NTIS 바로가기IEEE transactions on medical imaging, v.37 no.7, 2018년, pp.1587 - 1596
Kim, Seungeon (School of Electrical Engineering, Korea Advanced Institute of Science and Technology, Daejeon, South Korea) , Chang, Yongjin (School of Electrical Engineering, Korea Advanced Institute of Science and Technology, Daejeon, South Korea) , Ra, Jong Beom (School of Electrical Engineering, Korea Advanced Institute of Science and Technology, Daejeon, South Korea)
Cardiac X-ray computed tomography (CT) imaging is still challenging due to the cardiac motion during CT scanning, which leads to the presence of motion artifacts in the reconstructed image. In response, many cardiac X-ray CT imaging algorithms have been proposed, based on motion estimation (ME) and ...
Baumann, Stefan, Wang, Rui, Schoepf, U. Joseph, Steinberg, Daniel H., Spearman, James V., Bayer II, Richard R., Hamm, Christian W., Renker, Matthias. Coronary CT angiography-derived fractional flow reserve correlated with invasive fractional flow reserve measurements - initial experience with a novel physician-driven algorithm. European radiology, vol.25, no.4, 1201-1207.
Segars, W. P., Sturgeon, G., Mendonca, S., Grimes, Jason, Tsui, B. M. W.. 4D XCAT phantom for multimodality imaging research. Medical physics, vol.37, no.9, 4902-4915.
De Pierro, A.R.. A modified expectation maximization algorithm for penalized likelihood estimation in emission tomography. IEEE transactions on medical imaging, vol.14, no.1, 132-137.
Sotiras, A., Davatzikos, C., Paragios, N.. Deformable Medical Image Registration: A Survey. IEEE transactions on medical imaging, vol.32, no.7, 1153-1190.
Proc 4th Int Conf Image Formation X-Ray Comput Tomogr Reduction of cone angle effect in cardiac motion correction based on partial angle reconstructed images in CT kim 2016 439
Tang, Jie, Hsieh, Jiang, Chen, Guang‐Hong. Temporal resolution improvement in cardiac CT using PICCS (TRI‐PICCS): Performance studies. Medical physics, vol.37, no.8, 4377-4388.
Proc 2nd Int Conf Image Formation X-Ray Comput Tomogr An analysis of motion artifacts in CT and implications for motion compensation pack 2012 322
Crum, W. R., Camara, O., Hawkes, D. J.. Methods for Inverting Dense Displacement Fields: Evaluation in Brain Image Registration. Lecture notes in computer science, vol.4791, 900-907.
Erdogan, H., Fessler, J.A.. Monotonic algorithms for transmission tomography. IEEE transactions on medical imaging, vol.18, no.9, 801-814.
Flohr, T. G., Bruder, H., Stierstorfer, K., Petersilka, M., Schmidt, B., McCollough, C. H.. Image reconstruction and image quality evaluation for a dual source CT scanner. Medical physics, vol.35, no.12, 5882-5897.
Wang, R., Baumann, S., Schoepf, U.J., Meinel, F.G., Rier, J.D., Morris, J.Z., Mollmann, H., Hamm, C.W., Steinberg, D.H., Renker, M.. Comparison of quantitative stenosis characteristics at routine coronary computed tomography angiography with invasive fractional flow reserve for assessing lesion-specific ischemia. Journal of cardiovascular computed tomography, vol.9, no.6, 546-552.
Grangeat, Pierre, Koenig, Anne, Rodet, Thomas, Bonnet, Stéphane. Theoretical framework for a dynamic cone-beam reconstruction algorithm based on a dynamic particle model. Physics in medicine & biology, vol.47, no.15, 2611-2625.
van Stevendaal, U., von Berg, J., Lorenz, C., Grass, M.. A motion-compensated scheme for helical cone-beam reconstruction in cardiac CT angiography : Motion-compensated reconstruction in cardiac CT. Medical physics, vol.35, no.7, 3239-3251.
Isola, Alfonso A., Grass, Michael, Niessen, Wiro J.. Fully automatic nonrigid registration‐based local motion estimation for motion‐corrected iterative cardiac CT reconstruction. Medical physics, vol.37, no.3, 1093-1109.
Bhagalia, Roshni, Pack, Jed D., Miller, James V., Iatrou, Maria. Nonrigid registration-based coronary artery motion correction for cardiac computed tomography : Non-rigid registration-based coronary artery motion correction for CT. Medical physics, vol.39, no.7, 4245-4254.
Tang, Qiulin, Cammin, Jochen, Srivastava, Somesh, Taguchi, Katsuyuki. A fully four-dimensional, iterative motion estimation and compensation method for cardiac CT : Motion estimation and compensation method for cardiac CT. Medical physics, vol.39, no.7, 4291-4305.
Method for computed tomography motion estimation and compensation pack 2012
Rohkohl, Christopher, Bruder, Herbert, Stierstorfer, Karl, Flohr, Thomas. Improving best‐phase image quality in cardiac CT by motion correction with MAM optimization. Medical physics, vol.40, no.3, 031901-.
Proc 1995 Intl Meeting on Fully 3D Image Reconstruction in Radiology and Nucl Med Four-dimensional projection-based motion estimation and compensation for cardiac X-ray CT tang 2013 46
Kim, Seungeon, Chang, Yongjin, Ra, Jong Beom. Cardiac motion correction based on partial angle reconstructed images in x‐ray CT. Medical physics, vol.42, no.5, 2560-2571.
Grass, M, Manzke, R, Nielsen, T, Koken, P, Proksa, R, Natanzon, M, Shechter, G. Helical cardiac cone beam reconstruction using retrospective ECG gating. Physics in medicine & biology, vol.48, no.18, 3069-3084.
