최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기Korean chemical engineering research = 화학공학, v.61 no.4, 2023년, pp.576 - 583
시키 (경상국립대학교 화학공학과 및 그린에너지 연구소) , 셀바라잔 바르시니 (경상국립대학교 화학공학과 및 그린에너지 연구소) , 양영일 (경상국립대학교 반도체공학과) , 김혁한 (단국대학교 과학기술대학 화학과) , 김창준 (경상국립대학교 화학공학과 및 그린에너지 연구소)
This study aimed to investigate the impact of enhancing the electrode conductivity and mitigating the production of hydrogen peroxide - a by-product arising from lactate oxidation - on the performance of lactate electrodes. The electrical conductivity of the electrode was improved by modifying the s...
Rathee, K., Dhull, V., Dhull, R., Singh, S., "Biosensors Based on Electrochemical Lactate Detection: A Comprehensive Review," Biochem. Biophys. Rep., 5, 35-54(2016).?
Madden, J., Vaughan, E., Thompson, M., Riordan, A.O., Galvin, P., Lacopino, D. and Teixeira, S.R., "Electrochemical Sensor for Enzymatic Lactate Detection Based on Laser-scribed Graphitic Carbon Modified with Platinum, Chitosan and Lactate Oxidase," Talanta, 246, 123492(2022).?
Derbyshire, P. J., Barr, H., Davis, F. and Higson, S. P., "Lactate in Human Sweat: A Critical Review of Research to the Present Day," J. Physiol. Sci., 62, 429-440(2012).?
Chung, M., Fortunato, G. and Radacsi, N., "Wearable Flexible Sweat Sensors for Healthcare Monitoring; A Review," J. R. Soc. Interface, 16, 20190217(2019).?
Kim, H. H., Yoo, J. and Choi, M. K., "Non-invasive Wearable Continuous Monitoring Sensors," Polym. Sci. Technol., 31, 286-290(2020).?
Nagamine, K., Mano, T., Nomura, A., Ichimura, Y., Izawa, R., Furusawa, H., Matsui, H., Kumaki, D. and Tokito, S., "Noninvasive Sweat-Lactate Biosensor Employing a Hydrogel-Based Touch Pad," Sci. Rep., 9, 10102(2019).?
He, W., Wang, C., Wang, H., Jian, M., Lu, W., Liang, X., Zhang, X., Yang, F. and Zhang, Y., "Integrated Textile Sensor Patch for Real-time and Multiplex Sweat Analysis," Sci. Adv., 5, eaax0649(2019).?
Hoovels, K. V., Xuan, X., Cuartero, M., Gijssel, M., Swaren, M. and Crespo, G. A., "Can Wearable Sweat Lactate Sensors Contrivute to Sports Physiology?," ACS Sens., 6, 3496-3508(2021).?
Rahman, M. M., Shiddiky, M. J. A., Rahman, M. A. and Shim, Y.-B., "A Lactate Biosensor Based on Lactate Dehydrogenase/Nicotinamide Adenine Dinucleotide (Oxidized Form) Immobilized on A Conducting Polymer/Multiwall Carbon Nanotube Composite Film," Anal Biochem., 384, 159-165(2009).?
Hiraka, K., Tsugawa, W., Asano, R., Yokus, M. A., Ikebukuro, K., Daniele, M. A. and Sode, K., "Rational Design of Direct Electron Transfer Type L-Lactate Dehydrogenase for The Development of Multiplexed Biosensor," Biosens. Bioelectron., 176, 112933(2021).?
Gamero, M., Pariente, F., Lorenzo, E. and Alonso, C., "Nanostructured Rough Gold Electrodes for the Development of Lactate Oxidase-Based Biosensors," Biosens. Bioelectron., 25, 2038-2044(2010).?
Choi, H., Yeo, M., Kang, Y., Kim, H. J., Park, S. G., Jang, E., Park, S. H., Kim, E. and Kang, S., "Lactate Oxidase/Catalase-Displaying Nanopaticles Efficiently Consume Lactate in The Tumor Microenvironment to Effectively Suppress Tumor Growth," J. Nanobiotechnol., 21, 5(2023).?
Andrus, L. P., Unruh, R., Wisniewski, N. A. and McShane, M. J., "Characterization of Lactate Sensors Based on Lactate Oxidase and Palladium Benzoporphyrin Immobilized in Hydrogels," Biosensors, 5, 398-416(2015).?
