최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기방사선기술과학 = Journal of radiological science and technology, v.44 no.6, 2021년, pp.629 - 633
김민준 (가천대학교 방사선학과) , 백강남 (가천대학교 보건대학원) , 김성철 (가천대학교 방사선학과)
This article is designed to look into the radiation exposure dose to each body part and the shielding effect for workers using an additional shielding to reduce their radiation exposured by scattering radiation which is generated in a space between the operating table and lead curtain during interve...
Bor D, Sancak T, Olgar T, Elcim Y, Adanali A, Sanlidilek U, et al. Comparison of effective doses obtained from dose-area product and air kerma measurements in interventional radiology. The British Journal of Radiology. 2004;77(916):315-22.
ICRP Publication 85. Avoidance of Radiation Injuries from Medical Interventional Procedures; 2000.
Radiation Protection Guidelines for Patient Dose Reduction in Interventional Radiation Procedures. Ministry of food and drug safety. 2014. [cited 2021 November 20]. Available from: https://www.mfds.go.kr/brd/m_1060/down.do?brd_iddata0011&seq12392&data_tpA&file_seq1
Miller DL. Society for Interventional Radiology. Interventional fluoroscopy: Reducing radiation risks for patients and staff. J Vasc Interv Radiol. 2009;20(7):S274.
Artschan RE, Brettle DS, Chase K, Fender A, Howells PG, Buchan S. An investigation of the radiation doses to the lower legs and feet of staff undertaking interventional procedures. Br J Radiol. 2014;87(1038):20130746.
Koenig AM, Maas J, Viniol S, Etzel R, Fiebich M, Thomas RP, et al. Scatter radiation reduction with a radiation-absorbing pad in interventional radiology examinations. Eur J Radiol. 2020;132(5):109245.
Kim KP, Miller DL, Balter S, Kleinerman RA, Linet MS, Kwon D, Simon SL. Occupational radiation doses to operators performing cardiac catheterization procedures. Health Phys. 2008;94(3):211-27.
Yoon CH, Yoon SH, Choi JG. Radiation Exposure According to Radiation Technologist' Working Departments. Journal of Radiological Science and Technology. 2008;31(3):217-22.
Nowak M, Carbonez P, Krauss M, Verdun FR, Damet J. Characterisation and mapping of scattered radiation fields in interventional radiology theatres. Sci Rep. 2020;10(1):18754.
Kim JH, Kim JS, Kim YE, Jang IH. Comparison of worker exposure dose according to pulse rate change during TACE and analysis of spatial scattering dose distribution in laboratory. Journal of Korean Society of Cardio-Vascular Interventional Technology. 2014;17(1):137-44. [cited 2021 November 20]. Available from: https://www.dbpia.co.kr/journal/articleDetail?nodeIdNODE06401740
Kim SC, Kim S. Physics of radiology. Hanmi Medical Publishing. 2009:123-126.
Jang MS, Her SB, Kim DY, Lee WS, Lee HK, Song CW. Comparison of patient's radiation dose according to whether or not collimation is used during TACE treatment. Journal of Korean Society of Cardio-Vascular Interventional Technology. 2014; 17(1):151-5. [cited 2021 November 20]. Available from: https://www.dbpia.co.kr/journal/article-Detail?nodeIdNODE06401742
Jeon ME, Lim CH, Jung HR, You IG, Hong DH, Kang BS. A Study on Radiation Exposure Dose of Operator During Interventional Radiology Procedure. Journal of Radiological Science and Technology. 2012;35(3):219-226.
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
Free Access. 출판사/학술단체 등이 허락한 무료 공개 사이트를 통해 자유로운 이용이 가능한 논문
※ AI-Helper는 부적절한 답변을 할 수 있습니다.