최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기Building and environment, v.135, 2018년, pp.352 - 364
Jain, Sneha (Corresponding author.) , Garg, Vishal
Abstract Automated shading and integrated lighting control systems are being used in buildings for electrical energy savings and improve occupant's comfort. These systems facilitate effective utilization of useful daylight in interior spaces that benefit an occupant's health, well-being, and produc...
Boyce 2003 The Benefits of Daylight through Windows, Troy, New York
ASHRAE J. Heschong 44 65 2002 Daylighting and human performance
Build. Environ. O'Brien 60 319 2013 10.1016/j.buildenv.2012.10.003 Manually-operated window shade patterns in office buildings: a critical review
Build. Environ. Kim 44 1517 2009 10.1016/j.buildenv.2008.08.006 An experimental study on the environmental performance of the automated blind in summer
Build. Environ. Zhang 54 137 2012 10.1016/j.buildenv.2012.02.016 Factors influencing occupants' blind-control behaviour in a naturally ventilated office building
Build. Environ. Gunay 113 185 2017 10.1016/j.buildenv.2016.08.027 Development and implementation of an adaptive lighting and blinds control algorithm
Sol. Energy Galasiu 76 523 2004 10.1016/j.solener.2003.12.007 Impact of window blinds on daylight-linked dimming and automatic on/off lighting controls
Sol. Energy Yang 84 1513 2010 10.1016/j.solener.2010.05.014 Economic analysis of the daylight-linked lighting control system in office buildings
Lee 1998 Proc. Therm. Perform. Exter. Envel. Build Integrated performance of an automated Venetian blind/electric lighting system in a full-scale private office
Mukherjee 9 2010 2010 ACEEE Summer Study Energy Effic. Build Closed loop integrated lighting and daylighting control for low energy buildings
Build. Environ. Shen 78 155 2014 10.1016/j.buildenv.2014.04.028 Energy and visual comfort analysis of lighting and daylight control strategies
Tzempelikos 81 369 2007 The impact of shading design and control on building cooling and lighting demand
Energy Build. Bourgeois 38 814 2006 10.1016/j.enbuild.2006.03.002 Adding advanced behavioural models in whole building energy simulation: a study on the total energy impact of manual and automated lighting control
Light. Res. Technol. Reinhart 35 243 2003 10.1191/1365782803li064oa Monitoring manual control of electric lighting and blinds
Renew. Sustain. Energy Rev. ul Haq 33 268 2014 10.1016/j.rser.2014.01.090 A review on lighting control technologies in commercial buildings, their performance and affecting factors
Build. Environ. Bellia 106 301 2016 10.1016/j.buildenv.2016.06.040 Why are daylight-linked controls (DLCs) not so spread? A literature review
Energy Build. Motamed 149 58 2017 10.1016/j.enbuild.2017.05.017 On-site monitoring and subjective comfort assessment of a sun shadings and electric lighting controller based on novel High Dynamic Range vision sensors
Doulos 125 2005 Proc. Eur. Conf. Dyn. Anal. Simul. Test. Appl. To Energy Environ. Perform. Build. (DYNASTEE), Athens, Greece A critical review of simulation techniques for daylight responsive systems
Build. Environ. Park 46 747 2011 10.1016/j.buildenv.2010.10.007 Performance of integrated systems of automated roller shade systems and daylight responsive dimming systems
Energy Build. Caicedo 73 105 2014 10.1016/j.enbuild.2014.01.022 Daylight-adaptive lighting control using light sensor calibration prior-information
Energy Build. Peruffo 97 13 2015 10.1016/j.enbuild.2015.03.049 Lighting control with distributed wireless sensing and actuation for daylight and occupancy adaptation
Lee 2017 Demonstration of Energy Efficient Retrofits for Lighting and Daylighting in New York City Office Buildings
