NTIS 바로가기International journal of high-rise buildings, v.9 no.2, 2020년, pp.175 - 185
Sun, Xiaofeng (Department of Structural Engineering, Tongji University) , Li, Zheng (Department of Structural Engineering, Tongji University) , He, Minjuan (Department of Structural Engineering, Tongji University)
Currently, few studies have been conducted to comprehend the seismic reliability of post-tensioned (PT) CLT shear wall structures, due to the complexity of this kind of structural system as well as due to lack of a reliable structural model. In this paper, a set of 4-, 8-, 12-, and 16-storey benchma...
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
Akbas, T., Sause, R., Ricles, J. M., Ganey, R., Berman, J., Loftus, S., Daniel, J. D., Pei, S. L., van de Lindt, J., Blomgren, H. E. (2017). "Analytical and experimental lateral-load response of self-centering post-tensioned CLT walls." J. Struct. Eng., 143(6), 04017019.
Blomgren, H. E., Pei, S., Jin, Z., Powers, J., Dolan, J. D., van de Lindt, J. W. (2019). "Full-scale shake table testing of cross-laminated timber rocking shear walls with replaceablecomponents." J. Struct. Eng., 145(10), 04019115.
Buchanan, A., Iqbal, A., Palermo, A. G., Pampanin, S. (2007). "Improved seismic performance of LVL post-tensioned walls coupled with UFP devices." In: 8th Pacifc conf. On earthquake engineering. New Zealand Society for Earthquake Engineering and Nanyang Technological Univ., School of Civil and Environmental Engineering, Wellington, New Zealand, 1-9.
Ceccotti, A., Sandhaas, C., Okabe, M., Yasumura, M., Minowa, C., Kawai, N. (2013). "SOFIE project- 3D shaking table test on a seven-storey full-scale cross-laminated building." Earthq. Eng. Struct. Dyn., 42(13), 2003-2021.
Chen, Z., Popovski, M., Iqbal, A. (2020). "Structural performance of post-tensioned CLT shear walls with energy dissipaters." J. Struct. Eng., 146(4), 04020035.
Cornell, C. A., Jalayer, F., Hamburger, R. O., Foutch, D. A. (2002). "Probabilistic basis for 2000 SAC federal emergencymanagement agency steel moment frame guidelines." J. Struct. Eng., 128(4), 526-533.
Deng, P., Pei, S., van de Lindt, J., John, W., Omar Amini, M., Liu, H. (2019). "Lateral behavior of panelized CLT walls: A pushover analysis based on minimal resistance assumption." Eng, Struct., 191, 469-478.
Ganey, R., Berman, J., Akbas, T., Loftus, S., Daniel Dolan, J., Sause, R., Ricles, J., Pei, S. L., van de Lindt, J., Blomgren, H. E. (2017). "Experimental investigation of self-centering crosslaminated timber walls." J. Struct. Eng., 143(10), 04017135.
Gavric, I., Fragiacomo, M., Ceccotti, A. (2015). "Cyclic behavior of CLT wall systems: experimental tests and analytical prediction models." J. Struct. Eng., 141(11), 04015034.
He, M. J., Sun, X. F., Li, Z. (2018). "Bending and compressive properties of cross-laminated timber (CLT) panels made from Canadian hemlock." Constr. Build. Mater., 185, 175-183.
Hong, H. P., Yang, S. C. (2019). "Reliability and fragility assessment of the mid-and high-rise wood buildings subjected to bidirectional seismic excitation." Eng. Struct.,201, 109734.
Li, M., Lam, F., Foschi, R. O., Nakajima, S., Nakagawa, T. (2012). "Seismic performance of post-and-beam timber buildings II: reliability evaluations." J. Wood. Sci., 58(2), 135-143.
Mahsuli, M., Haukaas, T. (2013). "Computer program for multi-model reliability and optimization analysis." J. Comput. Civil. Eng., 27(1), 87-98.
GB 50068 (2018). Unified standard for reliability design of building structures. Ministry of Construction of the People's Republic of China. Beijing, China. (in Chinese).
Newcombe, M. P., Pampanin, S., Buchanan, A. H. (2010). "Design, fabrication and assembly of a two-storey post-tensioned timber building." In: Proc. World Conference on Timber Engineering, Trentino, Italy, 3092-3100.
Padgett, J. E., Nielson, B. G., DesRoches, R. (2008). "Selectionof optimal intensity measures in probabilistis seismic demand models of highway bridge portfolios." Earthq. Eng. Struct. Dyn., 37(5), 711-725.
