최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기Nuclear engineering and technology : an international journal of the Korean Nuclear Society, v.53 no.1, 2021년, pp.199 - 207
Jeong, Manhee (Department of Nuclear and Energy Engineering, Jeju National University) , Kim, Geehyun (Department of Nuclear Engineering, Seoul National University)
This paper deals with accurate image reconstruction of gamma camera using a coded-aperture mask based on pixel-type CsI(Tl) scintillator coupled with silicon photomultipliers (SiPMs) array. Coded-aperture imaging (CAI) system typically has a smaller effective viewing angle than Compton camera. Thus,...
M.J. Cieslak, K.A.A. Gamage, R. Glover, Coded-aperture imaging systems: past, present and future development - a review, Radiat. Meas. 92 (2016) 59-71.
S. Joshi, Coded Aperture Imaging Applied to Pixelated CdZnTe Detectors, Ph.D. Thesis, University of Michigan, 2014.
N. Gehrels, G. Chincarini, et al., The swift gamma-ray burst mission, Astrophys. J. 611 (2) (2004) 1005-1020.
J. Hong, et al., Laboratory coded aperture imaging experiments: radial hole coded masks and depth-sensitive CZT detectors, in: Proceedings SPIE, Hard X-Ray and Gamma-Ray Detector Physics VI 5540, 2004, pp. 1-10.
E. Del Monte, E. Costa, et al., An X-ray imager based on silicon microstrip detector and coded mask, Nucl. Instrum. Methods Phys. Res. 576 (2007) 191-193.
M. Alnafea, K. Wells, et al., Preliminary results from a Monte Carlo study of breast tumour imaging with low-energy high-resolution collimator and a modified uniformly-redundant array-coded aperture, Nucl. Instrum. Methods Phys. Res. 563 (2006) 146-149.
A.L. Damato, B.K.P. Horn, R.C. Lanza, Coded source imaging for neutrons and X-rays, IEEE Nucl. Sci. Symp. Conf. Rec. (2007) 199-203.
A.A. Faust, R.E. Rothschild, et al., Development of a coded aperture X-Ray backscatter imager for explosive device detection, IEEE Trans. Nucl. Sci. 56 (1) (2009) 299-307.
M. Gmar, M. Agelou, F. Carrel, V. Schoepff, GAMPIX: a new generation of gamma camera, Nucl. Instrum. Methods Phys. Res. 652 (2011) 638-640.
S.R. Gottesman, E.E. Fenimore, New family of binary arrays for coded aperture imaging, Appl. Optic. 28 (20) (1989) 4344-4352.
S. Zelakiewicz, R. Hoctor, et al., SORIS-A standoff radiation imaging system, Nucl. Instrum. Methods Phys. Res. 652 (2011) 5-9.
S.J. Kaye, W.R. Kaye, Z. He, 4π coded aperture imaging using 3D position sensitive CdZnTe detectors, IEEE Nucl. Sci. Symp. Conf. Rec. (2008) 711-713.
S. Sun, Z. Zhang, et al., Development of a panorama coded-aperture gamma camera for radiation detection, Radiat. Meas. 77 (2015) 34-40.
E. Candes, J. Romberg, T. Tao, Robust uncertainty principles: exact signal reconstruction from highly incomplete frequency information, IEEE Trans. Inf. Theor. 52 (2006) 489-509.
D.L. Donoho, Compressed sensing, IEEE Trans. Inf. Theor. 52 (2006) 1289-1306.
R. Accorsi, Design of Near-Field Coded Aperture Camera for High Resolution Medical and Industrial Gamma Ray Imaging, Ph.D. Thesis, Massachusetts Institute of Technology, 2001.
M. Jeong, M.D. Hammig, Comparison of gamma ray localization using system matrixes obtained by either MCNP simulations or ray-driven calculations for a coded-aperture imaging system, Nucl. Instrum. Methods Phys. Res. 954 (2020) 161353..
E. Padovani, S.A. Pozzi, MCNP-PoliMi ver.1.0 User's Manual, CESNEF-021125, Library of Nuclear Engineering Department, Politecnico di Milano, November 2002.
M. Jeong, B. Van, B.T. Wells, L.J. D'Aries, M.D. Hammig, Scalable gamma-ray camera for wide-area search based on silicon photomultipliers array, Rev. Sci. Instrum. 89 (2018), 033106-033117.
J.K. Skinner, Imaging with coded-aperture masks, Nucl. Instrum. Methods Phys. Res. 221 (1984) 33-40.
A. Hammersley, T. Ponman, G. Skinner, Reconstruction of images from a coded-aperture box camera, Nucl. Instrum. Methods Phys. Res. 311 (1992) 585-594.
T. Ponman, A. Hammersley, G. Skinner, Error analysis for a noncyclic imaging system, Nucl. Instrum. Methods Phys. Res. 262 (1987) 419-429.
A. Hore, D. Ziou, Image quality metrics: PSNR vs. SSIM, Proc. ICPR 34 (2010) 2366-2367.
※ AI-Helper는 부적절한 답변을 할 수 있습니다.