Energy Build. Fernandes 68 498 2014 10.1016/j.enbuild.2013.10.009 Monitored lighting energy savings from dimmable lighting controls in the New York Times Headquarters Building
Energy Build. Delvaeye 127 969 2016 10.1016/j.enbuild.2016.06.033 Analysis of energy savings of three daylight control systems in a school building by means of monitoring
Mahdavi 693 2005 Ninth Int. IBPSA Conf., Montreal, Canada Elements of a simulation-assisted daylight-responsive illumination systems control in buildings
Mahdavi vol. 2007 1175 2007 Incorporating simulation into building systems control logic
Humann 1740 2017 Build. Simul Using HDR sky luminance maps to improve accuracy of virtual work plane illuminance sensors
Mahdavi 2007 Proc. Clima 2007 WellBeing Indoors An integrated model-based approach to building systems operation
Build. Environ. Hu 46 786 2011 10.1016/j.buildenv.2010.10.013 Illuminance-based slat angle selection model for automated control of split blinds
Sol. Energy ongradac 86 2762 2012 10.1016/j.solener.2012.06.016 Algorithm for blinds control based on the optimization of blind tilt angle using a genetic algorithm and fuzzy logic
Ahmad 2017 Build. Simul. 2017 Random forests and artificial neural network for predicting daylight illuminance and energy consumption
Walger 779 2017 Build. Simul. 2017 The potential of artificial neural networks to model daylight harvesting in buildings located in different climate zones
Build. Simul Colaco 1 279 2008 10.1007/s12273-008-8126-8 Prospective techniques of effective daylight harvesting in commercial buildings by employing window glazing, dynamic shading devices and dimming control-a literature review
Gentile 632 2015 2015 IEEE 15th Int. Conf. Environ. Electr. Eng Daylight harvesting control systems design recommendations based on a literature review
Build. Environ. de Bakker 112 308 2017 10.1016/j.buildenv.2016.11.042 Occupancy-based lighting control in open-plan office spaces: a state-of-the-art review
Energy Build. Dubois 43 2572 2011 10.1016/j.enbuild.2011.07.001 Energy saving potential and strategies for electric lighting in future North European, low energy office buildings: a literature review
Energy Build. Lowry 133 489 2016 10.1016/j.enbuild.2016.10.003 Energy saving claims for lighting controls in commercial buildings
Renew. Sustain. Energy Rev. Yu 52 494 2015 10.1016/j.rser.2015.07.142 Daylight availability assessment and its potential energy saving estimation -A literature review
LEUKOS J. Illum. Eng. Soc. North Am. Williams 8 161 2012 10.1582/LEUKOS.2012.08.03.001 Lighting controls in commercial buildings
Build. Simul Mahdavi 1 25 2008 10.1007/s12273-008-8101-4 Predictive simulation-based lighting and shading systems control in buildings
1163 2005 Ninth Int. IBPSA Conf., Montreal, Canada Sky luminance mapping for computational daylight modeling
Mahdavi 6 2006 23rd Conf. Passiv. Low Energy Archit., Geneva, Switzerland An energy-efficient simulation-assisted lighting control system for buildings
vol. 2007 1205 2007 Calibrated sky luminance maps for advanced daylight simulation applications
Inanici 679 2016 PLEA 2016 Los Angeles 32nd Int. Conf. Passiv. Low Energy Archit., Los Angeles Robust sky modelling practices in daylighting simulations
Build. Environ. Inanici 113 220 2017 10.1016/j.buildenv.2016.09.022 An investigation of the daylighting simulation techniques and sky modeling practices for occupant centric evaluations
Illum. Eng. Soc. North Am. Inanici 7 69 2010 Evaluation of high dynamic range image based sky models in lighting simulation, LEUKOS J
Build. Environ. Jones 113 131 2017 10.1016/j.buildenv.2016.08.023 Experimental validation of ray tracing as a means of image-based visual discomfort prediction
Wu 2695 2017 Build. Simul., San Francisco, CA, USA An embedded system for quasi real-time lighting computation based on sky monitoring
