The use of regular-sized dental implants is generally recommended to ensure adequate bone to implant contact. However, when the width of the edentulous crest is insufficient for the placement of a regular-sized implant, the use of a narrow-diameter implant (NDI) should be considered to prevent the n...
Int J Oral Maxillofac Implants Feine 17 601 2002 The McGill consensus statement on overdentures. Mandibular two-implant overdentures as first choice standard of care for edentulous patients. Montreal, Quebec, May 24-25, 2002
Int J Oral Maxillofac Implants Albrektsson 1 11 1986 The long-term efficacy of currently used dental implants: a review and proposed criteria of success
Int J Oral Maxillofac Implants Roos 12 504 1997 A qualitative and quantitative method for evaluating implant success: a 5-year retrospective analysis of the Branemark implant
Int J Periodontics Restorative Dent Froum 27 449 2007 Narrow-diameter implants: a restorative option for limited interdental space
Pract Periodontics Aesthet Dent Lazzara 6 55 1994 Criteria for implant selection: surgical and prosthetic considerations
Int J Oral Maxillofac Implants Qian 24 877 2009 Effects of implant diameter, insertion depth, and loading angle on stress/strain fields in implant/jawbone systems: finite element analysis
J Esthet Dent Davarpanah 12 186 2000 10.1111/j.1708-8240.2000.tb00221.x Small diameter implants: indications and contraindications
J Prosthet Dent Atwood 26 266 1971 10.1016/0022-3913(71)90069-2 Reduction of residual ridges: a major oral disease entity
J Prosthodont Razavi 4 90 1995 10.1111/j.1532-849X.1995.tb00322.x Anatomic site evaluation of edentulous maxillae for dental implant placement
Int J Periodontics Restorative Dent Schropp 23 313 2003 Bone healing and soft tissue contour changes following single-tooth extraction: a clinical and radiographic 12-month prospective study
Int J Oral Maxillofac Implants Schropp 18 189 2003 Bone healing following immediate versus delayed placement of titanium implants into extraction sockets: a prospective clinical study
Compendium Barber 15 1390,1392 1994 The role of the small-diameter dental implant: a preliminary report on the Miniplant system
Int J Oral Maxillofac Implants Andersen 16 217 2001 A prospective clinical study evaluating the safety and effectiveness of narrow-diameter threaded implants in the anterior region of the maxilla
Int J Oral Maxillofac Implants Morneburg 23 270 2008 Success rates of microimplants in edentulous patients with residual ridge resorption
Int J Oral Maxillofac Implants Reddy 23 281 2008 Initial clinical efficacy of 3-mm implants immediately placed into function in conditions of limited spacing
J Periodontol Degidi 79 1 2008 10.1902/jop.2008.070248 Clinical outcome of narrow diameter implants: a retrospective study of 510 implants
J Prosthet Dent Rieger 63 457 1990 10.1016/0022-3913(90)90238-8 A finite element survey of eleven endosseous implants
J Oral Implantol Matsushita 16 6 1990 Two-dimensional FEM analysis of hydroxyapatite implants: diameter effects on stress distribution
Int J Oral Maxillofac Surg Ivanoff 26 141 1997 10.1016/S0901-5027(05)80837-9 Influence of implant diameters on the integration of screw implants. An experimental study in rabbits
J Oral Rehabil Comfort 32 341 2005 10.1111/j.1365-2842.2004.01441.x 5-year prospective study on small diameter screw-shaped oral implants
Clin Oral Implants Res Arisan 21 296 2010 10.1111/j.1600-0501.2009.01840.x Evaluation of 316 narrow diameter implants followed for 5-10 years: a clinical and radiographic retrospective study
Int J Oral Maxillofac Implants Zinsli 19 92 2004 Clinical evaluation of small-diameter ITI implants: a prospective study
Clin Oral Implants Res Romeo 17 139 2006 10.1111/j.1600-0501.2005.01191.x Clinical and radiographic evaluation of small-diameter (3.3-mm) implants followed for 1-7 years: a longitudinal study
