NTIS 바로가기한국정밀공학회지 = Journal of the Korean Society for Precision Engineering, v.34 no.5, 2017년, pp.349 - 353
서동기 (오송첨단의료산업진흥재단 첨단의료기기개발지원센터) , 강주성 (오송첨단의료산업진흥재단 첨단의료기기개발지원센터) , 김은영 (오송첨단의료산업진흥재단 첨단의료기기개발지원센터)
Most of passive implants belong to medical device are consist of metallic and nonmetallic materials. According to the sort of components, it makes more influence into the human body. In this study, we performed induced-RF (Induced-Radio Frequency) heating evaluation which is part of MRI (Magnetic Re...
Gerber, Mark, Crawford, Neil R., Chamberlain, Robert H., Fifield, Mary S., LeHuec, Jean-Charles, Dickman, Curtis A.. Biomechanical Assessment of Anterior Lumbar Interbody Fusion With an Anterior Lumbosacral Fixation Screw-Plate: Comparison to Stand-Alone Anterior Lumbar Interbody Fusion and Anterior Lumbar Interbody Fusion With Pedicle Screws in an Unstable Human Cadaver Model. Spine, vol.31, no.7, 762-768.
Oxland, T. R., Lund, T.. Biomechanics of stand-alone cages and cages in combination with posterior fixation: a literature review. European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society, vol.9, no.1, S095-S101.
Shellock, Frank G., Spinazzi, Alberto. MRI Safety Update 2008: Part 1, MRI Contrast Agents and Nephrogenic Systemic Fibrosis. AJR : American journal of roentgenology, vol.191, no.4, 1129-1139.
National Institue of Food and Drug Safety Evaluation, Medical Device Evaluation Department, “Safety Guideline about Passive Implant at Magnetic Resonance,” http://www.mfds.go.kr/index.do?x=0&searchkey=title:contents&mid=1161&searchDivision=&searchClass=&searchword=%C0%DA%B1%E2%B0%F8%B8%ED&y=0&searchSubDivision=&pageNo=1&seq=11182&sitecode=2016-10-04&cmd=v (Accessed 21 APR 2017)
Park, S.M., Kamondetdacha, R., Amjad, A., Nyenhuis, J.A.. MRI Safety: RF-Induced Heating Near Straight Wires. IEEE transactions on magnetics, vol.41, no.10, 4197-4199.
National Institue of Food and Drug Safety Evaluation, Medical Device Evaluation Department, “Pyrogen Test of Medical Device Applied Guideline,” http://www.mfds.go.kr/index.do?x=0&searchkey=title:contents&mid=1161&searchDivision=&searchClass=&searchword=%B9%DF%BF%AD&y=0&searchSubDivision=&pageNo=1&seq=8234&sitecode=2014-08-21&cmd=v (Accessed 21 APR 2017)
ASTM F2182, “Standard Test Method for Measurement of Radio Frequency Induced Heating On or Near Passive Implants During Magnetic Resonance Imaging,” 2011.
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
※ AI-Helper는 부적절한 답변을 할 수 있습니다.