최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기분석과학 = Analytical science & technology, v.29 no.5, 2016년, pp.234 - 241
김종환 (안전성평가연구소 환경독성연구센터) , 권영상 (안전성평가연구소 환경독성연구센터) , 신민철 (안전성평가연구소 환경독성연구센터) , 김수정 ((주)코미팜 의약사업부) , 서종수 (안전성평가연구소 환경독성연구센터)
The approach presented in this article refers to the bioanalytical method validation for the detection and quantitative determination of arsenic species including arsenite (As(III)), arsenate (As(V)), dimethylarsinic acid (DMA) and monomethylarsonic acid (MMA) in dog plasma by high-performance liqui...
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
M. K. Paik, W. I. Kim, J. H. Yoo, J. K. Kim, M. J. Kim, G. J. Im, M. K. Hong and A. S. Om, J. Food Hyg. Safety , 25 (1), 16-23 (2010).
M. Y. Lee, B. I. Jung, S. M. Chung, O. N. Bae, J. Y. Lee, J. D. Park, J. S. Yang, H. Lee and J. H. Chung, Environ. Health Perspect. , 111 (4), 513-517 (2003).
J. Mahata, A. Basu, S. Ghoshal, J. N. Sarkar, A. K. Roy, G. Poddar, A. K. Nandy, A. Banerjee, K. Ray, A. T. Natarajan, R. Nilsson and A. K. Giri, Mutat. Res. , 534 (1-2), 133-143 (2003).
S. K. Lee, J. Y. Yang, K. W. Kim, S. Y. Lee, T. J. Kwon and Y. C. Yoo, J. Environ. Toxicol. , 18 , 101-109 (2003).
H. K. Das, A. K. Mitra, P. K. Sengupta, A. Hossain, F. Islam and G. H. Rabbani, Environ. Int. , 30 (3), 383-387 (2004).
J. W. Chen, H. Y. Chen, W. F. Li, S. H. Liou, C. J. Chen, J. H. Wu and S. L. Wang, Chemosphere , 84 (1), 17-24 (2011).
P. Bhattacharya, G. Jacks, K. M. Ahmed, J. Routh and A. A. Khan, Bull. Environ. Contam. Toxicol. , 69 (4), 538-545 (2002).
R. Bhattacharyya, D. Chatterjee, B. Nath, J. Jana, G. Jacks and M. Vahter, Mol. Cell. Biochem. , 253 (1-2), 347-355 (2003).
G. J. Jeong and D. C. Kim, Speciation analysis of arsenic species in surface water. J. Korean Soc. Environ. Eng. , 30 (6), 621-627 (2008).
O. N. Bae, M. Y. Lee, S. M. Chung, J. H. Ha and J. H. Chung, J. Environ. Toxicol. , 21 (1), 1-11 (1986).
K. Y. Song, J. H. Park, Y. J. Cho, W. K. Baek, K. Y. Kwon, H. S. Kim and C. M. Kang, Korean J. Pediatr. , 43 (3), 327-334 (2000).
E. Terlecka, Environ. Monit. Assess. , 107 (1-3), 259-284 (2005).
A. M. Featherstone, E. C. Butler, B. V. O'Grady and P. Michel, J. Anal. At. Spectrom. , 13 (12), 1355-1360 (1998).
T. Nakazato, T. Taniguchi, H. Tao, M. Tominaga and A. Miyazaki, J. Anal. At. Spectrom. , 15 (12), 1546-1552 (2000).
S. K. Shin and T. S. Kim, Anal. Sci. Technol. , 15 (2), 1-38 (2002).
S. Y. Lee, H. J. Oh, Y. H. Choi, J. W. Kim and S. H. Kim, Korean J. Lab. Med. , 24 (6), 362-370 (2004).
Kim S. R. ‘Analytical method for lead and cadmium in whole blood by inductively coupled plasma-mass spectrometry and graphite furance atomic absorption spectrometry’ Ph. D. Dissertation, Soonchunhyang University, 2008.
Kim Y. J. ‘The study on trace heavy metal analysis and arsenic speciation using ICP-MS (inductively coupled plasma-mass spectrometry)’ Ph. D. Dissertation, Korea University, 2011.
Guideline for Industry on Bioanalytical Method Validation, FDA/CDER, May 2001.
Guideline on Bioanalytical Method Validation, MFDS, Dec, 2013.
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
오픈액세스 학술지에 출판된 논문
※ AI-Helper는 부적절한 답변을 할 수 있습니다.