Int J Oral Maxillofac Implants Zechner 18 873 2003 Rotational panoramic versus intraoral rectangular radiographs for evaluation of peri-implant bone loss in the anterior atrophic mandible
Clin Oral Implants Res Allum 19 553 2008 10.1111/j.1600-0501.2007.01395.x The impact of loads on standard diameter, small diameter and mini implants: a comparative laboratory study
Implant Dent Mazor 13 336 2004 10.1097/01.id.0000148554.83439.00 Mini-implants to reconstruct missing teeth in severe ridge deficiency and small interdental space: a 5-year case series
Clin Oral Implants Res Lindh 6 96 1995 10.1034/j.1600-0501.1995.060205.x Measurements of distances related to the mandibular canal in radiographs
Clin Implant Dent Relat Res Geckili 14 e91 2012 10.1111/j.1708-8208.2011.00370.x The effect of maximum bite force, implant number, and attachment type on marginal bone loss around implant supporting mandibular overdentures: a retrospective study
Int J Oral Maxillofac Implants Cehreli 25 266 2010 A systematic review of marginal bone loss around implants retaining or supporting overdentures
J Prosthet Dent Smith 62 567 1989 10.1016/0022-3913(89)90081-4 Criteria for success of osseointegrated endosseous implants
Int J Prosthodont Albrektsson 6 95 1993 Current interpretations of the osseointegrated response: clinical significance
Compend Contin Educ Dent Saadoun 17 669 1996 An 8-year compilation of clinical results obtained with Steri-Oss endosseous implants
Clin Oral Implants Res Lazzara 7 73 1996 10.1034/j.1600-0501.1996.070109.x Retrospective multicenter analysis of 3i endosseous dental implants placed over a five-year period
J Clin Periodontol Meijer 31 522 2004 10.1111/j.1600-051X.2004.00510.x Mandibular overdentures supported by two Branemark, IMZ or ITI implants: a 5-year prospective study
Int J Oral Maxillofac Implants Jemt 8 635 1993 Oral implant treatment in posterior partially edentulous jaws: a 5-year follow-up report
Clin Oral Implants Res Ericsson 5 185 1994 10.1034/j.1600-0501.1994.050310.x Clinical and radiographical features of submerged and nonsubmerged titanium implants
Int J Prosthodont Jemt 16 415 2003 Implant-supported laser-welded titanium and conventional cast frameworks in the partially edentulous law: a 5-year prospective multicenter study
Int J Prosthodont Attard 17 417 2004 Long-term treatment outcomes in edentulous patients with implant-fixed prostheses: the Toronto study
Int J Prosthodont Carlsson 13 295 2000 Long-term marginal periimplant loss in edentulous patients
Clin Oral Implants Res Petrie 16 486 2005 10.1111/j.1600-0501.2005.01132.x Comparative evaluation of implant designs: influence of diameter, length, and taper on strains in the alveolar crest. A three-dimensional finite-element analysis
Clin Oral Implants Res Åstrand 15 413 2004 10.1111/j.1600-0501.2004.01028.x and Branemark system implants: a 5-year prospective study of marginal bone reactions
Implant Dent Bilhan 19 437 2010 10.1097/ID.0b013e3181f57110 Branemark, and ITI implants in the rehabilitation of partial edentulism: two-year results
Implant Dent Bilhan 19 250 2010 10.1097/ID.0b013e3181dc9d1a Influence of platform-switching on marginal bone levels for implants with mandibular overdentures: a retrospective clinical study
Int J Oral Maxillofac Implants Bahat 15 646 2000 Branemark system implants in the posterior maxilla: clinical study of 660 implants followed for 5 to 12 years
Int J Oral Maxillofac Implants Vigolo 19 703 2004 Clinical evaluation of small-diameter implants in single-tooth and multiple-implant restorations: a 7-year retrospective study
Int J Oral Maxillofac Implants Jemt 6 413 1991 In vivo load measurements on osseointegrated implants supporting fixed or removable prostheses: a comparative pilot study
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
출판사/학술단체 등이 한시적으로 특별한 프로모션 또는 일정기간 경과 후 접근을 허용하여, 출판사/학술단체 등의 사이트에서 이용 가능한 논문
※ AI-Helper는 부적절한 답변을 할 수 있습니다.