최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기멀티미디어학회논문지 = Journal of Korea Multimedia Society, v.20 no.3, 2017년, pp.465 - 473
김정준 (School of Electronics Engineering, Kyungpook National University) , 이승민 (School of Electronics Engineering, Kyungpook National University) , 류강수 (Dept. of Information & Communications Eng., Gumi University) , 이종학 (Dept. of Information Technology Eng., Catholic University of Daegu) , 박길흠 (School of Electronics Engineering, Kyungpook National University)
Electrocardiogram(ECG) signal is one of the unique bio-signals of individuals and is used for personal authentication. The existing studies on personal authentication method using ECG signals show a high detection rate for a small group of candidates, but a low detection rate and increased execution...
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
핵심어 | 질문 | 논문에서 추출한 답변 |
---|---|---|
심전도 신호분석에 일반적으로 사용되는 전처리 알고리즘에는 무엇이 있는가? | 심전도 신호 측정 시에 발생하는 노이즈는 기준점의 오검출을 야기한다. 따라서 심전도 신호분석에는 전처리가 선행되는데, 일반적으로 사용되는 전처리알고리즘에는 주파수 영역에서의 대역필터[20], 웨이블릿을 이용한 필터[21], 형태학적 연산 기반의 필터[22] 등이 존재한다. | |
심전도 신호 해석에서 R-peak 검출 방식에는 무엇이 있는가? | R-peak 검출 방식에는 미분신호 및 평균필터를 이용하는 방법[20], Wavelet을 이용하는 방법[21], 불응기를 이용한 적응적 탐색구간을 이용하는 방법[23] 등이 존재한다. 본 논문에서는 그 중 가장 대표적인 Pan and Tompkins의 알고리즘을 적용하여 Rpeak를 검출한다[20]. | |
생체신호를 이용한 개인인증 방식의 문제점은 무엇인가? | 그러나 이러한 생체신호들은 사고나 선천적 장애에 의해 신체일부가 훼손되거나 유실되어 생체신호를 획득할 수 없거나 변형되는 문제가 존재한다. 그 뿐만 아니라 지문과 같이 생체인증기기에 접촉할 때 발생하는 흔적을 채취하여 생체정보의 도난이 발생할 수 있으며, 콘택트렌즈나 프린트된 이미지를 통한 홍채의 위조, 녹음기를 이용한 음성위조 등의 문제가 발생한다[4] |
E.H. Holder, Jr.L.O. Robinson, and J.H. Laub, The Fingerprint Sourcebook, National Institute of Justice, Office of Justice Programs, Washington, 2011.
W.W. Boles, "A Security System Based on Human Iris Identification Using Wavelet Transform," Engineering Applications of Artificial Intelligence, Vol. 11, No. 1, pp. 77- 85, 1998.
A. Samal and P.A. Lyengar, "Automatic Recognition and Analysis of Human Faces and Facial Expressions: A Survey," Pattern Recognition, Vol. 25, No. 1, pp. 65-77, 1992.
M. Espinoza, C. Champod, and P. Margot, "Vulnerabilities of Fingerprint Reader to Fake Fingerprints Attacks," Forensic Science International, Vol. 204, No. 1-3, pp. 41-49, 2011.
S.A. Israel, W.T. Scruggs, W.J. Worek, and J.M. Irvine, "Fusing Face and ECG for Personal Identification," Proceedings of the 32nd Applied Imagery Pattern Recognition Workshop, pp. 226-231, 2003.
Y.N. Singh, S.K. Singh, and P. Gupta, "Fusion of Electrocardiogram with Unobtrusive Biometrics: An Efficient Individual Authentication System," Pattern Recognition Letters, Vol. 33, Issue 14, pp. 1932-1941, 2012.
M. Malik, "Heart Rate Variability: Standards of Measurement, Physiological Interpretation, and Clinical Use," Circulation, Vol. 93 No. 5, pp. 1043-1065, 1996.
