NTIS 바로가기International journal of refrigeration = Revbue internationale du froid, v.53, 2015년, pp.115 - 125
In this study, the performance of an R22 refrigeration system of 9.6 kW cooling capacity injecting vapor and liquid refrigerant to compressor inlet through accumulator is analyzed at high compression ratio experimentally. Results obtained in this study are compared and discussed for better performan...
Afjei 1992 International Compressor Engineering Conference Experimental analysis of an inverter-driven scroll compressor with liquid injection
ASHRAE Guideline 2 1986 Engineering Analysis of Experimental Data
Int. J. Refrigeration Chen 25 751 2002 10.1016/S0140-7007(01)00072-X Mathematical modeling of scroll compressor part II: overall scroll compressor modeling
Int. J. Refrigeration Cho 26 87 2003 10.1016/S0140-7007(02)00017-8 Influence of liquid refrigerant injection on the performance of an inverter-driven scroll compressor
Dutta 1996 International Compressor Engineering Conference, Paper 1112 A study on compression characteristic of wet vapor refrigerant
Int. J. Refrigeration Dutta 24 577 2001 10.1016/S0140-7007(00)00041-4 An investigation of the performance of a scroll compressor under liquid refrigerant injection
Appl. Therm. Eng. Feng 29 2942 2009 10.1016/j.applthermaleng.2009.03.001 Study on performance of a heat pump water heater using suction stream liquid injection
Int. J. Refrigeration Feng 32 509 2009 10.1016/j.ijrefrig.2008.06.012 Investigation of the heat pump water heater using economizer vapor injection system and mixture of R22/R600a
Energy Build. Guoyuan 40 697 2008 10.1016/j.enbuild.2007.05.003 Experimental study of a heat pump system with flash-tank coupled with scroll compressor
Int. J. Refrigeration Guoyuan 26 12 2003 10.1016/S0140-7007(02)00083-X Experimental investigation of air source heat pump for cold regions
ISO 13256-2 1998 Water Source Heat Pumps-Testing and Rating for Performance-Part 2: Water to Water and Brine to Water Heat Pumps
JARN 49 2011 World Air Conditioner Market: the 2010 Overview
Int. J. Refrigeration Kang 31 883 2008 10.1016/j.ijrefrig.2007.10.002 Effects of liquid injection on the performance of a refrigeration system with an accumulator heat exchanger
HVAC R Res. Liu 1 2 99 1995 10.1080/10789669.1995.10391312 A mathematical model for simulating liquid and vapor two-phase compression process and investigating slugging problem in compressors
Pham 2262 2012 International Refrigeration and Air Conditioning Conference, 16-17 R32 and HFOs as low GWP refrigerants for air conditioning
Stoecker 1958 Refrigeration and Air-conditioning
Int. J. Refrigeration Wang 32 1442 2009 10.1016/j.ijrefrig.2009.03.004 Two-stage heat pump system with vapor injected scroll compressor using R410A as a refrigerant
Int. J. Refrigeration Wang 32 1544 2009 10.1016/j.ijrefrig.2009.06.008 Optimization of refrigeration system with gas-injected scroll compressor
Int. J. Refrigeration Wang 30 179 2007 10.1016/j.ijrefrig.2006.04.007 Design of experimental bench and internal pressure measurement of scroll compressor with refrigerant injection
Int. J. Energy Res. Wang 30 835 2006 10.1002/er.1185 Investigation of the effects of vapour quality and oil concentration on performance of a swash plate compressor
Int. J. Refrigeration Winandy 25 1143 2002 10.1016/S0140-7007(02)00003-8 Scroll compressors using gas and liquid injection: experimental analysis and modelling