Energy Procedia Borowczyski 78 1769 2015 10.1016/j.egypro.2015.11.301 Application of sky digital images for controlling of louver system
Stumpfel 145 2004 ACM Int. Conf. Comput. Graph. Virtual Real. Vis. Africa, New York Direct HDR capture of the sun and sky
Adv. Build. Energy Res. Jacobs 1 177 2007 10.1080/17512549.2007.9687274 High dynamic range imaging and its application in building research
Comput. Graph. Forum Gryaditskya 33 61 2014 10.1111/cgf.12474 Sky based light metering for high dynamic range images
Indoor Built Environ. Li 18 477 2009 10.1177/1420326X09337042 Evaluation of a simple method for determining the vertical daylight factor against full-scale measured data
Energy Li 30 1649 2005 10.1016/j.energy.2004.04.038 Predicting daylight illuminance on inclined surfaces using sky luminance data
Energy Convers. Manag. Chaiwiwatworakul 50 2927 2009 10.1016/j.enconman.2009.07.008 Application of automated blind for daylighting in tropical region
Hu vol. 2012 2012 Incorporating sky luminance data measured by EKO scanner with a scanning sky simulator for predicting daylight quantity in buildings
Build. Environ. Igawa 36 763 2001 10.1016/S0360-1323(00)00062-7 All Sky Model as a standard sky for the simulation of daylit environment
J. Illum. Eng. Soc. DiBartolomeo 26 146 1997 10.1080/00994480.1997.10748175 Developing a dynamic envelope/lighting control system with field measurements
Energy Build. Yun 84 70 2014 10.1016/j.enbuild.2014.07.040 The influence of shading control strategies on the visual comfort and energy demand of office buildings
J. Illum. Eng. Soc. Lee 28 3 1999 10.1080/00994480.1999.10748247 The effect of Venetian blinds on daylight photoelectric control performance
Light. Res. Technol. Colaco 44 459 2012 10.1177/1477153512445713 Integrated design and real-time implementation of an adaptive, predictive light controller
Build. Environ. Iwata 113 232 2017 10.1016/j.buildenv.2016.08.034 Automated blind control based on glare prevention with dimmable light in open-plan offices
Energy Procedia Wu 122 649 2017 10.1016/j.egypro.2017.07.364 Characterization of a quasi-real-time lighting computing system based on HDR imaging
Tzempelikos 1065 2007 2nd PALENC Conf. 28th AIVC Conf. Build. Low Energy Cool. Adv. Vent. Technol. 21st Century, Crete Island, Greece Daylight and luminaire control in a perimeter zone using an automated Venetian blind
AIJ J. Technol. Des Taniguchi 22 159 2016 10.3130/aijt.22.159 Comparison study on effect of slat shape and optical property of gradation blind on reduction of electric consumption for ambient lighting
Ineichen 1993 Characterisation and Comparison of Two Sky Scanners
Energy Build. Al Touma 151 263 2017 10.1016/j.enbuild.2017.06.058 Shading and day-lighting controls energy savings in offices with fully-Glazed facades in hot climates
US Department of Energy 2004 EnergyPlus Engineering Reference: the Reference to EnergyPlus Calculations
Appl. Ergon. Hopkinson 3 206 1972 10.1016/0003-6870(72)90102-0 Glare from daylighting in buildings
Taniguchi 3 2012 Exp. Light 2012 Int. Conf., Eindhoven, the Netherlands Blind control method based on prevention of discomfort glare taking account of building conditions
Sol. Energy Chan 86 3109 2012 10.1016/j.solener.2012.07.021 A hybrid ray-tracing and radiosity method for calculating radiation transport and illuminance distribution in spaces with Venetian blinds
Sol. Energy Chan 98 241 2013 10.1016/j.solener.2013.10.005 Efficient Venetian blind control strategies considering daylight utilization and glare protection
Energy Build. Wienold 38 743 2006 10.1016/j.enbuild.2006.03.017 Evaluation methods and development of a new glare prediction model for daylight environments with the use of CCD cameras
