최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기大韓齒科醫師協會誌 = The journal of the Korean dental association, v.56 no.7, 2018년, pp.366 - 374
윤미정 (부산대학교 치의학전문대학원 치과보철학교실) , 김소연 (부산대학교병원 치과진료센터) , 강은숙 (인제대학교 해운대백병원 치과보철과)
Purpose : The purpose of this study was to compare the marginal fit of monolithic zirconia restorations fabricated form the conventional and the digital impression technique. Materials and methods : Ten patients were restored with monolithic zirconia restorations fabricated from the digital and the ...
Piconi C, Maccauro G. Zirconia as a ceramic biomaterial. Biomeaterials 1999;20:1-25
Koutayas SO, Vagkopoulou T, Pelekanos S, Koidis P, Strub JR. Zirconia in dentistry: part 2. Evidence-based clinical break-through. Eur J Esthet Dent 2009;4:348-80
Rinke S, Gersdorff N, Lange K, Roediger M. Prospective evaluation of zirconia posterior fixed partial dentures: 7-year clinical results. Int J Prosthodont 2013;26:164-71
Albashaireh ZS, Ghazal M, Kern M. Two-body wear of different ceramic materials opposed to zirconia ceramic. J Prosthet Dent 2010;104:105-13
Filser F, Kocher P, Weibel F, LUthy H, Scharer P, Gauckler LJ. Reliability and strength of all-ceramic dental restorations fabricated by direct ceramic machining (DCM). Int J Comput Dent 2001;4:89-106
Christensen GJ. Impressions are changing: deciding on conventional, digital or digital plus in-office milling. J Am Dent Assoc 2009;140:1301-4
Mormann WH. The evolution of the CEREC system. J Am Dent Assoc 2006;137(Suppl):7S-13S
Henkel GL. A comparison of fixed prostheses generated from conventional vs digitally scanned dental impressions. Compend Contin Educ Dent 2007;28:422-4, 426-8, 430-1
Schwartz IS. A review of methods and techniques to improve the fit of cast restorations. J Prosthet Dent1986;56:279-83
Felton DA, Kanoy BE, Bayne SC, Wirthman GP. Effect of in vivo crown margin discrepancies on periodontal health. J Prosthet Dent 1991;65:357-64
Schwartz NL, Whitsett LD, Berry TG, Stewart JL. Unserviceable crowns and fixed partial dentures: life-span and causes for loss of serviceability. J Am Dent Assoc 1970;81:1395-401
Karlsson S. A clinical evaluation of fixed bridges, 10 years following insertion. J Oral Rehabil 1986;13:423-32
Reports of councils and bureaus: Revised american national standards institute/american dental association specification No. 8 for zinc phosphate cement. J Am Dent Assoc 1978;96:121-3
Sorensen SE, Larsen IB, Jorgensen KD. Gingival and alveolar bone reaction to marginal fit of subgingival crown margins. Scand J Dent Res 1986;94:109-14
Christensen GJ. Marginal fit of gold inlay castings. J Prosthet Dent 1966;16:297-305
Ostlund LE. Cavity design and mathematics: their effect on gaps at the margins of cast restorations. Oper Dent 1985;10:122-37
McLean JW. Polycarboxylate cements: five years' experience in general practice. Br Dent J 1972;132:9-15
Gulker I. Margins. N Y State Dent J 1985;51:213-5, 217
Kydd WL, Nicholls JI, Harrington G, Freeman M. Marginal leakage of cast gold crowns luted with zinc phosphate cement: an in vivo study. J Prosthet Dent 1996;75:9-13
Sorensen JA. A standardized method for determination of crown margin fidelity. J Prosthet Dent 1990;64:18-24
Moon BH, Yang JH, Lee SH, Chung HY. A study on the marginal fit of all-ceramic crown using CCD camera. J Korean Acad Prosthodont 1998;36:273-92
Leong D, Chai J, Lautenschlager E, Gilbert J. Marginal fit of machine-milled titanium and cast titanium single crowns. Int J Prosthodont 1994;7:440-7
Molin M, Karlsson S. The fit of gold inlays and three ceramic inlay systems: A clinical and in vitro study. Acta Odontol Scand 1993;51:201-6
Laurent M, Scheer P, Dejou J, Laborde G. Clinical evaluation of the marginal fit of cast crowns-validation of the silicone replica method. J Oral Rehabil 2008;35:116-22
Rahme HY, Tehini GE, Adib SM, Ardo AS, Rifai KT. In vitro evaluation of the "replica technique" in the measurement of the fit of Procera crowns. J Contemp Dent Pract 2008;9:25-32
Holmes JR, Bayne SC, Holland GA, Sulik WD. Considerations in measurement of marginal fit. J Prosthet Dent 1989;62:405-8
White SN, Yu Z, Kipnis V. Effect of seating force on film thickness of new adhesive luting agents. J Prosthet Dent 1992;68:476-81
Reich S, Wichmann M, Nkenke E, Proeschel P. Clinical fit of all-ceramic three-unit fixed partial dentures, generated with three different CAD/CAM systems. Eur J Oral Sci 2005;113:174-9
Kunii J, Hotta Y, Tamaki Y, Ozawa A, Kobayashi Y, Fujishima A, Miyazaki T, Fujiwara T. Effect of sintering on the marginal and internal fit of CAD/CAM-fabricated zirconia frameworks. Dent Mater J 2007;26:820-6
※ AI-Helper는 부적절한 답변을 할 수 있습니다.