최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기Journal of technologic dentistry : JTD, v.45 no.2, 2023년, pp.31 - 38
이혁준 (고려대학교 일반대학원 보건과학과 치의기공학전공) , 이하빈 (고려대학교 일반대학원 보건과학과 치의기공학전공) , 노미준 (고려대학교 일반대학원 보건과학과 치의기공학전공) , 김지환 (고려대학교 일반대학원 보건과학과 치의기공학전공)
Purpose: This in vitro study aimed to compare the trueness of 3-unit fixed dental provisional prostheses (FDPs) fabricated by three different additive manufacturing and subtractive manufacturing procedures. Methods: A reference model with a maxillary left second premolar and the second molar prepped...
Ehrenberg D, Weiner GI, Weiner S. Long-term effects of storage and thermal cycling on the marginal adaptation of provisional resin crowns: a pilot study. J Prosthet Dent 2006;95:230-236.?
Rakhshan V. Marginal integrity of provisional resin restoration materials: a review of the literature. Saudi J Dent Res. 2015;6:33-40.?
Tom TN, Uthappa MA, Sunny K, Begum F, Nautiyal M, Tamore S. Provisional restorations: an overview of materials used. J Adv Clin Res Insights. 2016;3:212-214.?
Alharbi N, Osman R, Wismeijer D. Effects of build direction on the mechanical properties of 3D-printed complete coverage interim dental restorations. J Prosthet Dent. 2016;115:760-767.?
Abdullah AO, Tsitrou EA, Pollington S. Comparative in vitro evaluation of CAD/CAM vs conventional provisional crowns. J Appl Oral Sci. 2016;24:258-263.?
Beuer F, Schweiger J, Edelhoff D. Digital dentistry: an overview of recent developments for CAD/CAM generated restorations. Br Dent J. 2008;204:505-511.?
van Noort R. The future of dental devices is digital. Dent Mater. 2012;28:3-12.?
Khaledi AA, Farzin M, Akhlaghian M, Pardis S, Mir N. Evaluation of the marginal fit of metal copings fabricated by using 3 different CAD-CAM techniques: milling, stereolithography, and 3D wax printer. J Prosthet Dent. 2020;124:81-86.?
Torabi K, Farjood E, Hamedani S. Rapid prototyping technologies and their applications in prosthodontics, a review of literature. J Dent (Shiraz). 2015;16:1-9.?
Choi EJ, Kim SA, Bae JY, Kwon YJ, Lee KH. A study on the state-of-the-art of 3D printers. Proc Korean Soc Comput Inf Conf. 2013;21:385-388.?
Kang W, Lee HK. A study of three-dimensional evaluation of the accuracy of resin provisional restorations fabricated with the DLP printer. J Korean Acad Dent Technol. 2020;42:35-41.?
Lee JS, LEE JJ. A study on the development of fashion design based on FDM 3D printing. J Korean Soc Fash Des. 2016;16:101-115.?
Moon W, Kim S, Lim BS, Park YS, Kim RJ, Chung SH. Dimensional accuracy evaluation of temporary dental restorations with different 3D printing systems. Materials (Basel). 2021;14:1487.?
Jo KH, Jang HS, Ha YM, Lee SH. Development of high-performance, low-cost 3D printer using LCD and UVLED. J Korean Soc Precis Eng. 2015;32:917-923.?
Kim HD. Application of 3D printer in dental clinic. J Korean Acad Esthet Dent. 2018;27:82-96.?
Yu BY, Son K, Lee KB. Evaluation of intaglio surface trueness and margin quality of interim crowns in accordance with the build angle of stereolithography apparatus 3-dimensional printing. J Prosthet Dent. 2021;126:231-237.?
Alharbi N, Alharbi S, Cuijpers VMJI, Osman RB, Wismeijer D. Three-dimensional evaluation of marginal and internal fit of 3D-printed interim restorations fabricated on different finish line designs. J Prosthodont Res. 2018;62:218-226.?
Grajower R, Zuberi Y, Lewinstein I. Improving the fit of crowns with die spacers. J Prosthet Dent. 1989;61:555-563.?
Hung SH, Hung KS, Eick JD, Chappell RP. Marginal fit of porcelain-fused-to-metal and two types of ceramic crown. J Prosthet Dent. 1990;63:26-31.?
Huh JB, Park CG, Kim HY, Park CK, Shin SW. Evaluation using replica technique on the marginal and internal fitness of zirconia cores by several CAD/CAM systems. J Korean Acad Prosthodont. 2010;48:135-142.?
Lee H, Lee DH, Lee KB. In vitro evaluation methods on adaptation of fixed dental prosthesis. J Dent Rehabil Appl Sci. 2017;33:63-70.?
Kim RJ, Park JM, Shim JS. Accuracy of 9 intraoral scanners for complete-arch image acquisition: a qualitative and quantitative evaluation. J Prosthet Dent. 2018;120:895-903.e1.?
Hamza TA, Ezzat HA, El-Hossary MM, Katamish HA, Shokry TE, Rosenstiel SF. Accuracy of ceramic restorations made with two CAD/CAM systems. J Prosthet Dent. 2013;109:83-87.?
