최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기대한치주과학회지 = The journal of Korean academy of periodontology, v.35 no.3, 2005년, pp.777 - 788
백승재 (강릉대학교 치과대학 치주과학 교실) , 이재관 (강릉대학교 치과대학 치주과학 교실) , 박찬진 (강릉대학교 치과대학 치과보철학 교실)
The primary stability of implants is an important factor to predict the osseointegration. Recently, the resonance frequency analysis has been used to measure the primary stability. It is an objective method to monitor the stability of implants during healing phase. This study is to validate the diff...
Jemt T, Leckholm U, Adell R. Osseointegrated implants in the treatment of partially edentulous patients: a preliminary study on 876 consecutively placed fixtures. Int J Oral Maxillofac Implants 1989:4:211-217
Jemt T, Leckholm U. Oral implant treatment in posterior partially edentulous jaws: a 5-year follow-up report. Int J Oral Maxillofac Implants 1993:8:635-640
Leckholm U, Gunne J, Henry P, Higuchi K, Linden U, Bergstrom C, van Steenberghe D. Survial of the Branemark implant in partially edentulous jaw: a 10-year prospective multicenter study. Int J Oral Maxillofac Implants 1999: 14: 639-45
Noack N, Willer J, Hoffmann J. Long-term results after placement of dental implants: longitudinal study of 1964 implants over 16 year. Int J Oral Maxillofac Implants 1999: 14:748-755
Albrektsson T, Zarb GA Worthington P, Eriksson RA. The long-term efficacy of currently used dental implants. A review and proposed criteria of success. Int J Oral Maxillofac Implants 1986: 1: 11-25
Albrektsson T, Branemark PI, Hasson HA, Lindstrom J. Titanium implant. Requirements for ensuring a long-lasting direct bone anchorage in man. Acta Orthopaedica Scandinavica 1981:52: 155-170
Albrektsson T, Dahl E, Enbom L, Engevall S, Engquist B, Eriksson AR, Feldmann G, Freiberg N, Glantz PO, Kjellman O, et al. Osseointegrated oral implants. A Swedish multicenter study of 8139 Consecutively inserted Nobelpharma implants. J Periodontol. 1988 May: 59(5) : 287-96
Jaffin RA, Berman CL. The excessive loss of Branemark fixtures in type IV bone: a 5-year analysis. J Periodontol. 1991 Jan: 62(1) :2-4
Friberg B, Jempt T, Lekholm U. Early failures in 4,641 consecutively placed Branemark dental implants: a study from stage 1 surgery to the connection of completed prostheses. Int J Oral Maxillofac Implants. 1991 Summer: 6(2) : 142-6
Meredith N, Book K, Friberg B, Jemt T, Sennerby L. Resonance requency measurements of implant stability in vivo. A cross-sectioinal and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla. Clin Oral Impl Res 1997; 8:226-33
Schulte W, d'Hoedt B, Lukas D, Muhlbradt L, Scholz F, Bretschi J, Frey D, Gudat H, Konig M, Markl M, et al. Periotest-a new measurement process for periodontal function. Zahnarztl Mitt. 1983 Jun 1:73(11):1229-30, 1233-6, 1239-40. German
Tricio J, Laohapand P, van Steenberghe D, Quirynen M, Naert I. Mechanical state assessment of the implant-bone continuum: a better understanding of the Periotest method. Int J Oral Maxillofac Implants. 1995 Jan-Feb; 10(1) :43-9
Cauleir H, Naert I. Kalk W, Jansen JA. The relationship of some histologic parameters, radiographic evaluations, and Periotest measurements of oral implants: An experimental animal study. Int J Oral Maxillofac Implants. 1997;12:380-386
Van Steenberghe D, Tricio J, Naert I. Nys M. Damping chracteristics of bone-to-implant interaction. A clinical study with the $Periotest^{\circledR}$ device. Clin Oral Impl Res. 1995:6:31-39
Meredith N. Shagaldi F, Alleyne D, Sennerby L, Cawley P. The application of resonance frequency measurements to study the stability of titanium implants during healing in the rabbit tibia. Clin Oral Implants Res. 1997;8:234-43
Friberg B, Sennerby L, Linden B. Grondahl K, Lekholm U. Stability measurements of one-stage Branemark implants during healing in mandibles. A clinical resonance frequency analysis study. Int J Oral Maxillofac Surg. 1999;28:266-72
Rasmusson L. Stegersjo G. Kahnberg KE. Sennerby L. Implant stability measurements using resonance frequency analysis in the grafted maxilla: a cross-sectional pilot study. Clin Implant Dent Relat Res. 1999; 1: 70-4.