L.D. Lathauwer, B.D. Moor, and J. Vandewalle, "Fetal Electrocardiogram Extraction by Blind Source Subspace Separation," IEEE Transactions on Biomedical Engineering, Vol. 47, No. 5, pp. 567-572, 2000.
E. Tatara and A. Cinar, "Interpreting ECG Data by Integrating Statistical and Artificial Intelligence Tools," IEEE Engineering in Medicine and Biology Magazine, Vol. 21, No. 1, pp. 36-41, 2002.
J. Carlson, R. Johansson, and B. Olsson, "Classification of Electrocardiographic PWave Morphology," IEEE Transactions on Biomedical Engineering, Vol. 48, No. 4, pp. 405-410, 2001.
M. Ohlsson, H. Holst, and L. Edenbrandt, "Acute Myocardial Infarction: Analysis of the ECG Using Artificial Neural Networks," Proceedings of the Artificial Neural Networks in Medicine and Biology-1 Conference, Vol. 4, pp. 209-214, 2000.
H.J. Jang and J.S. Lim, "Detection of Premature Ventricular Contraction Using Discrete Wavelet Transform and Fuzzy Neural Network," Journal of Korea Multimedia Society, Vol. 12, No. 3, pp. 451-459, 2009.
L. Biel, O. Pettersson, L. Philipson, and P. Wide, "ECG Analysis: A New Approach in Human Identification," IEEE Transactions on Instrumentation and Measurement, Vol. 50, No. 3, pp. 808-812, 2001.
S.M. Lee, Y.S. Jung, J.S. Kim, C.H. Ryu, W.H. Cho, D.S. Lee, et al., "Self-Organized Real- Time Authentication Mechanism Using ECG Signal," Proceeding of 2014 The International Industrial Information Systems Conference, pp. 231-233, 2014.
S. Israel, J.M. Irvine, A. Cheng, M.D. Wiederhold, and B.K. Wiederhold, "ECG to Identify Individuals," Pattern Recognition Society, Vol. 38, pp. 133-142, 2005.
Y.N. Singh and S.K. Singh, "Evaluation of Electrocardiogram for Biometric Authentication," Journal of Information Security, Vol. 3, No. 1, pp. 39-48, 2012.
Y.N. Singh and S.K. Singh, "Identifying Individuals Using Eigenbeat Features of Electrocardiogram," Journal of Engineering, Vol. 2013, Article ID 539284, 2013.
J.S. Arteaga-Falconi, H.A. Osman, and A.E. Saddik, "ECG Authentication for Mobile Devices," IEEE Transactions on Instrumentation and Measurement, Vol. 65, No. 3, pp. 591-600, 2016.
S.J. Kang, S.Y. Lee, H.I. Cho, and H.G. Park, "ECG Authentication System Design Based on Signal Analysis in Mobile and Wearable Devices," IEEE Signal Processing Letters, Vol. 23, No. 6, pp. 805-808, 2016.
J. Pan and W.J. Tompkins, "A Real-Time QRS Detection Algorithm," IEEE Transactions on Biomedical Engineering, Vol. BME-32, No. 3, pp. 230-236, 1985.
J.P. Martinez, R. Almeida, and S. Olmos, "A Wavelet-Based ECG Delineator: Evaluation on Standard Databases," IEEE Transactions on Biomedical Engineering, Vol. 51, No. 4, pp. 570-581, 2004.
K.H. Park and J.H. Kim, "Removing Baseline Drift in ECG Signal Using Morphology-Pair Operation and Median Value," Journal of The Korea Society of Computer and Information, Vol. 19, No. 8, pp. 107-117, 2014.
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
출판사/학술단체 등이 한시적으로 특별한 프로모션 또는 일정기간 경과 후 접근을 허용하여, 출판사/학술단체 등의 사이트에서 이용 가능한 논문
※ AI-Helper는 부적절한 답변을 할 수 있습니다.