NTIS 바로가기한국구조물진단유지관리공학회 논문집 = Journal of the Korea Institute for Structural Maintenance and Inspection, v.27 no.2, 2023년, pp.25 - 32
서유재 (한경국립대학교 건축학부 건축공학전공) , 주현진 (한경국립대학교 디자인건축융합학부)
In this study, a double wall system is introduced, which was invented to simplify the complicated manufacturing process of the existing precast concrete (PC) double wall systems and to remove defects such as laitance that may occur during the production of concrete panels. An experimental study was ...
Choi, H. B., Kim, H. S., Seo, D. S., and Kang, K. I. (2003), The?Study on the Capability Transform and Alternative Plan of?Reinforcing Bar with Straightening after Bending, Journal of the?Architectural Institute of Korea, 19(9), 181-188.
Ji, K. H., and Choi, B. J. (2019), Improvement of Underground?Wall Design and Construction Safety Using Mega Double Wall?Construction Method, Journal of the Korean Society of Hazard?Mitigation, 19(1), 1-12.
Jiang, J., Luo, J., Xue, W., Hu, X., and Qin, D. (2022),?Experimental study on Hysteresis Behavior of Precast Concrete?Double Skin Shear Wall with Horizontal Loop Connection and?Spiral-confined Vertical Lap Connection, Journal of Building?Engineering, 45, 103526.
KDS 14 20 54 (2021), Standard for Durability Design of Concrete?Structures, Korea Concrete Institute, Korea.
KS B 1002 (2021), Hexagon Head Bolts and Hexagon Head?Screws, Korea Agency for Technology and Standards, Korea.
KS D 3568 (2018), Carbon Steel Square Pipes for General?Structural Purposes, Korea Agency for Technology and Standards,?Korea.
Kim, S., Lee, D. E., Kim, Y., and Kim, S. (2020), Development and?Application of Precast Concrete Double Wall System to Improve?Productivity of Retaining Wall Construction. Sustainability,?12(8), 3454.
Lee, W. J., Kim, M., Lee, D., Ju, H., and Kim, K. H. (2022), Seismic?Performance Evaluation of Intermediate Precast Structural Walls,?The Journal of Next-generation Convergence Technology?Association, 6(3), 421-432.
Oh, Y. H., Moon, J. H., Kim, J. K., Lee, J. H., and Shin, S. H.?(2020), Evaluation of Structural Performance for Precast Concrete?Double-wall with Different Aspect Ratios and Joint Rebar Ratios,?Journal of the Korea Concrete Institute, 32(5), 445-455.
Park, Y. S. (2021), PC DW: Precast Double Wall, 3SW: Stable,?Strong, Sustainable, Magazine of the Korea Concrete Institute,?33(5), 59-61.