최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기한국방사선학회 논문지 = Journal of the Korean Society of Radiology, v.16 no.1, 2022년, pp.61 - 66
김종언 (가야대학교 방사선학과) , 안일훈 (가야대학교 대학원 보석디자인공학과)
The purpose of this study is to derive photon energy fluence and mass energy absorption coefficient for 1 Gy of absorbed dose of water in brachytherapy using an Ir192 source. From the radiotherapy physics written by Khan, the half-value of lead for the gamma ray beam of the Ir192 source was obtained...
F. M. KHAN, The Physics of Radiation Therapy, 3rd Ed., Wolters Wluwer Co., New York, pp. 59~377, 2003.
National Institute of Standards and Technology, "NIST Measurement Services: Calibration of X-ray and Gamma-ray Measuring Instruments", NIST Special Publication 250-58, pp. 1-96, 2001.
J. E. Kim, "Quality Assurance on Dose Distribution of Ir-192 Line Source", Journal of Radiological Science and Technology, Vol. 30, No. 1, pp. 33-38, 2007.
S. C. Chen, W. L. Jong, A. Z. Harun, "Evaluation of X-ray Beam Quality Based on Measurements and Estimations Using SpekCalc and Ipem 78 models", Malaysian Journal of Medical Sciences, Vol. 19, No. 3, pp. 22-28, 2012.
A. Akkas, "Determination of the Tenth and Half Value Layer Thickness of Concretes with Different Densities", Acta Physica Polonica A, Vol. 129, No. 4, pp. 770-772, 2016. http://dx.doi.org/10.12693/APhysPolA.129.770
C. M. Ma. Chair, C. W. Coffey, L. A. DeWerd, C. Liu, R. Nath, S. M. Seltzer, J. P. Seuntjens, "AAPM protocol for 40-300 kV x-ray beam dosimetry in radiotherapy and radiobiology", Medical Physics, Vol. 28, No. 6, pp. 869-875, 2001. https://doi.org/10.1118/1.1374247
International Standard ISO 4037-1, X and gamma reference radiation for calibrating dosimetersand doserate meters and for determining their response as a function for photon energy-Part 1: Radiation characteristics and production methods, 1st Ed., ISO, pp. 1-4, 1996.
M. R. Millner, W. H. Payne, R. G. Waggener, W. D. McDavid, M. J. Dennis, V. J. Sank, "Determination of Effective Energies in CT Calibration", Medical Physics, Vol. 5, No. 6, pp. 543-545, 1978. https://doi.org/10.1118/1.594488
J. Burger, "Radioactive sources in brachytherapy", Radiology and Oncology, Vol. 37, No. 2, pp. 127-131, 2003.
J. H. Hubbell, "Photon mass attenuation and energy absorption coefficients from 1 keV to 20 MeV", The International Journal of Applied Radiation and Isotopes, Vol. 33, No. 11, pp. 1269-1290, 1982. https://doi.org/10.1016/0020-708X(82)90248-4
https://physics.nist.gov/PhysRefData/XrayMassCoef/ElemTab/z82.html
https://physics.nist.gov/PhysRefData/XrayMassCoef/ComTab/water.html
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
Free Access. 출판사/학술단체 등이 허락한 무료 공개 사이트를 통해 자유로운 이용이 가능한 논문
※ AI-Helper는 부적절한 답변을 할 수 있습니다.