최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기大韓齒科保存學會誌 = Journal of Korean Academy of Operative Dentistry, v.30 no.2, 2005년, pp.121 - 127
양원경 (서울 아산병원 치과보존과) , 라윤식 (서울 아산병원 치과보존과) , 이영규 (서울 아산병원 치주과) , 손호현 (서울대학교 치과대학 치과보존학교실) , 김미리 (서울 아산병원 치과보존과)
A variety files made of stainless steel (S-S) or nickel-titanium (Ni-Ti) are used during endodontic treatment. The purpose of tt)is study was to evaluate the corrosion susceptibility of S-S and Ni-Ti endodontic files. Three brands of files were used for this study:
Bahcall JK, Barss JT. Understanding and evaluating the endodontic file. Gen Dent 11-12:690-692, 2000
Walia H, Brantley WA, Gerstein H. An initial investigation of the bending and torsional properties of nitinol root canal files. J Endod 14:346-351, 1998
Assad M, Chernyshov AV, Jarzem P, Leroux MA, Coillard C, Charette S, Rivard CH. Porous titanium-nickel for Intervertebral fusion in a sheep model: part 2. Surface analysis and nickel release assessment. J Biomed Mater Res Part B; Applied Biomat 64B:121-129, 2003
Mize SB, Pruett JP, Clement DJ, Carnes DL. Effect to sterilization on cyclic fatigue of rotary nickel-titanium endodontic instruments. J Endod 24:843-847, 1998
Filho IB, Esberard RM, Leonardo RT, Del Rio CE. Microsopic evaluation of three endodontic files pre- and postinstrumentation. J Endod 24:461-464, 1998
Stokes OW, Di Fiore PM, Barss JT, Koerber A, Gilbert JL, Lautenschlager EP. Corrosion in stainless-steel and nickel titanium files. J Endod 25:17-20, 1999
Neal RG, Craig RG, Powers JM. Effects of sterilization and irrigants on the cutting ability of stainless steel files. J Endod 9:93-96, 1983
Haikel Y, Serfaty R, Speisser WJM, Alleman C. Cutting efficiency of nickel-titanium endodontic instruments and the effect of sodium hypochlorite treatment. J Endod 24:736-739, 1998
Busslinger A, Sener B, Barbakow F. Effects of sodium hypochlorite on nickel-titanium Lightspeed instruments. Int Endod J 31:290-294, 1998
Haikel Y, Serfaty R, Speisser WJM, Alleman C. Mechanical properties of nickel-titanium endodontic instruments and the effect of sodium hypochlorite treatment. J Endod 24:731-735, 1998
Sakar NK, Redmond W, Schwaninger B, Goldberg AJ. The chloride corrosion behaviour of four ortbodontic wires. J Oral Rehabil 10:121-128, 1983
Hurtt CA, Rossman LE. The sterilization of endodontic hand files. J Endod 22:321-322, 1996
Charles et al. Sterilization or disinfection of dental instruments In: Accepted dental therapeutics 40th. American Dental Association, Chicago, IL, p134-150, 1984
Willet NP, White RR, Rosen S. Disinfection and sterilization In: Essential Dental Mocrobiology. Appletin & Lange, East Norwalk, CO, p58-61, 1991
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
※ AI-Helper는 부적절한 답변을 할 수 있습니다.