Meredith N, Alleyne D, Cawley P. Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis. Clin Oral Impl Res 1996:7:261-7
Meredith N. Assessment of implant stability as a prognositc determinant. Int J Prosthodont 1998; 11 : 491-501
Sennerby L. Meredith N. Resonance frequency analysis: measuring implant stability and osseointegration. Compendium 1998; 19(5): 493-502
Tonetti MS. Schmid J. Pathogenesis of implant failures. Periodontol 2000 1994; 4: 127-138
Adell R. Eriksson B. Lekholm U, Branemark PI. Jemt T. Long-term follow-up study of osseointegrated implants in the treatment of totally edentulous jaws. Int J Oral Maxillofac Implants 1990:5: 347-359
Jaffin RA, Berman CL. The excessive loss of Branemark fixtures in type IV bone: a 5-year analysis. J Periodontol. 1991: 62 :2-4
Summers RB. A new concept in maxillary implant surgery: the osteotome technique. Compendium. 1994: 15: 152-158
Summers RB. The osteotome technique: Part 2- The ridge expansion osteotomy(REO) procedure. Compendium. 1994: 15: 422-426
Summers RB. The osteotome technique: Part 3- Less invasive methods of elevating the sinus floor. Compendium. 1994; 15: 698-704
Summers RB. The osteotome technique: Part 4- Future site development. Compend Contin Educ Dent. 1995; 16: 1080-1092
Buchter A, Kleinheinz J, Wiesmann HP, Kersken J, Nienkemper M, Weyhrother H, Joos U, Meyer U. Biological and biomechanical evaluation of bone remodelling and implant stability after using an osteotome technique. Clin Oral Implants Res. 2005 Feb; 16(1) : 1-8
Nkenke E. Kloss F, Wiltfang J, Schultze-Mosgau S, Radespiel-Troger M, Loos K, Neukam FW. Histomorphometric and fluorescence microscopic analysis of bone remodelling after installation of implants using an osteotome technique. Clin Oral Implants Res. 2002 Dec:13(6):595-602
Glauser G, Naef Rm Scharer P. The osteotome technique-A different method of implant placement in the posterior maxilla. Implantologie 1998;2:103-120
Adell R, Lekhom U, Rockler B, Branemark PI. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg. 1981 Dec: 10(6):387-416
Johns RB, Jempt T, Heath :MR, Hutton JE, McKenna S. McNamara DC. van Steenberghe D, Taylor R, Watson RM, Herrmann I. A multicenter study of overdentures supported by Branemark implants. Int J Oral Maxillofac Implants. 1992 Winter:7(4):513-22
Jempt, Lekholm U. Implant treatment in edentulous maxillae: A 5-year follow-up report on patients with different degrees of jaw resorption. Int J Oral Maxillofac Implant 1995: 10:303-311
Bahat O. Treatment planning and placement on implants in the posterior maxillae: Report of 732 consecutive Nobelpharma implants. Int J Oral Maxillofac Implants 1993:8:151-161
Adell R, Lekholmm U, Rockler B, Branemark PI. A 15 year study of osseointegrated implants in the treatment of edentulous jaw. Int J Oral Maxillofac Implants 1981: 10: 387-416
Cochran DL, Schenk R, Lussi A, Higginbottom FL, Buser D. Bone response to unloaded and loaded titanium implants with a sandblasted and acid-etched surface: A histometric study in the canine mandible. J Biomed Mater Res 1998:40: 1-11
Cochran DL. A comparison of endosseous dental implant surfaces. J Periodontol. 1999 Dec:70(12):1523-39
Summers RB. Sinus floor elevation with osteotomes. J Esthet Dent. 1998: 10(3): 164-71
Horowitz RA. The use of osteotomes for sinus augmentation at the time of implant placement. Compend Contin Educ Dent. 1997 May: 18(5) :441-7
O'Sullivan D. Sennerby L. Meredith N. Measurements comparing the initial stability of five designs of dental implants: a human cadaver study. Clin Implant Dent Relat Res. 2000:2(2) :85-92.
O'Sullivan D. Sennerby L. Meredith N. Influence of implant taper on the primary and secondary stability of osseointegrated titanium implants. Clin Oral Implants Res. 2004 Aug: 15(4) :474-80
Glauser R, Sennerby L. Meredith N. Ree A, Lundgren A, Gottlow J. Hammerle CH. Resonance frequency analysis of implants subjected to immediate or early functional occlusal loading. Successful vs. failing implants. Clin Oral Implants Res. 2004 Aug:15(4):428-34
Huang HM, Chiu CL. Yeh CY. Lin CT. Lin LH. Lee SY. Early detection of implant healing process using resonance frequency analysis. Clin Oral Impl Res 2003: 14:437-43
Huang HM. Lee SY. Yeh CY. Lin CT. Resonance frequency assessment of dental implant stability with various bone qualities: a numerical approach. Clin Oral Impl Res 2002: 13: 65-74
Nedir R. Bischof M, Szmukler-Moncler S. Bernard JP. Samson J. Predicting osseointegration by means of implant primary stability. Clin Oral Implants Res. 2004 Oct: 15(5) :520-8
Sennerby L. Thomsen P. Ericson LE. A morphometric and biomechanic comparison of titanium implants inserted in rabbit cortical and cancellous bone. Int J Oral Maxillofac Implants. 1992 Spring: 7(1) :62-71
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
※ AI-Helper는 부적절한 답변을 할 수 있습니다.