NTIS 바로가기한국지진공학회논문집 = Journal of the Earthquake Engineering Society of Korea, v.27 no.2, 2023년, pp.91 - 99
라지불 이슬람 (공주대학교 건설환경공학과) , 수딥타 차크라보르티 (공주대학교 건설환경공학과) , 공병진 (공주대학교 건설환경공학과) , 김두기 (공주대학교 스마트인프라공학과)
Structural vibration induced by earthquake hazards is one of the most significant concerns in structure performance-based design. Structural hazards evoked from seismic events must be properly identified to make buildings resilient enough to withstand extreme earthquake loadings. To investigate the ...
Cando MA, Hube MA, Parra PF, Arteta CA. Effect of stiffness on the?seismic performance of code-conforming reinforced concrete shear?wall buildings. Engineering Structures. 2020;219:110724. DOI:https://doi.org/10.1016/j.engstruct.2020.110724.
Xue Q, Wu CW, Chen CC, Chen KC. The draft code for performance-based seismic design of buildings in Taiwan. Engineering?Structures. 2008;30(6):1535-1547. DOI:https://doi.org/10.1016/j.engstruct.2007.10.002.
Kircher C, Deierlein G, Hooper J, Krawinkler H, Mahin S, Shing B,?Wallace J. Evaluation of the FEMA P-695 methodology for?quantification of building seismic performance factors. c2010.
Wu X, Guo W, Hu P, Bu D, Xie X, Hu Y. Seismic performance evaluation of building-damper system under near-fault earthquake. Shock and Vibration. c2020. DOI:https://doi.org/10.1155/2020/2763709.
Nazri FM. Predicting the collapse potential of structures in earthquakes. Doctoral dissertation. University of Bristol. c2011.
American Society of Civil Engineers. Minimum design loads and?associated criteria for buildings and other structures (ASCE 7-16).?American Society of Civil Engineers. c2017.
National Earthquake Hazards Reduction Program (US), & Building?Seismic Safety Council (US). NEHRP Recommended Provisions?(National Earthquake Hazards Reduction Program) for Seismic?Regulations for New Buildings and Other Structures. Building?Seismic Safety Council. c2001.
FEMA 356, F. E. Prestandard and commentary for the seismic?rehabilitation of buildings. Federal Emergency Management Agency:?Washington, DC, USA. c2000.
Ibrahim YE, El-Shami MM. Seismic fragility curves for mid-rise?reinforced concrete frames in Kingdom of Saudi Arabia. The IES?Journal Part A: Civil & Structural Engineering. 2011;4(4):213-223.?DOI:https://doi.org/10.1080/19373260.2011.609325.
Kassem MM, Nazri FM, Farsangi EN. On the quantification of?collapse margin of a retrofitted university building in Beirut using?a probabilistic approach. Engineering Science and Technology, an?International Journal. 2020;23(2):373-381. DOI:https://doi.org/10.1016/j.jestch.2019.05.003.
Ozkul TA, Kurtbeyoglu A, Borekci M, Zengin B, Kocak A. Effect of?shear wall on seismic performance of RC frame buildings. Engineering Failure Analysis. 2019;100:60-75. DOI:https://doi.org/10.1016/j.engfailanal.2019.02.032.
Tiwari P, Badal P, Suwal R. Effectiveness of fluid viscous dampers?in the seismic performance enhancement of RC buildings. Asian?Journal of Civil Engineering. 2022:1-10. DOI:https://doi.org/10.1007/s42107-022-00504-1.
Rakesh, B., & KS, S. S. K. M. N. Seismic Analysis of Tall Structures?by using Dampers in Etabs. c2022.
Guneyisi EM, Altay G. Seismic fragility assessment of effectiveness?of viscous dampers in R/C buildings under scenario earthquakes.?Structural Safety. 2018;30(5):461-480. DOI:https://doi.org/10.1016/j.strusafe.2007.06.001.
Zhang W, Liu S, Shokrabadi M, Dehghanpoor A, Taciroglu E.?Nonlinear seismic fragility assessment of tall buildings equipped?with tuned mass damper (TMD) and considering soil-structure?interaction effects. Bulletin of Earthquake Engineering. 2022:1-15.?DOI:https://doi.org/10.1007/s10518-022-01363-6.
De Domenico D, Ricciardi G. Earthquake-resilient design of base?isolated buildings with TMD at basement: Application to a case?study. Soil Dynamics and Earthquake Engineering. 2018;113:503-521. DOI:https://doi.org/10.1016/j.soildyn.2018.06.022.
Huang L, Clayton PM, Zhou Z. Seismic design and performance of?self-centering precast concrete frames with variable friction?dampers. Engineering Structures. 2021;245:112863. DOI:https://doi.org/10.1016/j.engstruct.2021.112863.
Reggio A, Angelis MD. Optimal energy-based seismic design of non-?conventional Tuned Mass Damper (TMD) implemented via inter-?story isolation. Earthquake Engineering & Structural Dynamics.?2015;44(10):1623-1642. DOI:https://doi.org/10.1002/eqe.2548.
Lee CH, Kim J, Kim DH, Ryu J, Ju YK. Numerical and experimental?analysis of combined behavior of shear-type friction damper and?non-uniform strip damper for multi-level seismic protection.?Engineering Structures. 2016;114:75-92. DOI:https://doi.org/10.1016/j.engstruct.2016.02.007.
Charkaborty S, Islam MR, Kim, D. Structural Performance Assessment of Buildings Considering Beam Discontinuity and Horizontal?Irregularity under Wind and Earthquake Loads. Journal of the?Korea Institute for Structural Maintenance and Inspection. 2022;26(5):10-19. https://doi.org/10.11112/JKSMI.2022.26.5.10.
Armali M, Damerji H, Hallal J, Fakih M. Effectiveness of friction?dampers on the seismic behavior of high rise building VS shear wall?system. Engineering Reports. 2019;1(5):e12075. DOI:https://doi.org/10.1002/eng2.12075.