NTIS 바로가기한국구조물진단유지관리공학회 논문집 = Journal of the Korea Institute for Structural Maintenance and Inspection, v.24 no.1, 2020년, pp.97 - 107
김예솜 (경기대학교 일반대학원 건축공학과) , 최병정 (경기대학교 건축공학과)
In this study, finite element analysis was carried out through the finite element analysis program (ANSYS) to investigate the fire resistance of composite columns in fire. Transient heat transfer analysis and static structural analysis were performed according to ASTM E 119 heating curve and axial f...
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
Hwang, K. J., Cho, B.Y., Yeo, I. H. (2013), A Study on the Fire Resistance Performance of Reinforced Concrete Columns according to Axial Load Ratio, Fire Science and Engineering, Vol 27, No 6, pp.26-31.
Kwak, S. S., Choi B. J. (2019), An Analytical Study on Composite Beam Performance with Post-Fire Temperature Using ANSYS Program", Journal of the Korea Academia-Industrial cooperation Society, Vol 20, No 1, pp.391-400.
Hwang, J. W., Ha, S. H., Lee, Y. H., Kim, W. J., Kwak, H. G. (2015), A Numerical Model to Evaluate Fire-Resistant Capacity of the Reinforced Concrete Members, Korea Concrete Institute, Vol 25, No 5, pp. 497-508.
Kim, H. J., Hwang, H. J., Hong Gun Park, Dong Kwan Kim, Jong Min Yang(2017), Eccentric Axial Load Test of Prefabricated Composite Columns Using Bolt-connected Steel Angles, Korean Society of Steel Construction, Volume 29, Issue 3, pp.249-260.
Mao, X. , Kodur, V. K. R. (2001), Fire resistance of concrete encased steel columns under 3-and 4-side standard heating, Journal of constructional steel Research, Journal of constructional steel Research, Vol 67, No 3, pp. 270-280.
Huang, Z. F., Tan, K. H., Phng, G. H. (2007), Axial restraint effects on the fire resistance of composite columns encasing I-section steel, Journal of Constructional Steel Research, Vol 63, No 4, pp.437-447.
Huang, Z.F., Tan, K. H., Toh, W. S., Phng, G. H. (2008), Fire resistance of composite columns with embedded I-section steel Effect of section size and load level, Journal of Constructional Steel Research, Vol 64, No 3, pp.312-325.
Ellobody, E., Young, B. (2010), Investigation of concrete encased steel composite columns at elevated temperatures, Thin-Walled Structures, Vol 48, No 8, pp.597-608.
Ellobody, E., Young, B. (2011), Performance of axially restrained concrete encased steel composite columns at elevated temperatures, Engineering Structures, Vol 33, No 1, pp.245-254.
Kim, Y. S., Choi, B. J. (2019), Experimental Study on the Fire Resistance of Steel-Reinforced Concrete Column in Fire According to Load Ratio, Journal of Korean Society of Steel Construction, Vol.31, No.6, pp.463-475.
Architectural Institute of Korea Korean Building Code-Structural (KBC 2016), AIK, Korea (in Korean), pp.340-345, 2016.
Korean Agency for Technology and Standards (2014) Methods of Fire Resistance Test for Elements of Building Construction - General Requirements (KS F 2257-1: 2014), Korea.
Ellobody, E. (2007), Nonlinear behavior of concrete-filled stainless steel stiffened slender tube columns, Thin-Walled Structures, Vol 45, Issue 3, pp.259-273.
European Committee for Standardization Eurocode 2(2004): Design of Concrete Structures: General Rules and Rules for Buildings and Structural Fire Design - Part 1-2:Structural fire design, CEN(European Committee for Standardization), pp. 19-21, pp.26-29.
European Committee for Standardization Eurocode 3(2005): Design of steel structures - Part 1-2: General rules - Structural fire design, CEN(European Committee for Standardization), pp. 20-27.
Kim, H. Y., Lee, S. H., Seo, C. h. (2002), An Experimental Study on the Mechanical Behaviro of Normal Strength Concrete at High Temperature, Architectural Institute of Korea, Vol 18, No 11, pp.77-84.
European Committee for Standardization Eurocode 4(2005): Design of composite steel and concrete structures - Part 1-2: General rules - Structural fire design, CEN(European Committee for Standardization), pp.19-28.
Kim, H. Y., Seo, C. H. (2004), An Experimental Study on the Physical Properties by Compressive Strength Areas of Concrete at High Temperature, Architectural Institute of Korea, Vol 20, No 11, pp.75-82.