Pai, S. G. S., Lam, F., Haukaas, T. (2017). "Force Transfer around openings in Cross-laminated timber shear walls." J. Struct. Eng., 143(4), 4016215.
Palermo, A., Pampanin, S., Buchanan, A. (2006). "Experimentalinvestigations on LVL seismic resistant wall and frame subassemblies." In: Proc. Of frst European conference on earthquake engineering and seismology, Geneva, Switzerland, No. 983.
Pei, S., van de Lindt, J. W., Barbosa, A. R., Berman, J. W., McDonnell, E., Daniel Dolan, J., et al. (2019). "Experimental seismic response of a resilient 2-story mass-timber building with post-tensioned rocking walls." J. Struct. Eng., 145(11), 04019120.
Porcu, M. C., Bosu, C., Gavric, I. (2018). "Non-linear dynamic analysis to assess the seismic performance of cross-laminated timber structures." J. Build. Eng., 19, 480-493.
Sarti, F., Palermo, A., Pampanin, S., Berman, J. (2017). "Deter-mination of the seismic performance factors for post-tensioned rocking timber wall systems: seismic performance factors for post-tensioned timber wall systems." Earthq. Eng. Struct. Dyn., 46, 181-200.
Sarti, F., Palermo, A., Pampanin, S. (2015). "Quasi-static cyclic testing of two-thirds scale un-bonded post-tensioned rocking dissipative timber walls." J. Struct. Eng., 142(4), E4015005.
Shahnewaz, M., Popovski, M., Tannert, T. (2019). "Resistanceof cross-laminated timber shear walls for platform-type construction." J. Struct. Eng., 145(12), 4019149.
Shu, Z., Li, S., Sun, X. F., He, M. J. (2019). "Performance-based seismic design of pendulum tuned mass damper system." J. Earthq. Eng., 23(2), 334-355.
Smith, T., Ludwig, F., Pampanin, S., Fragiacomo, M., Buchanan, A., Deam, B., Palermo, A. (2007). "Seismic response of hybrid-LVL coupled walls under quasi-static and pseudodynamic testing." In: Proc. Of New Zealand society for earthquake engineering conference, Palmerston North, New Zealand, Vol. 8.
Stellacci, S., Rato, V., Poletti, E., et al. (2018). "Multi-criteriaanalysis of rehabilitation techniques for traditional timber frame walls in Pombalino buildings (Lisbon)." J. Build. Eng., 16, 184-198.
Sun, X. F., He, M. J., Li, Z., Lam, F. (2019). "Seismic performance assessment of conventional CLT shear wall structures and post-tensioned CLT shear wall structures." Eng. Struct., 196, 109285.
Sun, X. F., He, M. J., Li, Z. (2020a). "Experimental and analytical lateral performance of post-tensioned CLT shear walls and conventional CLT shear walls." J. Struct. Eng., DOI: 10.1061/(ASCE)ST.1943-541X.0002638.
Sun, X. F., He, M. J., Li, Z., Lam, F. (2020b). "Seismic performance of energy-dissipating post-tensioned CLT shear wall structures I: Shear wall modeling and design procedure." Soil. Dyn. Earthq. Eng., 131, 106022.
Sun, X. F., He, M. J., Li, Z., Lam, F. (2020c). "Seismic performance of energy-dissipating post-tensioned CLT shear wall structures II: Dynamic analysis and dissipater comparison." Soil. Dyn. Earthq. Eng., 130, 105980.
van de Lindt, J. W., Walz, M. A. (2003). "Development and application of wood shear wall reliability model." J. Struct. Eng., 129(3), 405-413.
van de Lindt, J. W., John, W., Furley, J., Amini, M. O., Pei, S., Tamagnone, G., Barbosa, A. R., et al. (2019). "Experimentalseismic behavior of a two-story CLT platform building." Eng. Struct., 183, 408-422.
Wilson, A. W., Motter, C. J., Phillips, A. R., Dolan, J. D. (2019). "Modeling techniques for post-tensioned cross-laminated timber rocking walls." Eng. Struct., 195, 299-308.
Zhang, J., Huo, Y. L. (2009). "Evaluating effectiveness and optimum design of isolation devices for highway bridges using the fragility function method." Eng. Struct., 31(8), 1648-1660.
Zhang, X., Shahnewaz, M., Tannert, T. (2018). "Seismic reliability analysis of a timber steel hybrid system." Eng. Struct., 167: 629-638.