NTIS 바로가기Magnetic resonance in medicine : official journal of the Society of Magnetic Resonance in Medicine, v.53 no.6, 2005년, pp.1393 - 1401
Bydder, Mark (Department of Radiology, Magnetic Resonance Institute, UCSD Medical Center, San Diego, California, USA) , Robson, Matthew D. (Department of Radiology, Magnetic Resonance Institute, UCSD Medical Center, San Diego, California, USA)
The techniques of partial Fourier (PF) and partially parallel imaging have been combined using a constrained reconstruction technique. The benefits compared with the individual techniques are reduced imaging time and/or an increase in signal-to-noise ratio. Low-resolution phase maps and coil sensiti...
Noll, D.C., Nishimura, D.G., Macovski, A.. Homodyne detection in magnetic resonance imaging. IEEE transactions on medical imaging, vol.10, no.2, 154-163.
McGibney, G., Smith, M. R., Nichols, S. T., Crawley, A.. Quantitative evaluation of several partial fourier reconstruction algorithms used in mri. Magnetic resonance in medicine : official journal of the Society of Magnetic Resonance in Medicine, vol.30, no.1, 51-59.
10.1002/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO;2-S
10.1002/1522-2594(200008)44:2<301::AID-MRM18>3.0.CO;2-D
WiesingerF PruessmannKP BoesigerP.Inherent limitation of the reduction factor in parallel imaging as a function of field strength. IN: Proceedings of the 10th Annual Meeting of ISMRM Honolulu 2002. p191.
Glover, Paul, Tokarczuk, Pawel F., Bowtell, Richard W.. A robust single‐shot partial sampling scheme. Magnetic resonance in medicine : official journal of the Society of Magnetic Resonance in Medicine, vol.34, no.1, 74-79.
10.1002/(SICI)1522-2594(199906)41:6<1236::AID-MRM21>3.0.CO;2-T
SodicksonDK StuberM BotnarRM KissingerKV ManningWJ.SMASH real‐time cardiac MR imaging at echocardiographic frame rates. In: Proceedings of the 9th Annual Meeting of ISMRM Glasgow Scotland 1999. p387.
KingKF AngelosL.SENSE with partial Fourier homodyne reconstruction. In: Proceedings of the 8th Annual Meeting of ISMRM Denver 2000. p153.
Kellman, Peter, Epstein, Frederick H., McVeigh, Elliot R.. Adaptive sensitivity encoding incorporating temporal filtering (TSENSE). Magnetic resonance in medicine : official journal of the Society of Magnetic Resonance in Medicine, vol.45, no.5, 846-852.
Griswold, Mark A., Jakob, Peter M., Heidemann, Robin M., Nittka, Mathias, Jellus, Vladimir, Wang, Jianmin, Kiefer, Berthold, Haase, Axel. Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magnetic resonance in medicine : official journal of the Society of Magnetic Resonance in Medicine, vol.47, no.6, 1202-1210.
Heidemann, R.M., Griswold, M.A., Kiefer, B., Nittka, M., Wang, J., Jellus, V., Jakob, P.M.. Resolution enhancement in lung 1H imaging using parallel imaging methods. Magnetic resonance in medicine : official journal of the Society of Magnetic Resonance in Medicine, vol.49, no.2, 391-394.
LiBS ChenQ LiW LingamneniA AngelosL PolzinJA EdelmanRR.Single‐shot FIESTA single‐breath‐hold whole‐heart MRI with 4X parallel imaging. In: Proceedings of the 11th Annual Meeting of ISMRM Toronto Canada 2003. p380.
10.1002/mrm.10599 KlarhoferM DilharreguyB van GelderenP MoonenC.A PRESTO SENSE sequence with alternating partial Fourier encoding for rapid 3D MRI time series. In: Proceedings of the 11th Annual Meeting of ISMRM Toronto Canada 2003. p740.
SamsonovAA KholmovskiEG.Method for quality improvement of images reconstructed from sensitivity encoded data. In: Proceedings of the 10th Annual Meeting of ISMRM Honolulu 2002. p2408.
Willig‐OnwuachiJD YehEN GrantAK OhligerMA McKenzieCA SodicksonDK.Phase‐constrained parallel MR image reconstruction using symmetry to increase acceleration and improve image quality. In: Proceedings of the 11th Annual Meeting of ISMRM Toronto Canada 2003. p19.
Numerical recipes in C Press WH 50 1992
Matrix computations Golub GH 410 1983
TakahashiA GloverGH.Half Fourier spiral image reconstruction. In: Proceedings of the 5th Annual Meeting of ISMRM Vancouver Canada 1997. p135.
HargreavesBA PaulyJM NishimuraDG.Comparison of even and odd projection‐reconstruction sampling strategies. In: Proceedings of the 7th Annual Meeting of ISMRM Philadelphia 1999. p658.
Pruessmann, Klaas P., Weiger, Markus, Börnert, Peter, Boesiger, Peter. Advances in sensitivity encoding with arbitrary k-space trajectories. Magnetic resonance in medicine : official journal of the Society of Magnetic Resonance in Medicine, vol.46, no.4, 638-651.
Robson, Matthew D., Gatehouse, Peter D., Bydder, Mark, Bydder, Graeme M.. Magnetic Resonance: An Introduction to Ultrashort TE (UTE) Imaging. Journal of computer assisted tomography, vol.27, no.6, 825-846.
BydderM.The use of robust methods to reduce image artefacts. In: Proceedings of the 11th Annual Meeting of ISMRM Toronto Canada 2003. p482.
Bydder, M., Larkman, D.J., Hajnal, J.V.. Detection and elimination of motion artifacts by regeneration of k-space. Magnetic resonance in medicine : official journal of the Society of Magnetic Resonance in Medicine, vol.47, no.4, 677-686.
Matej, S., Fessler, J.A., Kazantsev, I.G.. Iterative tomographic image reconstruction using Fourier-based forward and back-projectors. IEEE transactions on medical imaging, vol.23, no.4, 401-412.
Dydak, Ulrike, Weiger, Markus, Pruessmann, Klaas P., Meier, Dieter, Boesiger, Peter. Sensitivity-encoded spectroscopic imaging. Magnetic resonance in medicine : official journal of the Society of Magnetic Resonance in Medicine, vol.46, no.4, 713-722.
KingKF AngelosL.SENSE image quality improvement using matrix regularization. In: Proceedings of the 9th Annual Meeting of ISMRM Glasgow Scotland 2001. p1771.