최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기Journal of biomedical engineering research : the official journal of the Korean Society of Medical & Biological Engineering, v.30 no.3, 2009년, pp.213 - 220
이효기 (연세대학교 의공학과) , 황성재 (연세대학교 의공학과) , 조성필 (연세대학교 의공학과) , 이동률 (지방공사 원주의료원 재활치료센터) , 유승현 (연세대학교 물리치료학과) , 이경중 (연세대학교 의공학과) , 김영호 (연세대학교 의공학과) , 정하중 (전자부품연구원 지능형정보연구센터)
In this study, we have developed a novel step detection algorithm for gait evaluation of patients with hemiplegia based on trunk accelerometry device. For this, we have used a bandpass filter and a least square acceleration (LSA) filter which is characterized by emphasizing the peak or valley point ...
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
Korean Stroke Society, http://www.stroke.or.kr
G.V. Smith, K.H. Silver, A.P. Goldberg and R.F. Macko, "Taskoriented exercise improves hamstring strength and spastic reflexes in chronic stroke patients," Stroke, vol. 30, No. 10, pp.2112-2118, October 1999
H.S. Jørgensen, "The Copenhagen Stroke Study Experience," J Stroke Cerebrovasc Dis, vol. 6, No. 1, pp. 5-16, September 1996
S. Mulroy, J. Gronley, W. Weiss, C. Newsam and J. Perry, "Use of cluster analysis for gait pattern classification of patients in the early and late recovery phases following stroke," Gait Posture,vol. 18, No. 1, pp. 114-125, August 2003
W.Y. Wong, M.S. Wong and K.H. Lo, "Clinical applications of sensors for human posture and movement analysis: A review," Prosthet Orthot Int, vol. 31, No. 1, pp. 62-75, March 2007
M. Molley, J. Salazar-Torres, C. Kerr, B.C. McDowell and A.P. Cosqrove, "The effects of industry standard averaging and filtering techniques in kinematic gait analysis," Gait Posture, vol. 28, No. 4, pp. 559-562, November 2008
M.J. Mathie, A.C. Coster, N.H. Lovell and B.G. Celler, "Accelerometry: providing an integrated, practical method for long-term, ambulatory monitoring of human movement," Physiol Meas, vol. 25, No. 2, pp. R1-R20, April 2004
R. Moe-Nilssen, "A new method for evaluating motor control in gait under real-life environmental conditions. Part 1: The instrument,"Clin Biomech, vol. 13, No. 4-5, pp. 320-327, June 1998
R. Moe-Nilssen, "A new method for evaluating motor control in gait under real-life environmental conditions. Part 2: Gait analysis", Clin Biomech, vol. 13, No. 4-5, pp. 328-335, June 1998
M. Henriksen, H. Lund, R. Moe-Nilssen, H. Bliddal and B. Danneskiod-Samsøe, "Test-retest reliability of trunk accelerometric gait analysis," Gait Posture, vol. 19, No. 3, pp. 288-297, June 2004
W. Zijstra and A.L. Hof, "Assessment of spatio-temporal gait parameters from trunk accelerations during human walking," Gait Posture, vol. 18, No. 2, pp. 1-10, October 2003
W. Zijstra, "Assessment of spatio-temporal parameters during unconstrained walking," Eur J Appl Physiol, vol. 92, No. 1-2, pp. 39-44, June 2004
R. Moe-Nilssen, J.L. Helbostad, "Estimation of gait cycle characteristics by trunk accelerometry," J Biomech, vol. 37, No.1, pp. 121-126, January 2004
M.G. Frei, R.L. Davidchack and I. Osorio, "Least squares acceleration filtering for the estimation of signal derivatives and sharpness at extrema," IEEE Trans Biomed Eng, vol. 46, No. 8, pp. 971-977, August 1999
M.N. Nyan, F.E. Tay, K.H. Seah and Y.Y. Sitoh, "Classification of gait patterns in the time-frequency domain," J Biomech, vol. 39, No. 14, pp. 2647-2656, October 2006
S.H. Lee, Y.T. Lim and K.J. Lee, "A design of an algorithm for analysis of activity using 3-axis accelerometer," The Transactions of the Korean Institute of Electrical Engineers D, vol. 53,No. 5, pp. 361-367, 2004
J.Y. Lee, K.J. Lee, Y.H. Kim, S.H. Lee and S.W. Park, "Development of gait analysis algorithm for hemiplegic patients based on accelerometry," Journal of the Institute of Electronics Engineers of Korea SC, vol. 41, No. 4, pp. 55-62, 2004
M.K. Holden, K.M. Gill, M.R. Magliozzi, J. Nathan and L. Piehl-Baker, "Clinical gait assessment in the neurologically impaired. Reliability and meaningfulness," Physical Therapy, vol. 64, No. 1, pp. 35-40, 1984
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
Free Access. 출판사/학술단체 등이 허락한 무료 공개 사이트를 통해 자유로운 이용이 가능한 논문
※ AI-Helper는 부적절한 답변을 할 수 있습니다.