Pichardo, S., Gutierrez-Praena, D., Puerto, M., Sanchez, E., Grilo, A., Camean, A. M. and Jos, A., "Oxidative Stress Response to Carboxylic Acid Functionalized Single Wall Carbon Nanotubes on the Human Intestinal Cell Line Caco-2," Toxicol In Vitro, 26, 672-677(2012).?
Heller, A., "Electrical Connection of Enzyme Redox Centers to Electrodes," J. Phys. Chem., 96, 3579-3587(1992).?
Ammam, M. and Fransaer, J., "AC-Electrophoretic Deposition of Metalloenzymes: Catalase As A Case Study for The Sensitive and Selective Detection of H2O2," Sens. Actuators B: Chem., 160, 1063-1069(2011).?
Zamocky, M., Regelsberger, G., Jakopitsh, C. and Obinger, C., "The Molecular Peculiarities of Catalase-Peroxidases," FEBS Lett., 492, 177-182(2001).?
Quyang, T., Feldman, B. J. and Chen, K., "Stabilized Lactate Responsive Enzymes, Electrodes and Sensors, and Methods for Making and Using the Same," European Patent No. EP 3 307 164 B1(2016).?
Quyang, T., Feldman, B. J. and Chen, K., "Stabilized Lactate Responsive Enzymes, Electrodes and Sensors, and Methods for Making and Using the Same," U.S. Patent No. US2016/0362716 A1(2016).?
Koposova, E., Shumilova, G., Ermolenko, Y., Kisner, A., Offen-hausser, A. and Mourzina, Y., "Direct Electrochemistry of cyt C and Hydrogen Peroxide Biosensing on Oleylamine-And Citrate-Stabilized Gold Nanostructures," Sens. Actuators B: Chem., 207, 1045-1052(2015).?
Voitko, K., Toth, A., Demianenko, E., Dobos, G., Berke, B., Bakalinska, O., Grebenyuk, A., Tombacz, E., Kuts, V., Tarasenko, Y., Kartel, M. and Laszlo, K., "Catalytic Performance of Carbon Nanotubes in H2O2 Decomposition: Experimental and Quantum Chemical Study," J. Colloid Interface Sci., 437, 283-290(2015).?
Moreno, J., Kasai, K., David, M., Nakanishi, H. and Kasai, H., "Hydrogen Peroxide and Adsorption on Fe-Filled Single-Walled Carbon Nanotubes: A Theoretical Study," J. Phys.: Condens. Matter, 21, 064219(2009).?
Engel, P. S., Billups, W. E., Abmayr Jr, D. W., Tsvaygboym, K. and Wang, R., "Reaction of Single-Walled Carbon Nanotubes with Organic Peroxides," J. Phys. Chem. C, 112, 695-700(2008).?
Willey, J. M., Sherwood, L. M. and Woolverton, C. J., Prescott, Harley, and Klein's Microbiology, 7th ed., McGraw-Hill, New York, NY(2008).?
Payne, M. E., Zamarayeva, A., Pister, V. I., Yamamoto, N. A. D. and Arias, A. C., "Printed, Flexible Lactate Sensors: Design Considerations Before Performing On-Body Measurements," Sci. Rep., 9, 13720(2019).?
Bhalla, N., Jolly, P., Formisano, N. and Estrela, P., "Introduction to Biosensors," Essays Biochem., 60, 1-8(2016).?
Ibupoto, Z. H., Shah, S. M. U. A., Khun, K. and Willander, M., "Electrochemical L-Lactic Acid Sensor Based on Immobilized ZnO Nanorods with Lactate Oxidase," Sensors, 12, 2456-2466(2012).?
Cunha-Silva, H. and Arcos-Martinez, M. J., "Dual Range Lactate Oxidase-Based Screen Printed Amperometric Biosensor for Analysis of Lactate in Diversified Samples," Talanta, 188, 779-787(2018).?
Jiang, D., Xu, C., Zhang, Q., Ye, Y., Cai, Y., Li, K., Li, Y., Huang, X. and Wang, Y., "In-Situ Preparation of Lactate-Sensing Membrane for The Noninvasive And Wearable Analysis of Sweat," Biosens. Bioelectron., 210, 114303(2022).
※ AI-Helper는 부적절한 답변을 할 수 있습니다.