Cho BM, Lee DJ. A study on cutting characteristics according to cutting direction in ball-end milling. Trans Korean Soc Mach Tool Eng. 2007;16:191-197.?
Cho BM, Yoo IS, Lee DJ. A study on the geometric characteristics according to semi-cylindrical tool path in ball-end milling. Paper presented at: Annual Spring Conferences of the 2009 Korean Society of Machine Tool Engineers; 2009 May 7-8; Seoul, Korea. Seoul: Korean Society of Manufacturing Technology Engineers, 2009. p. 362-367.?
Schaefer O, Kuepper H, Thompson GA, Cachovan G, Hefti AF, Guentsch A. Effect of CNC-milling on the marginal and internal fit of dental ceramics: a pilot study. Dent Mater. 2013;29:851-858.?
Shin GS, Kweon HK, Kang YG. The influence of experiment variables on DLP 3D printing using ART resin. J Korean Soc Manuf Process Eng. 2017;16:101-108.?
Shin GS, Kweon HK, Kang YG. Study on hardness of DLP 3D printer according to wavelength and light power. Paper presented at: 2018 Korean Society of Manufacturing Process Engineers Spring Conference; 2018 Apr 19-20; Yeosu, Korea. Daegu: Korean Society of Manufacturing Process Engineers, 2018. p. 182.?
Noh MJ, Lee HB, Kim JH. Evaluation of marginal and internal accuracy of provisional crowns manufactured using digital light processing three-dimensional printer. J Tech Dent. 2022;44:31-37.?
Kim CM, Kim SR, Kim JH, Kim HY, Kim WC. Trueness of milled prostheses according to number of ball-end mill burs. J Prosthet Dent. 2016;115:624-629.?
Kim DY, Jeon JH, Kim JH, Kim HY, Kim WC. Reproducibility of different arrangement of resin copings by dental microstereolithography: evaluating the marginal discrepancy of resin copings. J Prosthet Dent. 2017;117:260-265.?
Berger U. Aspects of accuracy and precision in the additive manufacturing of plastic gears. Virtual Phys Prototyp. 2015;10:49-57.?
Christensen GJ. The state of fixed prosthodontic impressions: room for improvement. J Am Dent Assoc. 2005;136:343-346.?
Ahn JJ, Huh JB, Choi JW. In vitro evaluation of the wear resistance of provisional resin materials fabricated by different methods. J Korean Acad Prosthodont. 2019;57:110-117.?
Cho WT, Choi JW. Comparison analysis of fracture load and flexural strength of provisional restorative resins fabricated by different methods. J Korean Acad Prosthodont. 2019;57:225-231.?
McLean JW. Polycarboxylate cements. Five years' experience in general practice. Br Dent J. 1972;132:9-15.?
Assif D, Rimer Y, Aviv I. The flow of zinc phosphate cement under a full-coverage restoration and its effect on marginal adaptation according to the location of cement application. Quintessence Int. 1987;18:765-774.?
Gulker I. Margins. N Y State Dent J. 1985;51:213-215, 217.?
Kim DY, Kim JH, Kim HY, Kim WC. Comparison and evaluation of marginal and internal gaps in cobalt-chromium alloy copings fabricated using subtractive and additive manufacturing. J Prosthodont Res. 2018;62:56-64.?
Pyo SW, Lee JJ, Han JS, Lim YJ. Study on methodology for the assessment of internal and marginal adaptation on fixed dental prosthesis. J Dent Rehabil Appl Sci. 2016;32:158-168.?
Stappert CF, Dai M, Chitmongkolsuk S, Gerds T, Strub JR. Marginal adaptation of three-unit fixed partial dentures constructed from pressed ceramic systems. Br Dent J. 2004;196:766-770; discussion 760, quiz 780.?
Tinschert J, Natt G, Mautsch W, Spiekermann H, Anusavice KJ. Marginal fit of alumina-and zirconia-based fixed partial dentures produced by a CAD/CAM system. Oper Dent. 2001;26:367-374.?
Groten M, Axmann D, Probster L, Weber H. Determination of the minimum number of marginal gap measurements required for practical in-vitro testing. J Prosthet Dent. 2000;83:40-49.?
Kim JH, Jeong JH, Lee JH, Cho HW. Fit of lithium disilicate crowns fabricated from conventional and digital impressions assessed with micro-CT. J Prosthet Dent. 2016;116:551-557.?
Bae SY, Park JY, Jeong ID, Kim HY, Kim JH, Kim WC. Three-dimensional analysis of marginal and internal fit of copings fabricated with polyetherketoneketone (PEKK) and zirconia. J Prosthodont Res. 2017;61:106-112.?
Kim KB, Jung JK, Kim JH. Accuracy of digital impression made from different elastomeric impression materials: three-dimensional superimpositional analysis. J Dent Hyg Sci. 2014;14:94-100.?
Schaefer O, Watts DC, Sigusch BW, Kuepper H, Guentsch A. Marginal and internal fit of pressed lithium disilicate partial crowns in vitro: a three-dimensional analysis of accuracy and reproducibility. Dent Mater. 2012;28:320-326.
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
오픈액세스 학술지에 출판된 논문
※ AI-Helper는 부적절한 답변을 할 수 있습니다.