최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기Journal of clinical laboratory analysis, v.35 no.9, 2021년, pp.e23919 -
Qian, Xi‐Feng (Department of Clinical Laboratory Medicine, The Third Affiliated Hospital of Guangzhou Medical University, Guangzhou, China) , Duan, Ai‐Ling (Department of Clinical Laboratory Medicine, The Third Affiliated Hospital of Guangzhou Medical University, Guangzhou, China) , Huang, Rong‐Xian (Department of Clinical Laboratory Medicine, The Third Affiliated Hospital of Guangzhou Medical University, Guangzhou, China) , Li, Nan‐Xi (Department of Clinical Laboratory Medicine, The Third Affiliated Hospital of Guangzhou Medical University, Guangzhou, China) , Li, Ya‐Ping (Department of Clinical Laboratory Medicine, The Third Affiliated Hospital of Guangzhou Medical University, Guangzhou, China) , Guo, Xu‐Guang (Department of Clinical Laboratory Medicine, The Third Affiliated Hospital of Guangzhou Medical University, Guangzhou, China)
AbstractBackgroundRapid laboratory detection is essential to diagnose norovirus infection. LAMP has many advantages compared with RT‐PCR for detecting norovirus, including high sensitivity, high specificity, rapidity, low cost, and intuitive results, which can be easily read with the naked eye...
1 CDC Norovirus Worldwide . https://www.cdc.gov/norovirus/trends‐outbreaks/worldwide.html . Accessed April 4, 2021.
2 Kirk MD , Pires SM , Black RE , et al. World Health Organization estimates of the global and regional disease burden of 22 foodborne bacterial, protozoal, and viral diseases, 2010: a data synthesis . PLoS Med . 2015 ; 12 ( 12 ): e1001921 . 26633831
3 GBD 2016 Diarrhoeal Disease Collaborators . Estimates of the global, regional, and national morbidity, mortality, and aetiologies of diarrhoea in 195 countries: a systematic analysis for the Global Burden of Disease Study 2016 . Lancet Infect Dis . 2018 ; 18 ( 11 ): 1211 ‐ 1228 . 30243583
4 Havelaar AH , Kirk MD , Torgerson PR , et al. World Health Organization global estimates and regional comparisons of the burden of foodborne disease in 2010 . PLoS Med . 2015 ; 12 ( 12 ): e1001923 . 26633896
5 Ahmed SM , Hall AJ , Robinson AE , et al. Global prevalence of norovirus in cases of gastroenteritis: a systematic review and meta‐analysis . Lancet Infect Dis . 2014 ; 14 ( 8 ): 725 ‐ 730 . 24981041
6 Robilotti E , Deresinski S , Pinsky BA . Norovirus . Clin Microbiol Rev . 2015 ; 28 ( 1 ): 134 ‐ 164 . 25567225
7 de Graaf M , van Beek J , Koopmans MP . Human norovirus transmission and evolution in a changing world . Nat Rev Microbiol . 2016 ; 14 ( 7 ): 421 ‐ 433 . 27211790
8 Vinjé J . Advances in laboratory methods for detection and typing of norovirus . J Clin Microbiol . 2015 ; 53 ( 2 ): 373 ‐ 381 . 24989606
9 Platts‐Mills JA , Babji S , Bodhidatta L , et al. Pathogen‐specific burdens of community diarrhoea in developing countries: a multisite birth cohort study (MAL‐ED) . Lancet Glob Health . 2015 ; 3 ( 9 ): e564 ‐ e575 . 26202075
10 Kotloff KL , Nataro JP , Blackwelder WC , et al. Burden and aetiology of diarrhoeal disease in infants and young children in developing countries (the Global Enteric Multicenter Study, GEMS): a prospective, case‐control study . Lancet . 2013 ; 382 ( 9888 ): 209 ‐ 222 . 23680352
