최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기韓國컴퓨터情報學會論文誌 = Journal of the Korea Society of Computer and Information, v.14 no.6, 2009년, pp.41 - 49
신기영 (성균관대학교 생명공학부) , 문정환 (성균관대학교 생명공학부)
In this paper, the multi-camera calibration algorithm for optical motion capture system is proposed. This algorithm performs 1st camera calibration using DLT(Direct linear transformation} method and 3-axis calibration frame with 7 optical markers. And 2nd calibration is performed by waving with a wa...
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
J. L. Garrido Castro, R. Medina-Carnicer, Alfonso Martinez Galisteo, "Design and evaluation of a new three-dimensional motion capture system based on video," Gait & Posture, Vol. 24, No. 1, pp. 126-129, August 2006.
S. Hashi, M. Toyoda, S. Yabukami, K. Ishiyama, Y. Okazaki, and K.I. Arai, "Wireless magnetic motion capture system for multi-marker detection," IEEE transactions on magnetics, Vol. 42, No. 10, pp. 3279-3281, October 2006.
T. Jan-Phillip and L. Jorn, "A mobile low-cost motion capture system based on accelerometers," Lecture notes in computer science, Vol. 4292, pp. 437-446, October 2006.
Inition, http://www.inition.co.uk
최태준, 유석호, 이동열, 이완복, "광학식 모션 캡쳐방식을 이용한 디지털 캐릭터 움직임," 한국콘텐츠학회논문지, 제 7권, 제 8호, 109-116쪽, 2007년 8월.
Vicon, http://www.vicon.com
Qualisys, http://www.eualisys.com
Optitrack, http://www.naturalpoint.com/optitrack
안정현, 설창환, 박은광, 원광연, "LAN기반 광학식 모션 캡처 시스템 개발," HCI2000 학술대회, 429-432쪽, 2000.
A. Kalahi, Mo. Hoviattalab, T. Rezaeian, M. Alizadeh, M. Bostan, H. Mokhtarzadeh, "Design of a marker-based human motion tracking system," Biomedical signal processing and control, Vol. 2, No. 1, pp.59-67, January 2007.
T. Pribanic, P. Strum and M. Cifrek, "Calibration of 3D kinematic systems using orthogonality constraints," Machine vision and applications, Vol. 18, No. 6, pp.367-381, November 2007.
Y. I. Abdel-Aziz & H. M. Karara, "Direct linear transformation from comparator coordinates into object space coordinates in close-range photogrammetry," Proceedings of the Symposium on close-range photogrammetry, Falls church, VA: American society of photogrammetry, pp.1-18, 1971.
O. D. Faugeras and G. Toscani, "Camera calibration for 3D computer vision," Proc. international workship on industrial applications of machine vision and machine intelligence, Silken, Japan, pp.240-247, 1987.
R. I. Hartley, "Estimation of relative camera positions for uncalibrated cameras," Lecture notes in computer science, vol. 588, pp. 579-587, May 1992.
J.S. Walton, "Close-range cine-photogrammetry: a generalized technique for quantifying gross human motion". Ph.D. Dissertation, Pennsylvania State University, University Park, 1981.
H. Hatze, "High-precision three-dimensional photogrammetric calibration and object space reconstruction using a modified DLT-approach," J. Biomech., Vol. 21, Issue 7, pp.533-538. 1988.
L. Quan and S. Hang, "Correction of the asymmetrical circular projection in DLT camera calibration," Congress on image and signal processing, Vol. 2, pp.344-348, May 2008.
T. Svoboda, D. Martinec and T. Paidla, "A convenient multicamera self-calibration for virtual environments," Presence: teleoperators and virtual environments, Vol. 14, No. 4, pp. 407-422, August 2005.
Z. Chuan, T. Dalong and G. Hogwei, "A high-precision calibration and optimization method for stereo vision system," 9th International conference on control, automation, robotics and vision, pp. 1-5, December 2006.
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
Free Access. 출판사/학술단체 등이 허락한 무료 공개 사이트를 통해 자유로운 이용이 가능한 논문
※ AI-Helper는 부적절한 답변을 할 수 있습니다.