최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기Energy and buildings, v.42 no.1, 2010년, pp.43 - 49
Liu, J. (School of Environmental Science and Technology, Tianjin University, Tianjin 300072, China) , Li, W. (School of Environmental Science and Technology, Tianjin University, Tianjin 300072, China) , Liu, J. (School of Environmental Science and Technology, Tianjin University, Tianjin 300072, China) , Wang, B.
The energy recovery ventilator (ERV) is an effective method, which can transfer heat and moisture from the exhaust air into the outdoor fresh air to save energy in buildings. Nowadays, ERV has been widely used in the commercial, industrial and residential buildings in China. Its energy saving perfor...
Energy and Buildings Juodis 38 6 568 2006 10.1016/j.enbuild.2005.07.002 Extracted ventilation air heat recovery efficiency as a function of a building's thermal properties
Applied Thermal Engineering Lazzarin 18 1-2 47 1998 10.1016/S1359-4311(97)00013-6 Technical and economical analysis of heat recovery in building ventilation systems
Energy Zhang 26 119 2006 10.1016/S0360-5442(00)00064-5 Energy requirements for conditioning fresh air and the long-term savings with a membrane-based energy recovery ventilator in Hong Kong
Journal of Membrane Science Niu 189 179 2001 10.1016/S0376-7388(00)00680-3 Membrane-based enthalpy exchanger: material considerations and clarification of moisture resistance
Energy and Buildings Roulet 33 5 495 2001 10.1016/S0378-7788(00)00104-3 Real heat recovery with air handling units
Journal of Tianjin University Science and Technology Liu 40 8 943 2007 Weighted coefficient method to analyze efficiency of total heat exchanger
International Journal of Heat and Mass Transfer Zhang 50 1-2 151 2007 10.1016/j.ijheatmasstransfer.2006.06.025 Heat and mass transfer in a cross-flow membrane-based enthalpy exchanger under naturally formed boundary conditions
ASME Journal of Heat Transfer Zhang 122 5 922 2002 10.1115/1.1469524 Effectiveness correlations for heat and moisture transfer processes in an enthalpy exchanger with membrane cores
Heat and Mass Transfer Dindore 48 3352 2005 10.1016/j.ijheatmasstransfer.2005.03.002 Gas-liquid mass transfer in a cross-flow hollow fiber module: analytical model and experimental validation
Energy and Buildings Zhou 39 12 1202 2007 10.1016/j.enbuild.2006.12.010 Performance of energy recovery ventilator with various weathers and temperature set-points
Journal of Membrane Science Zhang 163 29 1999 10.1016/S0376-7388(99)00150-7 Heat and mass transfer in a membrane-based energy recovery ventilator
Heat Recovery Systems and CHP Lukitobudi 15 5 481 1995 10.1016/0890-4332(95)90057-8 Construction and testing of a thermosyphon heat exchanger for medium temperature heat recovery in bakeries
Journal of Shijiazhuang Railway Institute Yang 5 1 64 1992 Total heat exchanger-a new type of energy saving equipment for air condition units
Zhao 1994 Air Condition
Lu 1993 Practical Design Handbook of Heating and Air Conditioning
U.S. Department of Energy, EnergyPlus Documentation, 2007.
Energy and Buildings Crawley 33 4 319 2001 10.1016/S0378-7788(00)00114-6 EnergyPlus: creating a new-generation building energy simulation program
Building and Environment Al-Homoud 36 4 421 2001 10.1016/S0360-1323(00)00026-3 Computer-aided building energy analysis techniques
Energy and Buildings Henninger 36 8 855 2004 10.1016/j.enbuild.2004.01.025 Analytical and comparative testing of EnergyPlus using IEA HVAC BESTEST E100-E200 test suite
U.S. Department of Energy, Weather Data of Energyplus Energy Simulation Software. http://www.eere.energy.gov/buildings/energyplus/cfm/weather_data3.cfm/region=2_asia_wmo_region_2/country=CHN/cname=China, 2007.
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.