11 Liu L , Moore MD . A survey of analytical techniques for noroviruses . Foods . 2020 ; 9 ( 3 ): 318 .
12 Costantini V , Grenz L , Fritzinger A , et al. Diagnostic accuracy and analytical sensitivity of IDEIA Norovirus assay for routine screening of human norovirus . J Clin Microbiol . 2010 ; 48 ( 8 ): 2770 ‐ 2778 . 20554813
13 Wong YP , Othman S , Lau YL , Radu S , Chee HY . Loop‐mediated isothermal amplification (LAMP): a versatile technique for detection of micro‐organisms . J Appl Microbiol . 2018 ; 124 ( 3 ): 626 ‐ 643 . 29165905
14 Notomi T , Okayama H , Masubuchi H , et al. Loop‐mediated isothermal amplification of DNA . Nucleic Acids Res . 2000 ; 28 ( 12 ): E63 . 10871386
15 Fukuda S , Takao S , Kuwayama M , Shimazu Y , Miyazaki K . Rapid detection of norovirus from fecal specimens by real‐time reverse transcription‐loop‐mediated isothermal amplification assay . J Clin Microbiol . 2006 ; 44 ( 4 ): 1376 ‐ 1381 . 16597865
16 McInnes MDF , Moher D , Thombs BD , et al. Preferred reporting items for a systematic review and meta‐analysis of diagnostic test accuracy studies: the PRISMA‐DTA statement . JAMA . 2018 ; 319 ( 4 ): 388 ‐ 396 . 29362800
17 Leeflang MM . Systematic reviews and meta‐analyses of diagnostic test accuracy . Clin Microbiol Infect . 2014 ; 20 ( 2 ): 105 ‐ 113 . 24274632
18 Devillé WL , Buntinx F , Bouter LM , et al. Conducting systematic reviews of diagnostic studies: didactic guidelines . BMC Med Res Methodol . 2002 ; 2 : 9 . 12097142
19 Whiting PF , Rutjes AW , Westwood ME , et al. QUADAS‐2: a revised tool for the quality assessment of diagnostic accuracy studies . Ann Intern Med . 2011 ; 155 ( 8 ): 529 ‐ 536 . 22007046
20 Zamora J , Abraira V , Muriel A , Khan K , Coomarasamy A . Meta‐DiSc: a software for meta‐analysis of test accuracy data . BMC Med Res Methodol . 2006 ; 6 : 31 . 16836745
21 Huedo‐Medina TB , Sánchez‐Meca J , Marín‐Martínez F , Botella J . Assessing heterogeneity in meta‐analysis: Q statistic or I2 index? Psychol Methods . 2006 ; 11 ( 2 ): 193 ‐ 206 . 16784338
22 Higgins JP , Thompson SG . Quantifying heterogeneity in a meta‐analysis . Stat Med . 2002 ; 21 ( 11 ): 1539 ‐ 1558 . 12111919
23 Deeks JJ , Macaskill P , Irwig L . The performance of tests of publication bias and other sample size effects in systematic reviews of diagnostic test accuracy was assessed . J Clin Epidemiol . 2005 ; 58 ( 9 ): 882 ‐ 893 . 16085191
24 Fukuda S , Sasaki Y , Takao S . An application of RT‐LAMP assay for rapid detection of noroviruses . Kansenshogaku Zasshi . 2008 ; 82 ( 6 ): 654 ‐ 655 . 19086423
25 Iturriza‐Gómara M , Xerry J , Gallimore CI , Dockery C , Gray J . Evaluation of the Loopamp® (loop‐mediated isothermal amplification) kit for detecting Norovirus RNA in faecal samples . J Clin Virol . 2008 ; 42 ( 4 ): 389 ‐ 393 . 18394955
26 Chen ZF , Wang T , Huang ZX , Lin Y , Chen JY . Application of the reverse transcription loop‐mediated isothermal amplification technique in detection of Norovirus gene . Chin J Zoonoses . 2009 ; 25 ( 4 ): 340 ‐ 343 .
27 Luo JM , Wu XY , Xu ZQ , et al. Colorimetric detection of norovirus genotype GII by reverse transcription loop‐mediated isothermal amplification . Chin J Virol . 2012 ; 28 ( 02 ): 165 ‐ 171 .
28 Luo J , Xu Z , Nie K , et al. Visual detection of norovirus genogroup II by reverse transcription loop‐mediated isothermal amplification with hydroxynaphthol blue dye . Food Environ Virol . 2014 ; 6 ( 3 ): 196 ‐ 201 . 24752892
29 Zhang SH , Cui LB , Qi X , Fu JG , Xie GX , Zhang HY . Detection for norovirus genotype Ⅱ with RT‐LAMP. Modern . Prev Med . 2014 ; 41 ( 15 ): 2790 ‐2,9.
30 Suzuki W , Ohiro Y , Tsukagoshi H , Kimura H . Evaluation of norovirus detection method based on a newly developed bioluminescent enzyme immunoassay (BLEIA) system . Kansenshogaku Zasshi . 2015 ; 89 ( 2 ): 230 ‐ 236 . 26552119
31 Tan Z , Li S . Application of visual detection of norovirus GⅡ with reverse transcription loop‐mediated isothermal amplification in infectious diarrhea outbreaks . Chin J Health Lab Technol . 2017 ; 27 ( 22 ): 3236 ‐ 3238 .
32 Identifying and measuring heterogeneity . 2017 . http://handbook.cochrane.org/chapter_9/9_5_2identifyingandmeasuringheterogeneity.html . Accessed April 4, 2021.
33 Manuel CS , Moore MD , Jaykus LA . Predicting human norovirus infectivity – recent advances and continued challenges . Food Microbiol . 2018 ; 76 : 337 ‐ 345 . 30166159
34 Atmar RL , Ramani S , Estes MK . Human noroviruses: recent advances in a 50‐year history . Curr Opin Infect Dis . 2018 ; 31 ( 5 ): 422 ‐ 432 . 30102614
35 Shah MP , Hall AJ . Norovirus illnesses in children and adolescents . Infect Dis Clin North Am . 2018 ; 32 ( 1 ): 103 ‐ 118 . 29406972
36 Daskou M , Dimitriou TG , Kouklamani‐Giannouli G , et al. Development of a reverse transcription loop‐mediated isothermal amplification assay (RT‐LAMP) that detects enteroviruses by targeting the highly conserved 5'‐UTR region . Virus Genes . 2020 ; 56 ( 2 ): 194 ‐ 201 . 31955385
37 Cai ZH , Dai YY , Huang LY , Zhang WS , Guo XG . Diagnosis of mycoplasma pneumoniae by loop‐mediated isothermal amplification: systematic review and meta‐analysis . BMC Infect Dis . 2019 ; 19 ( 1 ): 173 . 30782134
38 Chen CM , Ouyang S , Lin LY , et al. Diagnostic accuracy of LAMP assay for HBV infection . J Clin Lab Anal . 2020 ; 34 ( 7 ): e23281 . 32157743
39 Fan SJ , Tan HK , Xu YC , et al. A pooled analysis of the LAMP assay for the detection of Neisseria meningitidis . BMC Infect Dis . 2020 ; 20 ( 1 ): 525 . 32689953
※ AI-Helper는 부적절한 답변을 할 수 있습니다.