최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기한국방사선학회 논문지 = Journal of the Korean Society of Radiology, v.14 no.6, 2020년, pp.841 - 848
한무재 (인제대학교 의과대학 방사선종양학과) , 양승우 (인제대학교 의과대학 방사선종양학과) , 허승욱 (양산부산대학교병원 의생명융합연구소) , 배상일 (동남권원자력의학원 방사선종양학과) , 문영민 (동남권원자력의학원 방사선종양학과) , 박성광 (인제대학교 부산백병원 방사선종양학과) , 김진영 (동남권원자력의학원 방사선종양학과)
In the field of radiation therapy using photon beams and electron beams, since each patient has a different sensitivity to radiation, skin side effects may occur even at the same dose. Therefore, if there is a risk of excessive dose to the skin, a dosimeter is attached to verify whether the correct ...
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
Kry SF, Smith SA, Weathers R, Stovall M. Skin dose during radiotherapy: a summary and general estimation technique. Journal of applied clinical medical physics, Vol. 13, No. 3, pp. 20-34, 2012
L. E. Court, R. B. Tishler, A. M. Allen, H. Xiang, M. Makrigiorgos, L. Chin, "Experimental evaluation of the accuracy of skin dose calculation for a commercial treatment planning system", Journal of Applied Clinical Medical Physics, Vol. 9, No. 1, pp. 29-35, 2008. https://doi.org/10.1120/jacmp.v9i1.2792
B. Emami, J. Lyman, A. Brown, L. Coia, M. Goitein, J. E. Munzenrider, B. Shank, L. J. Solin, M. Wesson, "Tolerance of normal tissue to therapeutic irradiation", International Journal of Radiation Oncology Biology Physics, Vol. 21, No. 1, pp. 109-122, 1991. http://dx.doi.org/10.1016/0360-3016(91)90171-Y
T. A. Reynolds, P. Higgins, "Surface dose measurements with commonly used detectors: a consistent thickness correction method", Journal of applied Clinical Medical Physics, Vol. 16, No. 5, pp. 358-366, 2015. http://dx.doi.org/10.1120/jacmp.v16i5.5572
H. J. Lee, S. H. Bae, K. H. Cho, J. H. Jeong, S. I. Kwon, K. D. Lee, "Evaluations and comparisons of body surface doses during breast cancer treatment by tomotherapy and linac radiotherapy devices", Progress in Medical Physics, Vol 28, No. 4, pp. 218-225, 2017. http://dx.doi.org/http://dx.doi.org/10.14316/pmp.2017.28.4.218
K. M. Oh, M. J. Han, J. S. Kim, Y. J. Heo, K. T Kim, G. S. Cho, Y. K. Song, S. H. Cho, S. G. Heo, J. Y. Kim, S. K. Park, S. H. Nam, "Flexible X ray detector for automatic exposure control in digital radiography", Journal of Nanoscience and Nanotechnology, Vol. 16, No. 11, pp. 11473-11476, 2016. http://dx.doi.org/10.1166/jnn.2016.13533
H. Sun, B. Zhao, D. Yang, P. Wangyang, X. Gao, X. Zhu, "Flexible X ray detector based on sliced lead iodide crystal", physica status solidi (RRL) Rapid Research Letters, Vol. 11, No. 2, pp. 1-5, 2017. http://dx.doi.org/10.1002/pssr.201600397
N. E. Hartsough, J. S. Iwanczyk, E. Nygard, N. Malakhov, W. C. Barber, T. Gandhi, "Polycrystalline mercuric iodide films on CMOS readout arrays", IEEE Transactions on Nuclear Science, Vol. 56, No. 4, pp. 1810-1816, 2009. http://dx.doi.org/10.1109/TNS.2009.2023478
M. Zhong, L. Huang, H. X. Deng, X. Wang, B. Li, Z. Wei, J. Li, "Flexible photodetectors based on phase dependent PbI2 single crystals", Journal of materials chemistry. C, Materials for optical and electronic devices, Vol. 4, No. 27, pp. 6492-6499, 2016. http://dx.doi.org/10.1039/C6TC00918B
P. Andreo, Absorbed Dose Determination in External Beam Radiotherapy: An International Code of Practice for Dosimetry based on Standards of Absorbed Dose to Water (TRS 398, Vienna, Austria, 2006)
D. Wolff, F. Stieler, G. Welzel, F. Lorenz, A. M. Yasser, S. Mai, C. Herskind, M. Polednik, V. Steil, F. Wenz, F. Lohr, "Volumetric modulated arc therapy (VMAT) vs. serial tomotherapy, step and shoot IMRT and 3D conformal RT for treatment of prostate cancer", Radiotherapy and oncology: journal of the European Society for Therapeutic Radiology and Oncology, Vol. 93, No. 2, pp. 226-259, 2009. http://dx.doi.org/10.1016/j.radonc.2009.08.011
F. M. Khan, Khan's the physics of radiation therapy fifth edition. Chapter 5: interactions of ionizing radiation (Wolters Kluwer, Philadelphia, U.S.A, 1987).
K. T. Kim, Y. J. Heo, M. J. Han, K. M. Oh, Y. K. Lee, S. W. Kim, S. K. Park, "Development and evaluation of multi energy PbO dosimeter for quality assurance of image guide radiation therapy devices", Journal of instrumentation, Vol. 12, No. 4, pp. 1-10, 2017. http://dx.doi.org/10.1088/1748 0221/12/04/C04024
K. M. Oh, M. J. Han, K. T. Kim, Y. J. Heo, C. W. Moon, S. K. Park, S. H. Nam, "Development and evaluation of polycrystalline cadmium telluride dosimeters for accurate quality assurance in radiation therapy", Journal of Instrumentation, Vol. 11, No. 2, pp 1-8, 2016. http://dx.doi.org/10.1088/1748 0221/11/02/C02040
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
Free Access. 출판사/학술단체 등이 허락한 무료 공개 사이트를 통해 자유로운 이용이 가능한 논문
※ AI-Helper는 부적절한 답변을 할 수 있습니다.