In this study a test was conducted to identify weak section using 100kJ class rock energy to find out the protection performance of rockfall prevention fences in Korea. Performance rating of the rockfall protection fences is very low (48~61kJ) compared to that of foreign countries and it is necessar...
Bae, G. J., Koo, H. B. and Baek, Y. (2002), Study on suggestion a standard installation for damage reduction alarm system using cut-slope data, The journal of engineering geology, Vol. 12 No. 1, pp. 53~61.
EOTA (2012), ETAG 027 Guidline for European Technical Approval of Falling Protection Kits.
Korea Institute of Civil Engineering and Building Technology (1999), Development and Operation of Road Cut Slope Management System, II, Ministry of Land, Transport and Maritime Affairs.
Ministry of Construction and Transportation Guide (2000), Road Safety Facility Installation and Management Guidelines, Rockfall protection fence facility, pp. 1~84.
Ministry of Land, Transport and Maritime Affairs (2008), Installation and Management Guidelines of Road Safety Facilities -Rockfall Fence, Ministry of Land, Transport and Maritime Affairs.
Moon, B. K., Ha, J. J., Ko, M. K., and Kim, K. D. (2013), Performance Assessment and Improvement Scheme for Domestic Rockfall Barriers, Korean Society of Hazard Mitigation, pp. 220.
Tracker. (2022), Video Analysis and Modeling Tool, https://physlets.org/tracker/