NTIS 바로가기한국농공학회논문집 = Journal of the Korean Society of Agricultural Engineers, v.57 no.3, 2015년, pp.9 - 19
홍세운 (Division M3-BIORES: Measure, Model & Manage Bioresponses, Department of Biosystems, KU Leuven (Katholieke Universiteit Leuven)) , 문애경 (IT convergence Technology Research Laboratory, Electronics and Telecommunications Research Institute) , 리송 (IT convergence Technology Research Laboratory, Electronics and Telecommunications Research Institute) , 이인복 (Department of Rural Systems Engineering & Research Institute for Agriculture and Life Sciences, College of Agriculture and Life Sciences, Seoul National University)
Internal air temperature of greenhouse is an important variable that can be influenced by the complex interaction between outside weather and greenhouse inside climate. This paper focuses on a data-based model approach to predict internal air temperature of the greenhouse. External air temperature, ...
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
핵심어 | 질문 | 논문에서 추출한 답변 |
---|---|---|
온실 내의 적정 미기상 환경을 효과적으로 유지하기 위해 중요한 것은? | 온실 내의 적정 미기상 환경을 효과적으로 유지하기 위해서는 온실의 미기상 환경을 사전에 예측하는 것이 중요하다(Bakker, 2006). 컴퓨터의 발달과 더불어 온실 내 미기상을 예측하기 위한 많은 연구들이 진행되어 왔다. | |
본 연구를 위해 선정된 대상 온실은? | 대상 온실은 국립원예특작과학원 시설원예연구소 (부산) 내에 설치되어 있는 유리온실이다. 온실은 3개의 동으로 이루어져 있으며, 이 중 한 동을 연구 대상으로 정하였다(Fig. | |
대상 온실의 온실은 몇개의 동으로 이루어져 있는가? | 대상 온실은 국립원예특작과학원 시설원예연구소 (부산) 내에 설치되어 있는 유리온실이다. 온실은 3개의 동으로 이루어져 있으며, 이 중 한 동을 연구 대상으로 정하였다(Fig. 1(a)). |
Bakker, J.C., 2006. Model application for energy efficient greenhouses in the Netherlands: greenhouse design, operational control and decision support systems. Acta Horticulturae 718: 191-201.
Boulard, T., and A. Baille, 1995. Modelling of air exchange rate in a greenhouse equipped with continuous roof vents. Journal of Agricultural Engineering Research 61: 37-48.
Boulard, T., P. Feuilloley, and C. Kittas, 1997. Natural ventilation performance of six greenhouse and tunnel types. Journal of Agricultural Engineering Research 67: 249-266.
Coelho, J.P., M. Oliveira, and J.B. Cunha, 2005. Greenhouse air temperature predictive control using the particle swarm optimisation algorithm. Computers and Electronics in Agriculture 49(3): 330-344.
Dariouchy, A., E. Aassif, K. Lekouch, L. Bouirden, and G. Maze, 2009. Prediction of the intern parameters tomato greenhouse in a semi-arid area using a time-series model of artificial neural networks. Measurement 42(3): 456-463.
Demrati, H., T. Boulard, H. Fatnassi, A. Bekkaoui, H. Majdoubi, H. Elattir, and L. Bouirden, 2007. Microclimate and transpiration of a greenhouse banana crop. Biosystems Engineering 98(1): 66-78.
Ferreira, P.M., E.A. Faria, and A.E. Ruano, 2002. Neural network models in greenhouse air temperature prediction. Neurocomputing 43: 51-75.
Haupt, R.L., and S.E. Haupt, 2004. Practical genetic algorithms, second edition. Wiley-Interscience, New Jersey, USA: 215-219.
Kinderlan, M., 1980. Dynamic modelling of greenhouse of environment. Transactions of the ASAE 23: 1232-1237.
Kittas, C., N. Katsoulas, and A. Baille, 2001. Transpiration and energy balance of a greenhouse rose crop in Mediterranean summer conditions. Acta Horticulturae 559: 395-400.
Ntoula, E., N. Katsoulas, C. Kittas, A. Youssef, V. Exdaktylos, and D. Berckmans, 2012. Data based modeling approach for greenhouse air temperature and relative humidity. Acta Horticulturae 952: 67-72
Tavakolpour, A.R., I.Z. Mat Darus, O. Tokhi, and M. Mailah, 2010. Genetic algorithm-based identification of transfer function parameters for a rectangular flexible plate system. Engineering Applications of Artificial Intelligence 23(8): 1388-1397.
Teitel, M., G. Ziskind, O. Liran, V. Dubovsky, and R. Letan, 2008. Effect of wind direction on greenhouse ventilation rate, airflow patterns and temperature distributions. Biosystems Engineering 101: 351-369.
Young, P.C., 1984. Recursive estimation and time series analysis. Springer-Verlag, Berlin.
Youssef, A., J. Dekock, S.E. Ozcan, D. Berckmans, N. Katsoulas, and C. Kittas, 2011. Data-based approach to model the dynamic behaviour of greenhouse temperature. Acta Horticulturae 893: 931-938.
※ AI-Helper는 부적절한 답변을 할 수 있습니다.