Wienold vol. 2009 944 2009 Dynamic daylight glare evaluation
Light. Res. Technol. Jakubiec 44 149 2012 10.1177/1477153511420097 The “adaptive zone” - a concept for assessing discomfort glare throughout daylit spaces
Build. Environ. Konstantzos 87 244 2015 10.1016/j.buildenv.2015.02.007 Experimental and simulation analysis of daylight glare probability in offices with dynamic window shades
Atzeri 1576 2017 Proc. 15th IBPSA Conf., San Francisco, CA, USA Comparison of different glare indices through metrics for long term and zonal visual comfort assessment
Buildings Costanzo 7 41 2017 10.3390/buildings7020041 A review of daylighting strategies in schools: state of the art and expected future trends
Chang 849 2001 Seventh Int. IBPSA Conf., Rio de Janeiro, Brazil A hybrid system for daylight-responsive lighting control
Sol. Energy Reinhart 77 15 2004 10.1016/j.solener.2004.04.003 Lightswitch-2002: a model for manual and automated control of electric lighting and blinds
Renew. Sustain. Energy Rev. Carlucci 47 1016 2015 10.1016/j.rser.2015.03.062 A review of indices for assessing visual comfort with a view to their use in optimization processes to support building integrated design
Scientometrics van Eck 84 523 2010 10.1007/s11192-009-0146-3 Software survey: VOSviewer, a computer program for bibliometric mapping
Sol. Energy Littlefair 53 315 1994 10.1016/0038-092X(94)90034-5 A comparison of sky luminance models with measured data from Garston, United Kingdom
Architect. Sci. Rev. Li 46 61 2003 10.1080/00038628.2003.9696965 A study of 15 sky luminance patterns against Hong Kong data
Sol. Energy Perez 50 235 1993 10.1016/0038-092X(93)90017-I All-weather model for sky luminance distribution-preliminary configuration and validation
K. R, P. R, D. S 359 1997 Proc. LUX Eur. Conf., Amsterdam A new generation of sky standards
Sensors Lee 9 3875 2009 10.3390/s90503875 Sun tracking systems: a review
Sol. Energy Zhang 86 860 2012 10.1016/j.solener.2011.12.015 An open-loop Venetian blind control to avoid direct sunlight and enhance daylight utilization
Energy Build. Kim 39 935 2007 10.1016/j.enbuild.2006.10.009 The impact of daylight fluctuation on a daylight dimming control system in a small office
IEEE Comput. Graph. Appl. Debevec 22 26 2002 10.1109/38.988744 Image-based lighting
Ward 459 1994 Proc. 21st Annu. Conf. Comput. Graph. Interact. Tech. - SIGGRAPH ’94 The RADIANCE lighting simulation and rendering system
Ward 2005 Photosphere
Kenny 2006 Proc. EuroSun 2006 Conf Whole-sky luminance maps from calibrated digital photography
Roy 1998 Sky Modelling from Digital Imagery, Sydney
J. Sol. Energy Eng. Muneer 124 34 2002 10.1115/1.1435647 A new method for correcting shadow band diffuse irradiance data
Duffie 2013 Solar Engineering of Thermal Processes
Light. Res. Technol. Tregenza 15 65 1983 10.1177/096032718301500201 Daylight coefficients
B. W 1983 Daylighting Coefficient of Utilization Tables
Murdoch 2003 Illumination Engineering: from Edison's Lamp to the Laser
Willmott 1997 An Empirical Comparison of Radiosity Algorithms
2011 The Lighting Handbook
CIE Technical Committee 1995 CIE 117-1995 Discomfort Glare in Interior Lighting, Vienna
Light. Res. Technol. Chauvel 14 31 1982 10.1177/096032718201400103 Glare from windows: current views of the problem
Wienold vol. 2007 1197 2007 Dynamic simulation of blind control strategies for visual comfort and energy balance analysis
Sol. Energy Chan 98 241 2013 10.1016/j.solener.2013.10.005 Efficient Venetian blind control strategies considering daylight utilization and glare protection
Jones 1229 2015 14th Int. Conf. Int. Build. Perform. Simul. Assoc Validation of GPU lighting simulation in naturally and artificially lit spaces
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
※ AI-Helper는 부적절한 답변을 할 수 있습니다.