NTIS 바로가기지질공학 = The journal of engineering geology, v.25 no.1, 2015년, pp.131 - 148
송재용 ((주)산하이앤씨) , 김기준 ((주)산하이앤씨) , 안상곤 ((주)산하이앤씨) , 김진성 (한국농어촌공사 농어촌연구원) , 정교철 (안동대학교 지구환경과학과)
The purpose of this study is to analyze and compare the heat transfer efficiency of using copper pipe, stainless pipe and traditional PE pipe commonly used for geothermal heat exchanger, with aims at seeking improved methods. In addition, the varying efficiency of heat transfer from ground heat and ...
Barbier, E., 2002, Geothermal energy technology and current status: an overview, Renewable and Sustainable Energy Reviews, 6(1-2), 3-65.
Kim, O. J., Lee, K. H., and Kim, M. S., 2008, A study on improving the efficiency of ground heat exchanger, The Korea Society of Mechanical Engineers Autumn Conference, 11, 2008, 3142-3147 (in Korean with English abstract).
Lee, M. T., Kim, Y. I., and Kang, B. H., 2007, Dynamic simulation of ground source heat pump with a vertical U-tube ground heat exchanger, Korean journal of airconditioning and refrigeration engineering, 19(5), 372-378 (in Korean with English abstract).
Lee, C. H., Lee, K. J., Choi, H. S., and Choi, H. P., 2009, Thermal conductivity and viscosity of graphite-added bentonite grout for backfilling ground heat exchanger, Transactions of the Korea society of geothermal energy engineers, 5(1), 19-24 (in Korean with English abstract).
Lee, J. Y., 2009, Current status of ground source heat pumps in korea, Renewable and Sustainable Energy Reviews, 13(6), 1560-1568 (in Korean with English).
Lund, J. W., Freeston, D. H., and Boyd, T. L., 2011, Direct utilization of geothermal energy 2010 worldwide review, Geothermics, 40(3), 159-180.
Massachusetts Institute of Technology (MIT), 2006, The future of geothermal energy, Idaho National Laboratory, 200p.
No, S. T., 2014, An analysis of borehole depth variation of vertical closed loop ground heat exchanger with various design conditions, Journal of the Regional Association of Architectural Institute of the Korea, 16(1), 233-238 (in Korean with English abstract).
Park, Y. B., Park, J. B., Lim, H. S., and Baek, S. K., 2007, Economic analsys of cooling-heating system using ground source heat in multi family apartment, Journal of the Korean Geoenvironmental Society, 8(3), 11-18 (in Korean with English abstract).
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
오픈액세스 학술지에 출판된 논문
※ AI-Helper는 부적절한 답변을 할 수 있습니다.