NTIS 바로가기한국방사선학회 논문지 = Journal of the Korean Society of Radiology, v.16 no.4, 2022년, pp.387 - 394
윤준 (동남보건대학교 방사선학과) , 김현주 (동남보건대학교 방사선학과)
120 kVp FBP reconstruction image standard by using raw data after scanning by changing tube voltage among the NECK CT protocols that are broad applied in clinical practice using a human phantom including thyroid gland The usefulness of the DLIR reconstruction technique was investigated. As a result,...
Y. Y. Lee, P. Van Tassel, C. Nauert, L. B. North, B. S. Jing, "Lymphomas of the head and neck: CT findings at initial presentation", American Journal of Roentgenology, Vol. 149, No. 3, pp. 575-581, 1987. http://dx.doi.org/10.2214/ajr.149.3.575
M. Y. Park, S. E. Jung, "CT radiation dose and radiation reduction strategies", Journal of the Korean Medical Association, Vol. 54, No. 12, pp. 1262-1268, 2011. http://dx.doi.org/10.5124/jkma.2011.54.12.1262
S. Y. Cha, J. Y. Park, Y. K. Lee, J. H. Kim, J. H. Choi, "Quality of Image and Exposure Dose According to kVp, mA and Iterative Reconstruction in Computed Tomography", Journal of Radiological Science and Technology, Vol. 40, No. 3, pp. 385-391, 2017. https://doi.org/10.17946/JRST.2017.40.3.05
J. M. Oh, H. J. Seo, Y. K. Kim, D. K. Han, "Evaluation of Image Quality and Radiation Dose for Filtered Back-Projection and Iterative Reconstruction Algorithm in Abdominal Computed Tomography Protocol", Journal of the Korean Society of Radiology, Vol. 15, No. 7, pp. 1065-1072, 2021. https://doi.org/10.7742/JKSR.2021.15.7.1065
C. K. Park, K. S. Choo, J. H. Kim, K. J. Nam, J. W. Lee, J. Y. Kim, "Image quality and radiation dose in CT venography using model-based iterative reconstruction at 80 kVp versus adaptive statistical iterative reconstruction-V at 70 kVp", Korean Journal of Radiology, Vol. 20, No. 7, pp. 1167-1175, 2019. https://doi.org/10.3348/kjr.2018.0897
M. J. Willemink, P. B. Noel, "The evolution of image reconstruction for CT-from filtered back projection to artificial intelligence", European Radiology, Vol. 29, No. 5, pp. 2185-2195, 2019. http://dx.doi.org/10.1007/s00330-018-5810-7
L. L. Geyer, U. J. Schoepf, F. G. Meinel, J. W. Jr Nance, G. Bastarrika, J. A. Leipsic, N. S. Paul, M. Rengo, A. Laghi, C. N. De Cecco, "State of the Art: Iterative CT Reconstruction Techniques", Radiology, Vol. 276, No. 2. pp. 339-396, 2015. http://dx.doi.org/10.1148/radiol.2015132766
C. S. Ko, I. W. Cho, J. W. Kang, W. J. Jung, H. Song, "Study About Comparative Analysis and Usefulness By Quantitative Evaluation of Deep Learning Image Reconstruction and Adaptive Statistical Iterative Reconstruction-V in Aortic Vessels CT", Journal of Korean Society of Computed Tomographic Technology, Vol. 23, No. 2, pp. 9-19, 2021.
R. Miyajima, T. Fujibuch, Y. Miyachi, S. Tateishi, Y. Uno, K. Amakawa, H. Ohura, S. Orita, "Effective Techniques to Reduce Radiation Exposure to Medical Staff during Assist of X-ray Computed Tomography Examination", Journal of Nihon Hoshasen Gijutsu Gakkai, Vol. 74, No. 4, pp. 326-334, 2018. http://dx.doi.org/10.6009/jjrt.2018_JSRT_74.4.326
International Commission on Radiological Protection, "Managing Patient Dose in Computed tomography", ICRP Publication 87, Vol. 30, No. 4, pp. 1-41, 2000.
International Commission on Radiological Protection. "The 2007 Recommendations of the International Commission on Radiological Protection", ICRP Publication 103, Vol. 37, No. 2-4, pp. 1-399, 2007.
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
Free Access. 출판사/학술단체 등이 허락한 무료 공개 사이트를 통해 자유로운 이용이 가능한 논문
※ AI-Helper는 부적절한 답변을 할 수 있습니다.