최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기Journal of Korean Tunnelling and Underground Space Association = 한국터널지하공간학회논문집, v.23 no.5, 2021년, pp.303 - 314
최순욱 (한국건설기술연구원 지반연구본부) , 강태호 (한국건설기술연구원 지반연구본부) , 이철호 (한국건설기술연구원 지반연구본부) , 김해송 (현대건설(주) 고속도로 400호선 김포-파주 2공구 현장) , 안병철 (현대건설(주) 고속도로 400호선 김포-파주 2공구 현장) , 장수호 (한국건설기술연구원 건설산업진흥본부)
With the high quality/high stiffness/high strength of segment lining, segment lining is increasingly used as the final lining of the tunnel. Precast concrete lining has higher quality and strength than field concrete. Paradoxically, this contributes to greater damage to concrete in the event of a fi...
ASTM E794-06 (2018), Standard test method for melting and crystallization temperatures by thermal analysis, ASTM, pp. 1-4.
Beard, A., Carvel, R. (2005), The Handbook of Tunnel Fire Safety, Thomas Telford Publishing, London, pp. 113-115.
Chang, S.H., Choi, S.W., Kwon, J.W., Kim, S.H., Bae, G.J. (2007), "Alteration of mechanical properties of tunnel structural members after a tunnel fire accident", Journal of Korean Tunnelling and Underground Space Association, Vol. 9, No. 2, pp. 157-169.
Choi, S.W., Chang, S.H., Kim, H.Y., Jo, B.H. (2010), "Assessment of structural fire resistance of a fireproofed immersed tunnel under tunnel fire scenarios", Journal of Korean Tunnelling and Underground Space Association, Vol. 12, No. 6, pp. 429-441.
Clement, F., Focaracci, A. (2011), "Fire protection in tunnels: requirements, solutions and case histories", Proceedings of WTC2011, Helsinki, Finland.
EN 1992-1-2 (2004), Eurocode 2: Design of concrete structures-Part 1-2: General rules-Structural fire design; Authority: The European Union Per Regulation 305/2011, Directive 98/34/EC, Directive 2004/18/EC; European Union: Brussels, Belgium, 2004, pp. 60.
Hager, I., Mroz, K., Tracz, T. (2019), "Contribution of polypropylene fibres melting to permeability change in heated concrete - the fibre amount and length effect", Proceedings of the IOP Conference Series: Materials Science and Engineering, Vol. 706, No. 1, Montevideo, pp. 012009.
ITA (2004), Guidelines for structural fire resistance for road tunnels, Working Group No. 6 Maintenance and Repair, pp. 2-4~6.
Khoury, G.A., Majorana, C.E., Pesavento, F., Schrefler, B.A. (2002), "Modelling of heated concrete", Magazine of Concrete Research, Vol. 54, No. 2, pp. 77-101.
Kodur, V.K.R., Phan, L. (2007), "Critical factors governing the fire performance of high strength concrete systems", Fire Safety Journal, Vol. 42, No. 6-7, pp. 482-488.
KS M 3016: 2011, A (2011), Testing method of the density and specific gravity for plastics (A method), Korean Standards Association, pp. 1-10.
Lee, G.P., Park, Y.T., Choi, S.W., Bae, G.J., Chang, S.H., Kang, T.S., Lee, J.S. (2012), "An experimental study on mechanical behavior of shield segment with high-strength concrete and high-tension rebar", Journal of Korean Tunnelling and Underground Space Association, Vol. 14, No. 3, pp. 215-230.
Melbye, T., Dimmock, R. (2006), "Thermal barriers and fibre concrete roles in the passive fire protection of tunnels", Shotcrete for Underground Support X, ASCE 2006, pp. 285-297.
Phan, L.T. (1996), Fire performance of high-strength concrete: a report of the state-of-the-art, NISTIR 5934, National Institute of Standards and Technology, pp. 54-56.
Ulm, F.J., Coussy, O., Bazant, Z.P. (1999), "The "Chunnel" fire. I: Chemoplastic softening in rapidly heated concrete", Journal of Engineering Mechanics, Vol. 125, No. 3, pp. 272-282.
Zeiml, M., Leithner, D., Lackner, R., Mang, H.A. (2006), "How do polypropylene fibers improve the spalling behavior of in-situ concrete?", Cement and Concrete Research, Vol. 36, No. 5, pp. 929-942.
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
오픈액세스 학술지에 출판된 논문
※ AI-Helper는 부적절한 답변을 할 수 있습니다.