최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기방사선기술과학 = Journal of radiological science and technology, v.44 no.4, 2021년, pp.375 - 380
민정환 (신구대학교 방사선학과) , 정회원 (백석문화대학교 방사선학과)
This study aim was quantitative assessment of MTFs of spectrum of the square wave chart images and Coltman chart images for 0°, 1.7°, 2.2°, 2.9°, 4.1° by using chart method. In general device was AccuRay-650 (DK Medical System, Korea) used, indirect flat panel dete...
Jeong HW, Min JW, Kim JM, et al. Performance characteristic of a CsI(Tl) flat panel detector radiography system. Journal of Radiological Science and Technology. 2012;35(2):109-17.
Miyati T, Fujita H, Kasuga T, et al. Measurements of MTF and SNR(f) using a subtraction method im MRI. Physics in Medicine and Biology. 2002;47:2961-72.
Sawant A, Antonuk LE, El-Mohri Y. Slit design for efficient and accurate MTF measurement at megavoltage X-ray energies. Medical Physics. 2007;34:1535-45.
Kim JM, Jeong HW, Min JW, et al. Correction method of slit modulation transfer function on digital medical imaging system. Journal of Radiological Science and Technology. 2006;29(3):133-9.
Min JW, Jeong HW. Comparison of modulation transfer function in measurements by using edge device angle in indirect digital radiography. Journal of Radiological Science and Technology. 2019;42(4):259-63.
Ichikawa K, et al. New method of measuring presampling MTF by fourier transform of square wave chart image. Japanese Journal of Radiological Technology. 2002;58(9):1261-7.
Kunitomo H. Modulation transfer function-presampled MTF measurements by fourier analysis using square wave chart. Japanese Journal of Radiological Technology. 2009;65(11):1561-7.
Greer PB, van Doorn T. Evaluation of an algorithm for the assessment of the MTF using an edge method. Medical Physics. 2000;27:2048.
Fujita H, Tasai DY, Itoh T, et al. A simple method for determining the modulation transfer function in digital radiography. IEEE Trans Med Imaging. 1992;11(1):34-9.
Samei E, Flynn MJ, Reimann DA, et al. A method for measuring the presampled MTF of digital radiographic systems using an edge test device. Medical Physics. 1998;25:102.
IEC (International Electro-technical Commission) 62220-1. Medical electrical equipment Characteristics of digital X-ray imaging devices Part 1: Determination of the detective quantum efficiency. Geneva; 2003.
Min JW, Jeong HW, Kim SC. Evaluation of noise power spectrum characteristics by using magnetic resonance imaging 3.0T. Journal of Radiological Science and Technology. 2021;44(1):279-88.
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
Free Access. 출판사/학술단체 등이 허락한 무료 공개 사이트를 통해 자유로운 이용이 가능한 논문
※ AI-Helper는 부적절한 답변을 할 수 있습니다.