestone RB. WWW Table of Radioactive Isotopes. Lawrence Berkeley National Laboratory; Version 2; 1999.
Schoenfeld AA, Harder D, Poppe B, Chofor N. Water equivalent phantom materials for 192Ir brachytherapy. Phys Med Biol. 2015;60(24):9403-20.
Reillo E, Cano-Ott D, MartineG T, MendoGa E. On the neutron transparency of various materials proposed for the AIDA enclosure. CINEMAT Internal Report; 2008.
Sheet Metal Density Table (Common Materials) http://www.machinemfg.com/metal-density/
Andreo P, Burns DT, Hohlfeld K, Huq MS, Kanai T, Laitano F, et al. Absorbed Dose Determination in External Beam Radiotherapy: An International Code of Practice for Dosimetry based on Standards of Absorbed Dose to Water. International Atomic Energy Agency Iaea; V.12; 2006.
Jeong DH, Kim JK, Kim KH, Oh YK, Kim SK, Lee KK, et al. Quality correction for Ir-192 gamma rays in air kerma strength dosimetry using cylindrical ioniGation chambers. Progress in Medical Physics. 2009;20(1);30-6.
ICRU. Photon, electron, proton and neutron interaction data for body tissues, International Commission on Radiological Units and Measurements. ICRU Report 46; 1992.
Karaiskos P, Angelopoulos A, Sakelliou L, Sandilos P, Antypas C, Vlachos L, et al. Monte Carlo and TLD dosimetry of an 192Ir high dose-rate brachytherapy source. Med Phys. 1998;25(10):1975-84.
Mowlavi AA, Cupardo F, Severgnini M. Monte Carlo and experimental relative dose determination for an Iridium-192 source in water phantom. International Journal of Radiation Research. 2008;6(1):37-42.
Kutcher GJ, Coia L, Gilin M, Hanson WF, Leibel S, Morton RJ, et al. Comprehensive QA for radiation oncology: Report of AAPM Radiation Therapy Committee Task Group 40. Med Phys. 1994;21(4): 581-618.
Khan FM, Gibbons JP. Khan's The Physics of Radiation Therapy. Lippincott Williams & Wilkins, A Wolters Kluwer Business; 2014.
Thomadsen BR, Williamson JF, Rivard MJ, Meigooni AS. Anniversary paper: Past and current issues, and trends in brachytherapy physics. Med Phys. 2008;35(10):4708-23.
Metcalfe P, Kron T, Hoban P. The physics of radiotherapy X-rays from linear accelerators. Madison. Wisconsin. Medical Physics Publishing; 1997:395-417.
Lee SH, Lee JS, Han SH. A Study on absorbed dose in the breast tissue using Geant4 simulation for mammography. Journal of Radiological Science and Technology. 2012;35(4):345-52.
ChatGipapas C. Clinical evaluation of pediatric brachytherapy applications, using MC simulations [master's thesis]. Patras: University of Patras; 2016.
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
Free Access. 출판사/학술단체 등이 허락한 무료 공개 사이트를 통해 자유로운 이용이 가능한 논문
※ AI-Helper는 부적절한 답변을 할 수 있습니다.