NTIS 바로가기Nuclear engineering and technology : an international journal of the Korean Nuclear Society, v.52 no.2, 2020년, pp.296 - 307
Yan, Xiao-Xue (School of Electrical and Automation Engineering, Hefei University of Technology) , Xu, Ke-Jun (School of Electrical and Automation Engineering, Hefei University of Technology) , Xu, Wei (School of Electrical and Automation Engineering, Hefei University of Technology) , Yu, Xin-Long (School of Electrical and Automation Engineering, Hefei University of Technology) , Wu, Jian-Ping (School of Electrical and Automation Engineering, Hefei University of Technology)
Permanent magnet sodium flowmeter (PMSF) have been used to measure the sodium flow in fast breeder reactors. Due to the effects of irradiation, thermal cycling, time lapse, etc., the magnetic flux density of the PMSF will decrease after being used in the reactor for a period of time. Therefore, it m...
A.C. Raptis, G.A. Forster, A signal analysis method using cross-correlation of turbulence flow signals to determine calibration of permanent magnet sodium flowmeters, IEEE Trans. Nucl. Sci. 25 (1977) 278-281.
A. Endou, In service calibration method of electromagnetic flowmeter for LMFBR utilizing cross correlation of output voltage fluctuations, J. Nucl. Sci. Technol. 21 (1984) 501-514.
H. Araki, Electromagnetic flowmeter in-situ calibration by the flow fluctuation cross correlation method, Trans. Soc. Instrum. Control Eng. 22 (2009) 210-217.
R. Ramakrishna, P. Anup Kumar, et al., In-situ calibration of permanent magnet flowmeters in PFBR using noise analysis technique, Flow Meas. Instrum. 34 (2013) 76-82.
Y.Y. Liu, D.L. Chen, J.W. Yang, et al., Correlation sodium flow measurement system design based on labview, Atomic Energy Sci. Technol. 49 (2015) 1865-1869.
Z.-P. Shu, K.-J. Xu, The comparison of biased estimate and unbiased estimate on cross-correlation analysis, J. Electr. Electron. Educ. 39 (2017) 32-34.
L.-A. Xu, Cross-correlation Flow Measurement Technique, first ed., Tianjin University Press, Tianjin, July 1988.
W.-C. Cai, Q.-G. Ying, The New Flow Detection Instrument, first ed., Chemical Industry Press, Beijing, January, 2006.
L.A. Adamovskii, Vortex electromagnetic flow meters for liquid metal coolants, Meas. Tech. 50 (2007) 58-65.
A. Venugopal, A. Agrawal, S.V. Prabhu, A vortex cross-correlation flowmeter with enhanced turndown ratio, Rev. Sci. Instrum. 85 (2014), 06619.
C.H. Tang, B.B. Dong, B.Z. Ma, Argon Distribution System in Sodium Cooled Fast Reactor, 2011. Pub.No.CN2011/101174479B, Pub. Data: Sep.14.
K.-J. Xu, Y.-Z. Huang, Y.R. Lin, Q. Chen, Signal Analysis and Processing, second ed., Tsinghua University Press, Beijing, December, 2012.
Y.B. Ji, S.R. Qin, et al., Research on the boundary effect problem of finite interval signals, J. Vib. Shock 21 (2002) 108-111.
※ AI-Helper는 부적절한 답변을 할 수 있습니다.