김완호 (Dept. of Civil and Environment Engineering, Daejin Univ.) , 신유석 (Leader enc) , 이영진 (Dept. of Construction and Environmental Engineering, Daejin Univ.) , 장용채 (Dept. of Ocean Civil Engineering, Mokpo National Maritime Univ.) , 이강일 (Dept. of Smart Construction and Environmental Engineering, Daejin Univ.)
In areas where excavation works are carried out, it is very important to select a retaining wall method to minimize ground water level and ground subsidence changes. In this regard, the use of Secant Pile Wall(SPW) method, which can complement the disadvantages of the CIP method, is gradually domest...
Choi, J. S. and Yoon, E. J. (2007), Review of CIP Construction?Applicability of Excellent-Joint Pile with Improved Order?Performance and Vertical Continuous Drilling Function,?Proceedings of the Regular Academic Conference of the?Korean Society of Civil Engineers, pp.850-853.
Choi, Y. Y. (2010), Practical Verifications for the Advanced?Retaining Walls of Waterproofing and Structural Characteristics, Master's thesis, Seo-Kyeong University.
Ito, T. and Matsui, T. (1975), "Method to Estimate Lateral?Force Acting on Stabilizing Piles", Japanese Society of Soil?Mechanics and Foundation Engineering, Soils and Foundations,?Vol.15, No.4, pp.43-59.
Ministry of Land, Infrastructure and Transport (2016), Standard?Specification for Construction, KCS 21 00 00, pp.83-112.
Peng, F. L., Wang, H. L., Tan, Y., Xu, Z. L. and Li, Y. L.?(2011). "Field Measurements and Finite-Element Method-Simulation of a Tunnel Shaft Constructed by Pneumatic?Caisson Method in Shanghai Soft Ground", J. Geotech.?Geoenvironmental Eng., Vol.137, No.5, pp.516-524.
Shin, Y. S., Shin, Y. J., Yoo, J. H., Lee, Y. J. and Lee, K.?I. (2020a), "Study on the Foundation of RF-CIP using Guide?Beam", Korean Geotechnical Society Fall National Conference,?Online, pp.243-244.
Shin, Y. S., Yoo, J. H., Hwang, T. H., Lee, Y. J. and Lee,?K. I.(2020b), "A Study on the Stiffness Evaluation of RF CIP?Walls Using 3D Finite Element Analysis", Korean Geosynthetics Society Fall Geosynthetics Conference, Online, pp.80-81.
Sim, J. U., Son, S. G., Choi, J. S., Yoon, E. J. and Yoon,?S. J. (2008), "A Study on Strength and Waterproofing Characteristics of Excellent-Joint Pile(New Cast In Place Pile?Method)", Proc. of the Korean Society of Civil Engineers?Conference, Seoul, Vol.2008, pp.917-920.
Wharmby, N. (2010), "Development of Secant Pile Retaining?Wall Construction in Urban New Zealand", In Proc. of New?Zealand Concrete Industry Conference, Wellington, New?Zealand.
Yoon, T. K., Shin, Y. S., Choi, S. W. and Lee, K. I. (2022),?"A Study on the Improvement of the Waterproof Method?Overlapping CIP Method Using Steel Guide Blocks", Korean?Geosynthetics Society Spring Geosynthetics Conference,?Gyeonggi-do, pp.49-50.?
※ AI-Helper는 부적절한 답변을 할 수 있습니다.