Schafer, D., Borgert, J., Rasche, V., Grass, M.. Motion-compensated and gated cone beam filtered back-projection for 3-D rotational X-ray angiography. IEEE transactions on medical imaging, vol.25, no.7, 898-906.
Kachelriess, M., Ulzheimer, S., Kalender, W.A.. ECG-correlated imaging of the heart with subsecond multislice spiral CT. IEEE transactions on medical imaging, vol.19, no.9, 888-901.
Nielsen, T., Manzke, R., Proksa, R., Grass, M.. Cardiac cone‐beam CT volume reconstruction using ART. Medical physics, vol.32, no.4, 851-860.
Computed Tomography Principles Design Artifacts and Recent Advances hsieh 2009
Stierstorfer, Karl, Rauscher, Annabella, Boese, Jan, Bruder, Herbert, Schaller, Stefan, Flohr, Thomas. Weighted FBP—a simple approximate 3D FBP algorithm for multislice spiral CT with good dose usage for arbitrary pitch. Physics in medicine & biology, vol.49, no.11, 2209-2218.
Tang, Xiangyang, Hsieh, Jiang, Nilsen, Roy A, Dutta, Sandeep, Samsonov, Dmitry, Hagiwara, Akira. A three-dimensional-weighted cone beam filtered backprojection (CB-FBP) algorithm for image reconstruction in volumetric CT—helical scanning. Physics in medicine & biology, vol.51, no.4, 855-874.
Koken, P, Grass, M. Aperture weighted cardiac reconstruction for cone-beam CT. Physics in medicine & biology, vol.51, no.14, 3433-3448.
Kachelrieß, Marc, Ulzheimer, Stefan, Kalender, Willi A.. ECG‐correlated image reconstruction from subsecond multi‐slice spiral CT scans of the heart. Medical physics, vol.27, no.8, 1881-1902.
Husmann, Lars, Leschka, Sebastian, Desbiolles, Lotus, Schepis, Tiziano, Gaemperli, Oliver, Seifert, Burkhardt, Cattin, Philippe, Frauenfelder, Thomas, Flohr, Thomas G., Marincek, Borut, Kaufmann, Philipp A., Alkadhi, Hatem. Coronary Artery Motion and Cardiac Phases: Dependency on Heart Rate-Implications for CT Image Reconstruction. Radiology, vol.245, no.2, 567-576.
Halliburton, S., Arbab-Zadeh, A., Dey, D., Einstein, A.J., Gentry, R., George, R.T., Gerber, T., Mahesh, M., Weigold, Wm.G.. State-of-the-art in CT hardware and scan modes for cardiovascular CT. Journal of cardiovascular computed tomography, vol.6, no.3, 154-163.
Hahn, Juliane, Bruder, Herbert, Rohkohl, Christopher, Allmendinger, Thomas, Stierstorfer, Karl, Flohr, Thomas, Kachelrieß, Marc. Motion compensation in the region of the coronary arteries based on partial angle reconstructions from short‐scan CT data. Medical physics, vol.44, no.11, 5795-5813.
Achenbach, Stephan, Marwan, Mohamed, Schepis, Tiziano, Pflederer, Tobias, Bruder, Herbert, Allmendinger, Thomas, Petersilka, Martin, Anders, Katharina, Lell, Michael, Kuettner, Axel, Ropers, Dieter, Daniel, Werner G., Flohr, Thomas. High-pitch spiral acquisition: A new scan mode for coronary CT angiography. Journal of cardiovascular computed tomography, vol.3, no.2, 117-121.
Seungeon Kim, Yongjin Chang, Jong Beom Ra. Cardiac Image Reconstruction via Nonlinear Motion Correction Based on Partial Angle Reconstructed Images. IEEE transactions on medical imaging, vol.36, no.5, 1151-1161.
Chen, Marcus Y., Shanbhag, Sujata M., Arai, Andrew E.. Submillisievert Median Radiation Dose for Coronary Angiography with a Second-Generation 320–Detector Row CT Scanner in 107 Consecutive Patients. Radiology, vol.267, no.1, 76-85.
Liu, Lili, Yang, Wenjie, Nagahara, Yasuomi, Li, Yingguang, Lamooki, Saeb R., Muramatsu, Takashi, Kitslaar, Pieter, Sarai, Masayoshi, Ozaki, Yukio, Barlis, Peter, Yan, Fuhua, Reiber, Johan H. C., Tu, Shengxian. The impact of image resolution on computation of fractional flow reserve: coronary computed tomography angiography versus 3-dimensional quantitative coronary angiography. The international journal of cardiovascular imaging, vol.32, no.3, 513-523.
Liang, J., Wang, H., Xu, L., Yang, L., Dong, L., Fan, Z., Wang, R., Sun, Z.. Diagnostic performance of 256-row detector coronary CT angiography in patients with high heart rates within a single cardiac cycle: a preliminary study. Clinical radiology, vol.72, no.8, 694.e7-694.e14.
Hedgire, S., Ghoshhajra, B., Kalra, M.. Dose optimization in cardiac CT. Physica medica : European journal of medical physics, vol.41, 97-103.
Walker, Jonathan R., Abadi, Sobhi, Solomonica, Amir, Mutlak, Diab, Aronson, Doron, Agmon, Yoram, Lessick, Jonathan. Left-sided cardiac chamber evaluation using single-phase mid-diastolic coronary computed tomography angiography: derivation of normal values and comparison with conventional end-diastolic and end-systolic phases. European radiology, vol.26, no.10, 3626-3634.
해당 논문의 주제분야에서 활용도가 높은 상위 5개 콘텐츠를 보여줍니다.
더보기 버튼을 클릭하시면 더 많은 관련자료를 살펴볼 수 있습니다.
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
※ AI-Helper는 부적절한 답변을 할 수 있습니다.