NTIS 바로가기한국동력기계공학회지 = Journal of the korean society for power system engineering, v.14 no.2, 2010년, pp.34 - 39
백승문 (부경대학교 대학원) , 최준혁 (부경대학교 대학원) , 변종영 (부경대학교 대학원) , 문춘근 ((주) 대일) , 정석권 (부경대학교 냉동공조공학과) , 윤정인 (부경대학교 냉동공조공학과)
Recently, technical trend for machine tools is focused on enhancement of speed and accuracy. High speedy processing causes thermal and structural deformation of objects from the machine tools. Water cooler has to be applied to machine tools to reduce the thermal negative influence with accurate temp...
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
Beak, S. M. et al., 2009, "Characteristics of Temperature Control by Hot-gas Bypass Flow Rate on Industrial Water Cooler", The Korean Society of Marine Engineering, Vol. 33, No. 8, pp. 55-62.
Lee, S. W., Yeom, H. K., 2008, "Performance of thermal error controller to minimize thermal deformation of machine tools", Proceeding of Korean Society for Precision Engineering(spring), pp. 376-380.
Lee, S. W. and Lee, C. W., 2007, "Assessment capability of oil cooler with hot-gas", Proceeding of Korean Society for Precision Engineering, No. 6, pp. 459-460.
J. H. Choi et al., 2009, "Performance Characteristics of Cooler Controled Capacity Using Hot-gas Bypass", Int. Symp. on Convective Heat and Mass Transfer in Sustainable Energy, Vol. 2, pp. 502-505.
Yaqub. M, Zubair S. M., Jameel-ur-Rehman Khan, 2000, "Performance evaluation of hot-gas bypass capacity control scheme for refrigeration and air-conditioning systems", Energy, Vol. 25, pp. 543-561.
Yaqub. M, Zubair S. M., Jameel-ur-Rehman Khan, 2000, "Performance evaluation of hot-gas bypass capacity control scheme for refrigeration and air-conditioning systems", Energy, Vol. 25, pp. 543-561.
Byun J. Y. et al., 2009 "Precise Temperature Control of Oil Cooler with Hot-gas Bypass", The Korean Society for Power System Engineering, KSPSE The 2009 Spring Conference, pp. 141-146.
Byun J. Y., Jeong J. M., and Jeong S. K.. 2009 "Hot-gas bypass control by PI logic for precise temperature of oil coolers with an electronic expansion valve", ISAMPE 2009, pp. 272-276.