This paper is to establish a basis for a dose reduction strategy by confirming correlations with the factors that may affect the radiation dose based on the dose records in low-dose chest CT and abdominal non-contrast CT. In order to find out the causes of unnecessary exposure, the correlation betwe...
E. S. Amis Jr, P. F. Butler, K. E. Applegate, S. B. Birnbaum, L. F. Brateman, J. M. Hevezi, F. A. Mettler, R. L. Morin, M. J. Pentecost, G. G. Smith, K. J. Strauss, R. K. Zeman, "American College of Radiology white paper on radiation dose in medicine," Journal of the American College of Radiology, Vol. 4, No. 5, pp. 272-484, 2007. https://doi.org/10.1016/j.jacr.2007.03.002
M. S. Pearce, J. A. Salotti, M. P. Little, K. McHugh, C. Lee, K. P. Kim, N. L. Howe, C. M. Ronckers, P. Rajaraman, A. W. Craft, L. Parker, A. B. de Gonalez, "Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort study," The Lancet, Vol. 380, No. 9840, pp. 499-505, 2012. https://doi.org/10.1016/s0140-6736(12)60815-0
J. D. Mathews, A. V. Forsythe, Z. Brady, M. W. Butler, S. K. Goergen, G. B. Byrnes, G. G. Giles, A. B. Wallace, P. R. Anderson, T. A. Guiver, P. McGale, T. M. Cain, J. G. Dowty, A. D. Bickerstaffe, S. C. Darby, "Cancer risk in 680,000 people exposed to computed tomography scans in childhood or adolescence: data linkage study of 11 million Australians," BMJ, Vol. 346, pp. f2360, 2013. https://doi.org/10.1136/bmj.f2360
D. J. Brenner, E. J. Hall, "Computed tomography-an increasing source of radiation exposure," New England Journal of Medicine, Vol. 357, No. 22, pp. 2277-2284, 2007. http://dx.doi.org/10.1056/NEJMra072149
J. Boos, R. S. Lanzman, A. Meineke, P. Heusch, L. M. Sawicki, G. Antoch, P. Kropila, "Dose monitoring using the DICOM structured report: assessment of the relationship between cumulative radiation exposure and BMI in abdominal CT," Clinical Radiology, Vol. 70, No. 2, pp. 176-182, 2015. http://dx.doi.org/10.1016/j.crad.2014.11.002
A. Shah, P. Das, E. Subkovas, A. N. Buch, M. Rees, C. Bellamy, "Radiation dose during coronary angiogram: relation to body mass index," Heart, Lung and Circulation, Vol. 24, No. 1, pp. 21-25, 2015. http://dx.doi.org/10.1016/j.hlc.2014.05.018
W. Tan, S. Zhan, S. Yang, Y. Shuohui, R. Cheng, H. Zhan, "Reduction of radiation dose in the spiral CT scan of the lumbar spine by the combined use of body mass index (BMI) and automatic exposure control (AEC)," Journal of X-ray science and technology, Vol. 22, No. 6, pp. 697-706, 2014. http://dx.doi.org/10.3233/XST-140455
A. Hayes, E. Gearon, K. Backholer, A. Bauman, A. Peeters, "Age-specific changes in BMI and BMI distribution among Australian adults using cross-sectional surveys from 1980 to 2008," International Journal of Obesity, Vol. 39, No. 8, pp. 1209-1216, 2015. http://dx.doi.org/10.1038/ijo.2015.50
Y. Inoue, K. Nagahara, N. Hayakawa, H. Hanawa, H. Hata, "Monitoring dose-length product in computed tomography of the chest considering sex and body weight," Radiation Protection Dosimetry, Vol. 171, No. 3, pp. 375-381, 2016. https://doi.org/10.1093/rpd/ncv401
G. R. Iball, D. Tout, "Computed tomography automatic exposure control techniques in 18F-FDG oncology PET-CT scanning," Nuclear Medicine Communications, Vol. 35, No. 4, pp. 372-381, 2014. https://doi.org/10.1097/mnm.0000000000000064
U. Bhatti, K. Rani, M. Q. Memom, "Variation in lung volumes and capacities among young males in relation to height," Journal of Ayub Medical College Abbottabad, Vol. 26, No. 2, pp. 200-202, 2014.
J. W. Lambert, S. Kumar, J. S. Chen, Z. J. Wang, R. G. Gould, B. M. Yeh, "Investigating the CT localizer radiograph: acquisition parameters, patient centring and their combined influence on radiation dose," The British journal of radiology, Vol. 88, No. 1048, pp. 20140730, 2015. http://dx.doi.org/10.1259/bjr.20140730
K. Matsubara, K. Koshida, K. Ichikawa, M. Suzuki, T. Takata, T. Yamamoto, O. Matsui, "Misoperation of CT automatic tube current modulation systems with inappropriate patient centering: phantom studies," American Journal of Roentgenology, Vol. 192, No. 4, pp. 862-865, 2009. http://dx.doi.org/10.2214/AJR.08.1472
T. Toth, Z. Ge, M. P. Daly, "The influence of patient centering on CT dose and image noise," Medical Physics, Vol. 34, No. 7, pp. 3093-3101, 2007. https://doi.org/10.1118/1.2748113