The price of the Brain phantom (Hoffman 3D brain phantom) used in nuclear medicine is quite expensive, it is difficult to be purchased by a medical institution or an educational institution. Therefore, the purpose of present research is to produce a low-price 3D brain phantom and evaluate its useful...
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
Sweet WH. The uses of nuclear disintegration in the diagnosis and treatment of brain tumor. New England Journal of Medicine. 1951;245(23):875-8.
Hounsfield GN. Computerized transverse axial scanning (tomography): Part 1. Description of system. British Journal of Radiology. 1973;46(552):1016-22.
Cho ZH, Chan JK, Eriksson L. Circular ring transverse axial positron camera for 3-dimensional reconstruction of radionuclides distribution. IEEE Transactions on Nuclear Science. 1976;23(1):613-22.
Hoffman EJ, Phelps ME, Mullani NA, Higgins CS, Ter-Pogossian MM. Design and performance characteristics of a whole-body positron transaxial tomograph. Journal of Nuclear Medicine. 1976;17(6):493-502.
Cho JH. Fusion images of molecular imaging era PET-MRI. Molecular and Cellular Biology News. 2005;17(3):43-51.
Park SO, Ahn SM. Gamma ray detection processing in PET/CT scanner. Journal of the Korean Society of Radiological Technology. 2006;29(3):125-32.
International Electrotechnical Commission. EC Standard 61675-1: Radionuclide Imaging Devices-Characteristics and Test Conditions. Part 1. Positron Emission Tomographs. International Electrotechnical Commission, Geneva, Switzerland; 1998.
Lee BI. Quality assurance and performance evaluation of PET/CT. Nuclear Medicine and Molecular Imaging. 2008;42(2):137-44.
Collins DL, Zijdenbos AP, Kollokian V, Sled JG, Kabani NJ, Holmes CJ, et al. Design and construction of a realistic digital brain phantom. IEEE Transactions on Medical Imaging. 1998;17(3):463-8.
Lim GC, Jung JH, Heo YS, Choi Y. Nuclear medical imaging system. The Institute of Electronics and Information Engineers. 2013;40(7):29-42.
Ham SM. Attenuation correction for human brain PET image using a CT template [Master Thesis]. Ewha Womans University; 2017.
Lee JR, Choi Y, Choe YS, Lee KH, Kim SE, Shin SA, et al. Performance measurements of positron emission tomography: An investigation using general electric Advance TM . The Korean Journal of Nuclear Medicine. 1996;30(4):548-59.
Teuho J, Johansson J, Linden J, Saunavaara V, Tolvanen T, Ters M. Quantitative bias in PET/MR from attenuation correction and reconstruction: A comparison with PET and PET/CT with an anatomical brain phantom and Hoffman brain phantom. IEEE Nuclear Science Symposium and Medical Imaging Conference; 2013.
Li HJ, Votaw JR. Optimization of PET activation studies based on the SNR measured in the 3-D Hoffman brain phantom. IEEE Transactions on Medical Imaging. 1998;17(4);596-605.
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
Free Access. 출판사/학술단체 등이 허락한 무료 공개 사이트를 통해 자유로운 이용이 가능한 논문
※ AI-Helper는 부적절한 답변을 할 수 있습니다.